    Charge And Discharge Battery Testing Machine Minimum Output Current 150mA

    Ask Lasest Price
    Brand Name : KingPo
    Model Number : 100V100A
    Certification : Calibration Certificate
    Price : To be quoted
    Payment Terms : T/T
    Supply Ability : 30 sets per month
    Delivery Time : 30 working days
    • Product Details
    • Company Profile

    Charge And Discharge Battery Testing Machine Minimum Output Current 150mA

    RCDS-100V100A

    Technical Specification for battrry Charge and Discharge Equipment


    Application Scope and Function of Equipment

    1.1Scope of equipment application: Mainly used to include lithium ion batteries, lead acid batteries, nickel cadmium batteries, nickel hydrogen batteries and other batteries in the production or experiment (CircleLifeTesting) and quality control.

    1.2test contents of the support: battery cycle life test, battery capacity test, battery charging characteristics test, battery discharge characteristics test, battery charge-holding capacity test, battery charge-discharge efficiency test, battery overcharge, over-discharge rate tolerance test, etc.

    Equipment environmental requirements and technical parameters

    Power supply: AC voltage 380V ±10%, frequency:50Hz ±10%

    Ambient temperature:0-45°C

    Environmental humidity: not greater than 95% R.H (anhydrous vapor condensation)

    No strong vibrations, non-corrosive gases and inflammable and explosive gases

    Resolution: AD:16bit

    Technical parameters


    NumberModelRCDS-100V100A
    1Number of Main Channels4CH / Rack
    2output power

    Maximum power 10kW for channel operation; no time limit

    3

    output power stability

    ±(0.1%FS+0.1%RD)
    4

    Input side power quality

    power factor>99%loaded to capacity
    Total harmonic distortion rate≤5%loaded to capacity
    6Energy consumption parameters

    Standard sine wave feedback energy, high efficiency (optimum efficiency 90%)

    7

    Main Channel Working Mode

    Charging: constant current charging CC, constant voltage charging CV, constant current constant voltage charging CCCV, constant current constant voltage charging process conversion needs to achieve no impulse voltage current;

    Discharge: constant current discharge CD, constant power amplifier CP, constant resistance discharge CR, constant voltage constant current discharge

    pause n.

    Keywords Working condition test; Pulse test;

    8Main channel voltageSingle Channel Measurement Range

    0.2V-100V, with continuously adjustable intermediate values (wide test range, suitable for various battery module test requirements)

    Minimum discharge voltage7V
    precision±(0.05%FS+0.05%RD)
    Resolution1mV
    Main channel currentSingle Channel Measurement Range-200A~+200A
    Minimum output current150mA
    precision±(0.05%FS+0.05%RD)
    resolution ratio1mA
    response time<10ms

    apolegamy assist

    voltage

    Number of channels

    32

    Measurement range

    DC:0-5V

    Measurement precision

    ±(0.05%FS+0.05%RD)

    resolution ratio

    1mV

    apolegamy assist

    temperature

    number of tracks8
    Measuring Range﹣50℃~300℃
    Accuracy in measurement±1℃
    Resolution ratio0.1℃
    timeData acquisition resolution10ms
    9

    Equipment communication mode

    Support LAN communications

    Battery BMS communications

    Support CAN 2.0A, CAN 2.0B; RS485 communications

    Supports DBC import, enables data reading with BMS CAN and participates in process control

    10

    Control control program

    Support power down data protection, support for power failure, manual stop, data file succession testing, online modification of step parameters

    Safety protection conditions can be set. Parameters include: voltage lower limit, voltage upper limit, current lower limit, current upper limit temperature upper limit

    Auxiliary channel / BMS protection conditions can be set. The parameters can include: voltage upper limit, voltage lower limit, temperature upper limit, temperature lower limit, single cell pressure difference

    cycle indexMAX10000
    Programmable stepsMAX10000
    Loop nestingMaximum 10 floors

    Step Time Range

    Unlimited support for h, min, s format

    Minimum interval for data recordingTime ≥10ms, voltage ≥0.1% FS, current ≥0.1% FS, and supporting step-by-step setting of recording conditions

    Programming Features

    Each work step may have one or more exits

    11work patternConstant-current chargingBattery pack voltage, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to
    Constant-voltage chargingCurrent, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to
    Constant current and constant voltage chargingCurrent, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to
    ShelveEnd of time
    Constant-current dischargeBattery pack voltage, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to
    Constant power dischargeBattery pack voltage, current, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to
    Constant resistance dischargeBattery pack voltage, current, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to
    12

    Data presentation

    Circular listHave cycle serial number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge level average voltage, etc.

    List of processes

    There are process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc.

