    Digital Portable Ultrasonic Flaw Detector UT Flaw Detector Auto Calibration

    Ask Lasest Price
    Brand Name : HUATEC
    Model Number : FD350
    Certification : ISO, CE, GOST
    Payment Terms : T/T, Paypal, Western Union
    Supply Ability : 500pcs per month
    Delivery Time : 1-4days
    • Product Details
    • Company Profile

    Digital Portable Ultrasonic Flaw Detector UT Flaw Detector Auto Calibration

    Digital Portable DAC, AVG Curves Ultrasonic Flaw Detector / UT Flaw Detector FD350 USM60 USM35


    Digital Portable Ultrasonic Flaw Detector, ultrasonic testing equopment, UT flaw detector, ultrasonic detector FD350


    Specification:

    Ranges:

    0.5 to 10,000 mm (steel) range selectable in fixed steps or continuously variable

    Material velocity:

    1,000 to 15,000 m/s,continuously variable in steps of 1 m/s and 22 selectable material velocities

    Display delay:

    From -5 to 1,000μs

    Probe delay:0 to 200 μs

    Auto calibration

    Measurement and setting of sound velocity and probe delay using two known calibration echoes (2-point calibration)

    Pulse energy

    (Spike mode)

    Low energy (70V)

    High energy(500V)

    Square wave excitation pulse (option)

    Pulse Voltage 20 to 500 V adjustable in 10 V increments

    Pulse Width Tunable from 20 to 1000 ns in 10 ns increments

    Damping:

    Low(50 ohms),:High(500 ohms),(1,000 ohms in TR mode)

    Pulse repetition frequency:20 to 1K Hz

    Frequency ranges (-3 dB):0.2 to 1 MHz,0.5 to 4 MHz,2 to 20 MHz

    Gain: 0 to 110 dB adjustable in selectable steps 0.5, 1.0, 2.0, 6.0, 12.0, user definable, and locked (step 0).

    Rectification

    Full-wave, negative half-wave, positive half-wave and RF mode

    Reject

    Linear, 0 to 90 % screen height Variable in steps of 1 %

    Monitor gates

    2 independent gates in color bar mode, start and width variable over the entire calibration range, response threshold of 5 to 95 % screen height variable in steps of 1 %,

    Alarm

    Alarm signal via LED and connectable internal horn. Alarm mode of positive logic, negative logic or DAC

    Zoom

    Expands A-scan display area for increased screen resolution.

    Magnify

    Expands area within the selected gate over the entire display range for increased A-scan resolution.


    Sound path measurement

    Digital display of sound path (projection distance, depth) between initial pulse and the first echo in the gate, or between the echoes in the two gates, with selectable echo peak, echo flank or Japanese echo flank detection.

    Amplitude display

    In % screen height,

    dB difference above gate height,

    dB difference above DAC or TCG

    dB difference above DGS curve (SDU 35X S) or ERS

    Displayed reading

    Sound path, (reduced) projection distance, depth, amplitude for every gate, user configurable at four positions of measurement line and of the zoomed display in the A-scan

    Display

    5.7 inch LED backlight TFT_LCD

    Display resolution 320 x 240 pixels

    A-scan resolution 200 x 220 pixels, 320 x 220 pixels (zoom)

    A-scan functions

    Manual or automatic A-scan freeze,

    A-scan comparison, echo dynamics

    (envelope), peak echo storage

    Data memory

    Minimum 900 datasets store instrument setups or reports including operation parameters plus A-scan, the stored datasets can be easily previewed, recalled and exported to a computer for edit and printing. Memory can be expanded up to 1900 datasets.

    DAC / TCG

    DAC (Distance Amplitude Curves) or TCG (Time Corrected Gain) with a maximum of 16 reference echoes, 4 other curves can be displayed with variable dB intervals. The dB difference between the echo and the recorded DAC curve is measured through gate A.

    JIS DAC / TCG

    JIS DAC (Distance Amplitude Curves) with a maximum of 16 reference echoes, 4 other curves can be displayed with variable dB intervals, and 2 other curves can be displayed with constant dB intervals. The dB difference between the echo and the selected DAC curve is measured through gate A. The flaw class is evaluated according to JIS Z3060-2002

    AWS D1.1

    Provides a dynamic reflector indication rating for various AWS weld inspection applications. This allows more efficient inspections by eliminating manual calculations.

    DGS (Option)

    DGS curves for single-element and dual-element probes and for all materials, sound attenuation and transfer loss correction, 4 other curves can be displayed with variable dB intervals. Backwall, side drilled hole, flat bottom hole type of the reference reflector are used. Equivalent reflector size, dB difference or height difference is evaluated simultaneously.

