Sign In | Join Free | My burrillandco.com
Home > Flanges >

3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch

    Buy cheap 3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch from wholesalers
     
    Buy cheap 3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch from wholesalers
    • Buy cheap 3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch from wholesalers
    • Buy cheap 3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch from wholesalers
    • Buy cheap 3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch from wholesalers
    • Buy cheap 3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch from wholesalers

    3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch

    Ask Lasest Price
    Brand Name :
    Model Number : 3RT1054-6AP36 3RT1054-6AF36 3RT1054-1AP36
    Certification : CE UL SA
    Price : USD100-200/pcs
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 1000pcs/month
    Delivery Time : 2-5 work days
    • Product Details
    • Company Profile

    3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch

    3RT1054-6AP36 115 A 55 kW MOTOR CONTACTOR 400VAC/ DC 220-240V 2NO 2NC CONTACTOR

    Power contactor, AC-3 115 A, 55 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S6 Busbar connections Drive: conventional screw terminal

    3RT contactors, sizes S00 to S12

    Our power range:

    • Contactors for switching motors:
      • Size S00: 3RT201 up to 7.5 kW
      • Size S0: 3RT202 up to 18.5 kW
      • Size S2: 3RT203 up to 37 kW
      • Size S3: 3RT204 up to 55 kW
      • Sizes S6 to S12: 3RT10 up to 250 kW
    • Vacuum contactors for switching motors, see SIRIUS 3RT12 and 3TF6 Vacuum Contactors:
      • Sizes S10 and S12: 3RT12 up to 250 kW
      • Size 14: 3TF6 up to 450 kW

    Ratings of three-phase motors

    The quoted rating (in kW) refers to the output power on the motor shaft (according to the nameplate).

    The power rating specifications of the contactors in kW (in accordance with IEC 60947-4-1, Table G) are guide values for 4-pole standard motors at 50 Hz AC and specified voltage (e.g. 400 V AC). The actual starting and rated data of the motor to be switched must be considered when selecting the units. The motor current, motor protection device and the permissible contactor current according to the utilization category must be aligned with each other.

    Operating mechanism types

    3RT1 contactors

    The following control and/or operating mechanism versions are available in sizes S6 to S12:

    • Standard operating mechanism with economy circuit for AC and DC operation (switchover from closing coil to holding coil)
    • Solid-state operating mechanism
      Overvoltage damping of the operating mechanism coil is already integrated in the electronics for contactors with solid state operating mechanisms. The operating mechanisms are powered via a supply voltage with an operating range from 0.8 to 1.1 x Us, optionally also controlled depending on the chosen mode of operation. Alternatively, control is also possible via the separate 24 V DC control signal input. Various rated voltage ranges for AC/DC control are available.

      The following versions are available:
      • With two operating modes: Direct control or via CPU input
      • As above, but with additional remaining lifetime indicator (RLT)
      • With fail-safe PLC input for simplification of safety applications (without mode of operation selection)

    Technical data

    Product brand name SIRIUS
    Product designation Power contactor
    Product type designation 3RT1
    General technical data
    Size of contactor S6
    Product extension
    ● function module for communication No
    ● Auxiliary switch Yes
    Power loss [W] for rated value of the current
    ● at AC in hot operating state 21 W
    ● at AC in hot operating state per pole 7 W
    Power loss [W] for rated value of the current without load current share typical 5.2 W
    Surge voltage resistance
    ● of main circuit rated value 8 kV
    ● of auxiliary circuit rated value 6 kV
    maximum permissible voltage for safe isolation
    ● between coil and main contacts acc. to EN 60947-1 690 V
    Protection class IP
    ● on the front IP00; IP20 on the front with cover / box terminal
    ● of the terminal IP00
    Shock resistance at rectangular impulse
    ● at AC 8,5g / 5 ms, 4,2g / 10 ms
    ● at DC 8,5g / 5 ms, 4,2g / 10 ms
    Shock resistance with sine pulse
    ● at AC 13,4g / 5 ms, 6,5g / 10 ms
    ● at DC 13,4g / 5 ms, 6,5g / 10 ms
    Mechanical service life (switching cycles)
    ● of contactor typical 10 000 000
    ● of the contactor with added electronics-compatible auxiliary switch block typical 5 000 000
    ● of the contactor with added auxiliary switch block typical 10 000 000
    Reference code acc. to DIN EN 81346-2 Q
    Ambient conditions
    Installation altitude at height above sea level
    ● maximum 2 000 m
    Ambient temperature
    ● during operation -25 ... +60 °C
    ● during storage -55 ... +80 °C

    Main circuit
    Number of poles for main current circuit 3
    Number of NO contacts for main contacts 3
    Operating voltage
    ● at AC-3 rated value maximum 1 000 V
    Operating current
    ● at AC-1 at 400 V
    — at ambient temperature 40 °C rated value 160 A
    ● at AC-1
    — up to 690 V at ambient temperature 40 °C rated value 160 A
    — up to 690 V at ambient temperature 60 °C rated value 140 A
    — up to 1000 V at ambient temperature 40 °C rated value 80 A
    — up to 1000 V at ambient temperature 60 °C rated value 80 A
    ● at AC-2 at 400 V rated value 115 A
    ● at AC-3
    — at 400 V rated value 115 A
    — at 500 V rated value 115 A
    — at 690 V rated value 115 A
    — at 1000 V rated value 53 A
    ● at AC-4 at 400 V rated value 97 A
    ● at AC-5a up to 690 V rated value 140 A
    ● at AC-5b up to 400 V rated value 95 A
    ● at AC-6a
    — up to 230 V for current peak value n=20 rated value 115 A
    — up to 400 V for current peak value n=20 rated value 115 A
    — up to 500 V for current peak value n=20 rated value 115 A
    — up to 690 V for current peak value n=20 rated value 115 A
    — up to 1000 V for current peak value n=20 rated value 46.5 A
    ● at AC-6a
    — up to 230 V for current peak value n=30 rated value 90 A
    — up to 400 V for current peak value n=30 rated value 90 A
    — up to 500 V for current peak value n=30 rated value 90 A
    — up to 690 V for current peak value n=30 rated value 90 A
    — up to 1000 V for current peak value n=30 rated value 46.5 A

    Main models:

    3RT1054-1AF36 3RT1054-1AP36 3RT1054-1AV36 3 3RT1054-6AF36 RT1054-6AP36 RT1054-6AV36

    Product Tags:

    3RT1054-6AP36

      

    115A contactor switch

      
    Quality 3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Yueqing Richuang Automation Equipment Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Electrical Contactor Switch products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0