    Detailed list

    There are record number, system time, accumulative time, voltage, current, energy, monomer temperature1--monomer temperature n, monomer voltage 1-- monomer voltage n, monomer voltage extreme difference, etc.
    13Data exportData can be led into excel, TXT, chart file, can provide charge-discharge curve, capacity decay rate, cycle life curve, charge-discharge voltage, current, capacity-time and other ways of data analysis curve and data list
    14Data save modeThe user can customize the name and the data save path, and the data can be saved by file
    15Type of curveX coordinates: total time, charge/discharge time/capacity, number of cycles
    Y coordinates: total voltage, current, capacity, energy, monomer voltage 1-monomer voltage n, monomer temperature 1-monomer temperature n
    16Input protectionOver-voltage, over-current, lack of phase, over-temperature, protection alarm;
    Output protectionOver-voltage, over-current, short-circuit, capacity, temperature, monomer overvoltage, monomer under-voltage protection; without detecting the battery voltage, no output;
    Power-off protectionAfter the external power is cut off, the battery and the equipment are automatically disconnected to avoid the accident caused by re-powering.
    Hardware protectionPower off protection, open circuit protection, short circuit protection; battery connection back, fault protection, over-current protection, overvoltage protection, over-temperature protection, hardware overvoltage over-current protection

    Short-circuit protection

    External short circuit;
    Software protectionPower down data protection, call continuation, overvoltage over-discharge protection, over-current protection, capacity protection, over-temperature protection, voltage trend abnormal protection, current trend abnormal protection, current fluctuation abnormal protection, voltage fluctuation abnormal protection, charge voltage rise speed abnormal protection, discharge current drop speed abnormal protection, equipment communication abnormal protection, auxiliary module communication abnormal protection
    Alarm functionThe hardware has the functions of emergency cutting off switch, automatic shutdown after power off, automatic load connection and disconnection.
    17

    Cooling-down method

    Forced air cooling
    18Sampling terminalsFour-electrode sampling mode, fixture line terminal or other
    19Auxiliary Channel Collection LineAcquisition cable length adjustable according to actual situation
    20Security classificationMeet EN 60950, GB 4943 requirements
    noiseThe noise is less than 70dBA, the sound level meter used should meet the requirements of type I in IEC804, and the accuracy should be better than ±0.5dB.
    Levels of protectionIP20
    Lightning protection

    Level 2 lightning protection requirements for GB 17626

    21MaintainabilityModular structure, spare parts available for timely replacement, maintenance, free of charge during the warranty period
    22Software upgrade serviceSoftware upgrade service provided until hardware is incompatible
    23
    Optional thermostat control functionThe software supports extended function software, which can automatically control the thermostat to start and stop, and adjust the temperature and humidity

    Device specific advantages

    Energy feedback (standard sine wave feedback energy, best efficiency 90%): energy feedback type, charge and discharge two-way are energy-saving, can save a lot of electricity consumption, while saving a lot of energy energy generated by the cost of air conditioning electricity.

    CCCV charging: charging process CCCV no gap transition, no any voltage current impact. It can effectively prevent the protection action and the secondary protection action of PCB caused by the peak current of the battery due to the heat concentration of the polar ear depowdering or the micro-short circuit producing the island effect or the overshoot phenomenon.

    The current and voltage sampling stability is good and the precision is high: high precision, high dynamic range ADC/DAC unit, high voltage sampling accuracy and good long-term stability.

    IDUser management consists of three parts: permission management, role management and user management. The administrator can set administrative permissions for each functional module of the software, and set multiple user IDs according to the permissions of the operator

    DL Dynamic Load Protection Function: Effectively protects the battery in the charge and discharge, prevents the battery fire and effectively avoids the current shock caused by the loosening of the connector, and effectively protects the electronic components of the battery from being damaged by the shock current, such as MOSFET, FUSE

    Voltage clamp function: During the charging process in the battery protection action or equipment abnormal, the voltage clamp position in the safe voltage to prevent battery or battery pack protection plate damage.

    The test step can set the record condition in sections and implement the intelligent data management record.

    Support BMS CAN communication function: real-time acquisition of BMS system total voltage, total current, single core voltage, temperature and other data, and CDS voltage and current data to do synchronous comparison, set BMS voltage and current temperature and other data to meet certain conditions, the main channel steps to stop or convert, specific reading information provided by the customer related information.

    A custom set of signals is supported. The user can customize the name according to their own requirements and data records. By adding "sub-signal quantity" as the protection parameter, the protection

    Parameter can be set multiple, and the result can generate a new decision condition by calculating the operator "maximum value, minimum value, difference value, mean value,-,×," function relation

    File query: can be based on the test date, test channels, keywords and other information search related, and support data batch export

    Appearance and Structure of Equipment

    Cabinet

    Rack size (W*D*H)

    600*800*1980mm
    weight≤300kg
    Number of modules4CH / Rack
    Remark: The above picture is for reference only, subject to physical object!
    Software Testing Interface
    Software Testing Interface
    Setup interface
    Data interface
    Curve alignment interface
    Working condition simulation setup interface
    Working condition simulation data interface
    Quality Charge And Discharge Battery Testing Machine  Minimum Output Current 150mA for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: KingPo Technology Development Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Battery Testing Machine products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0