    Units of measurement

    mm, inch

    Communication interface

    RS232, bi-directional

    An USB adaptor cable can be provided to connect the SDU 35X to a computer that does not have RS 232 port

    Probe connections

    2 x LEMO 01 big lemo

    Dialog languages

    Chinese, German, English, French, Italian, Portuguese, Spanish, Danish, Swedish, Norwegian, Finnish, Czech, Slovenian, Romanian, Dutch, Croatian, Hungarian, Russian, Polish, Slovakian, Japanese, Serb

    Battery power

    Li-ion battery pack (6.6 Ah)

    Battery life

    12 hours with Li-ion battery pack

    Power pack charger operation

    Via an external power supply (100 to 240 VAC);

    Operating voltage

    9 VDC

    Weight

    2 kg, including batteries

    Size

    177 mm x 255 mm x 51 mm (H x W x D)


    Product Info:
    · Automated calibration Automated gain
    · Automated make video of test process and play
    · AWS D1.1, DAC/TCG, JIS DAC/TCG, AVG, DGS, A scan & B scan
    · High-speed capture and very low noise
    · Solid metal housing (IP65)
    · High contrast viewing of the waveform from bright
    · Powerful pc software and reports can be export to excel
    · Small size, light weigh model


    DAC DGS TGS


    B Scan B Scan Thickness LEG ECHO


    LEG GRID REF RF

    Main Technical Index:

    FUNCTIONS

    PARAMETERS

    Frequency

    0.2 – 20 MHz

    Detection range

    0 - 10000 mm

    Sound velocity

    100 – 20000 m/s

    Working methods

    Pulse echo, dual, and thru-transmission

    Pulse Shift

    -5 to 3400 μs in steel (dependent on range)

    Zero point of the probe

    0 – 100 μs

    Gain adjustment

    (0-110) dB, Step:0.2, 0.5, 1.0, 2.0, 6.0, 12.0, user definable(0-24), and locked

    Vertical linear error

    ≤3%

    Horizontal linear error

    ≤0.1%

    Dynamic range

    ≥40dB

    Sensitivity surplus

    ≥60dB (200mmdepth , Ф2 flat- bottomed hole )

    Communications

    Connect with computer through RS232 or USB

    The average electric yawp

    ≤20%

    Color TFT LCD

    5.25”x 3.875” (133 x 98 mm), 640 x 480 pixels VGA, color

    Gate alarm

    Wave-entering gate / wave-losing gate sound alarm, width, height, location, continuous-tuning

    Time of battery working

    7 hours

    Temperature of working

    -10°C-60°C

    Power

    220VAC, 110VDC

    Appearance size

    11.9”W x 9.9” H x 2” D (302 x 251 x 51 mm)

    Net weight

    5.5 lbs. (2.5 kg) Li-Ion Battery; 4.8 lbs. (2.2 kg) without battery


    Standard Delivery of Digital Portable Ultrasonic Flaw Detector FD350:
    Portable ultrasonic flaw detector main unit
    Operating manual
    Straight Beam probe
    Angle-beam probe(60 degree)
    Probe cable
    PC software CD
    Serial PC cable
    AC adapter/charger
    Carrying case

    Additional Accessories:
    Straight probe (5MHZ-ф20)
    Straight probe (2.5MHZ-ф20)
    Straight probe (2.25MHZ-ф20)
    Straight probe (1MHZ-ф20)
    Angle probe (4MHZ-45degree, 8*9mm)
    Angle probe (4MHZ-60degree, 8*9mm)
    Angle probe (4MHZ-70degree, 8*9mm)
    Angle probe (4MHZ-80degree, 8*9mm)
    Angle probe (2MHZ-45degree, 8*9mm)
    Angle probe (2MHZ-60degree, 8*9mm)
    Angle probe (2MHZ-70degree, 8*9mm)
    Angle probe (2MHZ-80degree, 8*9mm)
    Probe T/R (5MHz-ф20mm, focus 15mm)
    Probe T/R (2.5MHz-ф20mm, focus 15mm)
    Connection cable to probe (BNC-BNC)
    Connection cable to probe (BNC-Lemo 00)
    Connection cable to probe (Lemo 01-BNC)
    Connection cable to probe (Lemo 01-Lemo 00)
    Lithium ion battery
    Power adapter (4A/9V)
    Power Cable
    Leather case
    Test block V1
    Test block V2
    Test blocks DAC, ASME etc.

    Quality Digital Portable Ultrasonic Flaw Detector UT Flaw Detector Auto Calibration for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: HUATEC GROUP CORPORATION
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Ultrasonic Flaw Detector products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0