Sign In | Join Free | My burrillandco.com
Home > Other Chemicals >

Automatic Ethylene Oxide Residue Detector Gas Chromatograph High Precision

    Buy cheap Automatic Ethylene Oxide Residue Detector Gas Chromatograph High Precision from wholesalers
     
    Buy cheap Automatic Ethylene Oxide Residue Detector Gas Chromatograph High Precision from wholesalers
    • Buy cheap Automatic Ethylene Oxide Residue Detector Gas Chromatograph High Precision from wholesalers

    Automatic Ethylene Oxide Residue Detector Gas Chromatograph High Precision

    Ask Lasest Price
    Brand Name : HOOHA
    Model Number : HH-18
    Certification : CE/ISO/FDA
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 10set/1 month
    Delivery Time : 20Working Days
    • Product Details
    • Company Profile

    Automatic Ethylene Oxide Residue Detector Gas Chromatograph High Precision

    Gas Chromatograph

    Automatic ethylene oxide residue detector


    Instrument size: 570mm * 465mm * 465mm (length * width * height)

    Analysis item: Determination of EO residual content

    Executive Standard GBT16886. 7-2015 Biological Evaluation of Medical Devices Part 7: Residue of Ethylene Oxide Sterilization (2)


    1. Instrument introduction


    Ethylene oxide (EO) is a broad-spectrum low-temperature sterilant that can kill a variety of microorganisms at room temperature, including spores, tubercle bacillus, bacteria, viruses, and fungi. At the same time, EO is very penetrating and can penetrate micropores to reach the corresponding depth inside the product, thereby greatly improving the sterilization effect. At present, most sterile medical device manufacturers generally adopt ethylene oxide sterilization.


    2. Reference Standard


    · GB / T 16886. 7-2015 "Medical Devices Biological Evaluation Part 7: Residue of Ethylene Oxide Sterilization"

    · GB / T 14233. 1-2008 "Inspection methods for medical infusion, blood transfusion and injection equipment Part 1: Chemical analysis methods"

    · GB19083-2010 "Technical requirements for medical protective masks"


    3. Instrument features


    · Using 320x240 dot matrix 5.7-inch large-screen LCD Chinese / English display, real-time display of temperature and operating conditions of each channel, clear and intuitive content, and truly realize man-machine dialogue;

    · Power-on self-test, automatic temperature rise, wide-range self-diagnosis function, can accurately determine the fault location and alarm;

    · Six independent temperature control (vaporization chamber, capillary vaporization chamber can be independently temperature controlled), eight-step program temperature rise function;

    · Over-temperature protection function: any circuit exceeds the set temperature, the instrument automatically power off and alarm;

    · The unique vertical heating device makes the sample vaporization more reliable, minimizes the heat radiation generated by the vaporization chamber, and ensures that the temperature deviation in the oven is extremely small;

    · After intelligent fuzzy control, the door opening system can automatically track the temperature and adjust it dynamically. The damper angle can realize precise temperature control even near the room temperature;

    · Equipped with packed column head sampling, glass-lined sampling, diaphragm cleaning, capillary split / splitless sampling device, and gas sampler can be installed;

    · High-precision dual-stabilized gas circuit, four detectors can be installed at the same time;


    4. Temperature control index


    · Temperature control range: room temperature 5 ℃ ~ 400 ℃ increment 0. 1 ℃

    · Temperature control accuracy: better than±0. 1 ℃

    Program temperature increase: 8-step interstage constant temperature time 0 ~ 999min increment 0. 1min temperature increment 0. 1 ℃ heating rate: maximum 40 ℃/ min at 200 ℃ maximum 20 ℃/ min at 200 ℃


    5. The main technical indicators of the detector


    Hydrogen flame ionization detector (FID):

    · Cylinder collector structure design, quartz nozzle, extremely high response

    · Sensitivity / detection limit: Mtslx1012g / s (n-hexadecane / isooctane)

