Sign In | Join Free | My burrillandco.com
Home >

BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

    Buy cheap BFEC Type Right Angle 2-1/2
     
    Buy cheap BFEC Type Right Angle 2-1/2
    • Buy cheap BFEC Type Right Angle 2-1/2
    • Buy cheap BFEC Type Right Angle 2-1/2
    • Buy cheap BFEC Type Right Angle 2-1/2
    • Buy cheap BFEC Type Right Angle 2-1/2

    BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

    Ask Lasest Price
    Brand Name : Brando
    Model Number : DMF-Z-62S
    Certification : CE
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 100000pcs per month
    Delivery Time : Negotiation
    Price : Negotiation
    • Product Details
    • Company Profile

    BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

    BFEC Type Right Angle 2-1/2'' Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S


    This valve below is DMF-Z-62S right angle type solenoid pulse jet valve with die-casting aluminum alloy body. It simplifies the connection between gas bag and blowing tube of a dust collector. It can provide stronger airflow and meet dust removing requirements.


    The high-pressure gas enters from the air inlet , enters the lower air chamber.

    1. When the pulse valve is not energized, the gas enters the decompression chamber through the impulse valve and the orifice in the constant pressure pipeline on the upper and lower shells. The valve core blocks the pressure relief hole under the action of the spring. The gas will not be discharged, so that the pressure in the decompression chamber and the lower air chamber are consistent. Under the action of the spring, the diaphragm will block the injection port, and the gas will not burst out.

    2. When the pulse valve is energized, the valve core is lifted upward by the electromagnetic force, the pressure relief hole is opened, and the gas is ejected. Due to the role of the orifice of the constant pressure pipe, the outflow speed of the pressure relief hole is greater than that of the decompression chamber. The inflow speed of the pressure pipe gas makes the pressure in the decompression chamber lower than the pressure in the lower chamber. The gas in the lower chamber lifts up the diaphragm, opens the injection port, and performs gas injection.


    Specification Of DMF-Z-62S Electromagnetic Pulse Jet Valve:

    Model NumberDMF-Z-62S
    Port SizeG2-1/2''
    Number of Diaphragm2
    KV/CV129.26/150.85
    MediaClean Air
    VoltageAC220V, C110V, C24V, DC24V
    Connection TypeThread
    Relative Humidity of Air≤85%
    Seal MaterialNBR, HNBR, FKM, EPDM, Silicone, All Available
    Body MaterialAluminum Alloy

    Overall Diemension

    DMF-Z-62S overall Dimension


    Deconstruction Diagram

    deconstruction Diagram

    Flow Direction Of DMF-Z-62S:


    Flow Direction Of DMF-Z-62S

    FAQ:

    1.During installation and commissioning

    1). The valve cannot be opened, but the pilot is operating. → Check if the airbag pressure is too low → Exclude air leaks.

    2). Some valves are not working, others are normal.→Check the valve's wiring link and solenoid coil. → Replacement of accessories.

    3). The valve cannot be closed and there is a leak, pressure cannot be established. → The inlet of the valve is installed opposite the injection port. → reassemble

    4). The valve cannot be closed and there is a leak. → Impurities are adsorbed on the diaphragm, and the iron core is stuck. →Clean the diaphragm, check whether the diaphragm is complete, check the iron core, and replace the parts in time.

    2.During use

    1). Valve closes slowly. → Diaphragm orifice blocked. →Dredge orifice.

    2). Some valves leak, the diaphragm does not close,normally opened. → Impurities are adsorbed on the diaphragm, the pilot is damaged, and the iron core is stuck. → Clean the diaphragm, check whether the diaphragm is complete, check the iron core, and replace the parts in time.

    3). The coil is hot and burned. → Power on for a long time. → Check the working condition of the control system.

    4). There is voltage but the valve is not working. → Damaged diaphragm or blocked orifice. → Replace parts in time.

    5). Low ambient temperature, the valve is leaking or cannot be opened. → Ambient temperature is too low, there is icing in the valve. → Note the valve operating temperature range.


    Welcome to your any question and inquiry!

    Quality BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Ningbo Brando Hardware Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Pulse Jet Valve products from this supplier
    Inquiry Cart 0