    Brand Name : Kingpo
    Model Number : KP-8869C-4
    Certification : Calibration Certificate
    Price : To be Quoted
    Payment Terms : T/T
    Supply Ability : 10 sets per month
    Delivery Time : 30 working days
    • Product Details
    • Company Profile

    250VAC IEC60335-1 Flexing Test Apparatus 4 Station


    4 Station Flexing Test Apparatus


    Instrument Introduction

    1.1 Main uses

    This instrument is mainly used to test the flexural fatigue strength of AC power cords and plug leads. It is suitable for rocking motion testing of plug power cords under a certain load.

    The instrument has no-load (only measures life, does not make open circuit judgment) On-off (makes open circuit judgment), external load (also equipped with load machine, L, N line with large current and voltage load, can make open circuit judgment), internal load test function.It has the advantages of reliable detection, stable operation, and the ability to test four products of the same type at the same time. It is an ideal instrument for the laboratory and quality control department to test related performances such as plug wires and connectors.


    1.2 Design standards

    This instrument complies with IEC60335 ,UL817, IEC60884, VDE0602, GB2099 and other standards.


    1.3 Technical parameters

    No.ItemsSpecifications

    1

    Input power220VAC±10%, 50/60Hz

    2

    fuse10A/250VAC

    3

    Output Power2000W

    4

    Number of sample cores3-core

    5

    Test station4 station

    6

    FixtureCan be selected according to need

    7

    Inside0-25A

    8

    External load0-300V 0-20A

    9

    Bending angle±(5°~ 180°)

    10

    Bending accuracy±0.5°

    11

    Bending speed±(5°~90°), 5~60 times/min arbitrary setting; ±(91°~180°), 5~40 times/min arbitrary setting

    12

    Testing frequencyArbitrary setting from 1 to 999999 times (error: ±0.1 time)

    13

    Failure alarmThe buzzer alarms when the test sample line is broken, and the touch screen has a corresponding prompt

    14

    Qualification tipsThe sample to be tested bends to the set number of tests, the touch screen has corresponding prompts and warnings

    15

    Dimensions1450 X 800 X 1400 (width X depth X height)

    16

    weightAbout 300 Kg

    Installation Instructions

    2.1 Disassembly and inspection

    1. Check whether the instrument has been injured or damaged during transportation;

    2. Check whether the instrument is upside down;

    3. Check whether the specifications on the nameplate of the instrument are consistent with the order;

    4. Check whether the packing list is consistent with the actual product.

    If the above phenomenon occurs, please do not use the instrument and contact us in time.


    2.2 Safety regulations

    1. Before using the instrument, please read the manual carefully and understand the relevant safety signs and operating procedures to ensure safety.

    2. Check whether the power supply voltage is consistent with the specifications provided on the nameplate. The power supply must be well grounded.

    3. Non-professionals should not open the door or cover of the instrument to prevent electric shock.

    4. The instrument panel display cannot be scratched with sharp objects.

    5. The user must not change the circuit or parts of the instrument by himself, otherwise the quality guarantee will be invalid and suppllier will not be responsible for the consequences.


    2.3 Installation requirements

    1. The instrument should be placed on a level and stable work surface. If there is any unevenness, it should be adjusted first.

    2. The ambient temperature used by this instrument is 25±10°C, and the relative humidity is 50±30%RH.

    3. The instrument should be kept away from heat and corrosion sources.

    4. The instrument is connected to a 220V/50Hz±10% power supply with good grounding.





    Quality 250VAC IEC60335-1 Flexing Test Apparatus 4 Station for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: KingPo Technology Development Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Electrical Safety Test Equipment products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0