    · Baseline noise: Rns5x1014A

    · Baseline drift: Rds1x10 14A / 30min

    · Linear: z

    Flame photometric detector (FPD):

    · Detection limit: 5x1010 g sulfur / sec or 2x1010 g sulfur / sec (calculated by H, S)

    · Minimum detection amount: 0.05 ppm or 0.02 ppm (calculated as H2S) 0.1 ppm (calculated as SO, calculated)

    · Baseline drift: ≤0.2mV / h;

    · Relative root mean square error: ≤10%;

    · Incubator temperature: higher than room temperature (8 ℃ ~ 120 ℃) ± 2%;

    106 Universal Thermal Conductivity Detector (TCD):

    · Adopt semi-diffusion structure

    · The power supply adopts constant current control

    ·Sensitivity: ≥8000mVml / mg (n-hexadecane).

    · Baseline noise: ≤20uV.

    · Baseline drift: ≤100uV / 30min.

    Nitrogen and Phosphorus Detector (NPD):

    · Sensitivity: Mfs5x10 ”g / s azobenzene

    · Noise: ≤0.02mV

    · Drift: ≤0. 15mV / h

    · Imported rubidium beads, applicable residue analysis

    Miniature thermal conductivity detector:

    · Sensitivity: ≥12000mVml / mg (n-hexadecane).

    · Baseline noise: ≤15pV.

    · Baseline drift: ≤100uV / 30min.

    Zirconia detector (ZD):

    · Baseline noise: ≤0.05mV

    · Baseline drift: ≤0.2mV / 30min

    · The detection limit for hydrogen and oxygen is 0.1ul / L


    6. Host


    ConfigurationParameterQuantity
    Detector

    (1) Hydrogen flame detector (FID)

    (2) Structural design of cylindrical collector electrode, quartz nozzle, extremely high sensitivity / detection limit: Mts1x10-12g / s (n-hexadecane / isooctane)

    (3) Baseline noise: Rns5x10-14A

    (4) Line drift: Rds1x10-14A / 30min

    (5) Linearity: ≥10

    1 set
    SamplerCapillary sampling system1 set
    Chromatography column

    Special column for ethylene oxide


    1 set
    WorkstationDual Channel All Chinese1 set
    Spare partsSyringe, pressure reducing valve connector, sampling pad, sealing pad, gas line, etc.1 set

    6. Chromatography work peripheral configuration


    ConfigurationparameterQuantity

    generator

    HK-3 hydrogen generator

    Hydrogen purity: 99.999%

    Hydrogen flow: 0 ~ 300ml / min

    Flow display: LED digital display

    Working pressure: 0 ~ 0. 5MPa (set at the factory to 0.3MPa)

    Power supply: ~ 220V ± 10% 50Hz

    Power consumption: 130W

    1 set

    AK-2 air generator

    Output flow: 0 ~ 2000ml / min

    Output pressure: 0 ~ 0. 4MPa,

    System pressure: 0.55 ~ 0. 75MPa

    Voltage stability accuracy: 0. 003 MPa

    Working noise: <40Dbd (A)

    Power supply: ~ 220V ± 10% 50Hz

    Power consumption: 150W

    1 set
    40L nitrogen cylinderHigh-purity nitrogen cylinder + pressure reducing valve (self-equipped)1 set
    Autosampler (optional according to need)

    (1) 7-inch LCD touch screen, Chinese menu input, fool-free key operation

    (2) Head space bottle station: 20

    (3) Three-way independent temperature control accuracy: better than ± 0.1 ℃

    (4) Microcomputer control, PID self-tuning temperature control mode temperature control is more accurate (gift 200 head space bottles)

    1 set
    StandardEO standard solution1 set
    Computers and printersBrand Computer (Lenovo)1 set
    Quality Automatic Ethylene Oxide Residue Detector Gas Chromatograph High Precision for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Dongguan HOOHA Electrical Equipment Company Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Flammability Test Apparatus products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0