Sign In | Join Free | My burrillandco.com
Home > Water Heater Parts >

Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project

    Buy cheap Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project from wholesalers
     
    Buy cheap Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project from wholesalers
    • Buy cheap Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project from wholesalers
    • Buy cheap Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project from wholesalers
    • Buy cheap Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project from wholesalers
    • Buy cheap Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project from wholesalers

    Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project

    Ask Lasest Price
    Brand Name : PASSION/OEM
    Model Number : PT-SP
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 10000units/month
    Delivery Time : 7 working days
    • Product Details
    • Company Profile

    Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project


    Intelligent Controller for Centralized Hotel Resort Solar Water Heating Project


    Main Functions:

    1, Time display
    2, Water temperature display
    3, Water level display
    4, Auto mode
    5, Water level pre-setup
    6, Manual water loading
    7, Temperature controlled water loading
    8, Timing water loading
    9, Water loading when tank is lack of water
    10, Compulsive water loading
    11, Increasing Water pressure during water is loaded.
    12, Manual heating
    13, Timing heating
    14, Hot water circulation
    15, Hot water pipe insulation
    16, Low pressure protection
    17, Collector tube protection
    18, Memory protection when power is failure



    CENTRALIZED SOLAR WATER HEATING SYSTEM USER MANUAL


    PART ONE


    A. Water shortage protection.

    If the ‘actual water level’ is less than(<) the ‘start the protection at water level’ ,

    the centralized solar water heating system start the ‘water shortage protection’, all the related water pump,auxiliary heating stop the working.


    If the ‘actual water level’ is greater than or equal to (≥) the ‘stop the protection of water level’ ,

    the centralized solar water heating system stop the ‘water shortage protection’, all the related water pump,auxiliary heating restart the working.


    B. Heat exchange(the circulation between the water tank and solar collector).

    When the ‘temperature in difference ’ between the water tank and and the solar collector

    is greater than or equal to (≥) the ‘start the circulation at’ , the circulation start the working.


    When the ‘temperature in difference ’ between the water tank and and the solar collector

    is less than or equal to (≤) the ‘stop the circulation at’ , the circulation stop the working.


    Note:

    When the ‘actual tank temperature’ is greater or equal to (≥) the setting value ‘Highest temp of water tank’,

    the circulation pump will be forced to stop the working.

    In case that the actual tank temperature will be too much higher.


    C. Anti-freezing of collector pipeline

    When the temperature in the collector pipeline is less than(<) the temp of ‘Start the pipeline circulation at’,

    the circulation pump will be forced switch on for some time (It depends on the setting of ‘working time’).


    Then it stop by 3 minutes, and detect the temperature in the collector pipeline for several times,

    until the temperature in the collector pipeline is more than(>) the setting temperature.


    D. Circulation of terminal water pipeline(between the water tank and terminal water using).

    When the temperature of terminal pipeline is less than or equal to(≤) the setting temp ‘start the circulation at’,

    it start the circulation.


    When the temperature of terminal pipeline is greater than (>) the setting temp ‘stop the circulation at’,

    it stop the circulation.


    E. Anti-freezing of terminal water pipeline(between the water tank and terminal water using).

    When the temperature of terminal pipeline is less than or equal to(≤) the setting temp ‘start the circulation at’,

    it will be forced start the circulation for 5 minutes.

    It can prevent the pipeline from frost crack.


    F. Auxiliary heating.

    When the water tank temperature is less than(<) the temp of ‘start the electric heating at’,

    the electrical element start the working.


    When the water tank temperature is more than(>) the temp of ‘start the electric heating at’,

    the electrical element stop the working.


    G. Automatically water supply.

    When the ‘water level’ is less than or equal to(≤) the minimum water level ‘start the water supply at level’,

    it start the water supply.


    When the ‘water level’ is greater than (>) the maximum water level

    ‘stop the water supply at level’, it stop the water supply.


    H. Reset.

    Press the ’reset’ to restore the original factory system defaults.


    Applications


    1) Hotels, resorts, hospitals and hostels
    2) Process industry, boiler feed, laundry and canteens
    3) Agricultural sector, hatcheries and dairies
    4) Process industry, Boiler feed, Laundry and canteens
    5) Agricultural sector, hatcheries, and dairies
    6) Swimming pool heating
    7) In-process heating
    8) Health clubs (Steam / Sauna)


    Specifications


    ModlePT-NC-15PT-NC-20PT-NC-25PT-NC-30PT-NC-40PT-NC-50PT-NC-60
    Quantity of Tubes15202530405060
    Contour aperture area1.94m22.58m23.22m23.88m25.16m26.44m27.76m2
    ManifoldInner shell: 304 2BFoaming: High pressure polyurethane
    Three Target Vacuum TubeDiameter/Length: φ58mm/1800mm; High boron and silicon content 3.3; Structure:Gradual change SS-AL-Nx/Cu selective absorption coating; Vacuum Degree:P<=5*10-3;
    Anti-dust RingWhite Silicon Rubber
    Work Pressure0.05Mpa
    BracketGalvanized Steel with Plastic Coating in Black color - 0/20/30/45 degrees
    TailstockABS
    OEM ServiceLogo painting on products and package is for free (20FT,40FT,40HQ)


    Quality Intelligent Controller For Centralized Hotel Resort Solar Water Heating Project for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Solar Water Heater Controller products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0