Features
◆ Wide variety of cable and connector options available
◆ Installation requires no consumables, termination tool kits or
specialized termination training
◆ Factory installed pulling eyes available
◆ Armored cable assemblies available with integral bonding wires
◆ Fully tested labeled and documented
Application
◆ 40/100G Optical Modules Connectivity
◆ Interbuilding and intrabuilding backbones for LAN Premise and
Campus applications
◆ Data center main, horizontal, zone and equipment distribution area
trunk cables
◆ Telecommunication Network
◆ Industrial&Military
Specification
1. Operating & Storage Temperature
 | Parameters | Min | Max | Unit | 
| 1 | Operating Temperature | -40 | 70 | °C | 
| 2 | Storage Temperature | -40 | 70 | °C | 
2. Optical Performance
| LC/FC/SC Connector | 
| Item | SM | MM | 
 | 1310nm/1550nm IL(dB) | 1310nm/1550nm RL(dB) | 850nm IL(dB) | 850nm RL(dB) | 
| PC | <=0.2 | >=50 | <=0.3 | >=25 | 
| APC | <=0.3 | >=60 | N/A | N/A | 
3. Geometry Parameters
| FC/LC/SC UPC | 
| Item | Pass/Fail | 
| Parameters | Min | Max | 
| FC ROC | 10.00mm | 25.00mm | 
| LC ROC | 7.00mm | 25.00mm | 
| Fiber Height | -100.00nm | 50.00nm | 
| Apex Offset | 0.00μm | 50.00μm | 
| FC/SC/LC APC | 
| Item | Pass/Fail | 
| Parameters | Min | Max | 
| ROC | 5.0mm | 12.00mm | 
| Fiber Height | -100.0nm | 50.0nm | 
| Apex Offset | 0.00μm | 50.00μm | 
| APC Angle | 7.700deg | 8.300deg | 
| Key Error | -0.500deg | 0.500deg | 
4. Connector Detail

Product Advantages
◆ We passed many quality system vertification, like ISO, RoHS; and
passed the Supplier Audition of the key account.
◆ We have a high production capacity. Standard patch cord capacity is
15,000 connectors/day and MT product capacity is 3000
connectors/day.
◆ Our testing standard is much rigorous. Every cable is tested
individually in our production line as well as 100% tested by the
QC department.
◆ Our service is qualified. We insist on responsive and knowledgeable
service to each customer.
ORC QC Process Flow Chat
FAQ
1. Q: How can you test a single mode jumper?
A: Our single mode patch cables have been tested for end-face
inspection, singlemode IL and RL testing.
2. Q: Are these cables compatible with a variety of modules?
A: Yes, LC cables can be compatible with SFP, SFP+(BIDI SFP+), XFP,
SC cables can be compatible with BIDI SFP, GBIC, X2 and XENPAK.
3. Q: What's your average lead time?
A: Our lead time is controlled within 5 working days for the
regular products. For the MT products, our capacity is 3000
connectors per day.
4. Q: Can you produce according to the samples we send you?
A: Of course, we can produce according to your samples or technical
drawings.