Intrusive Transit time ultrasonic flow meter TF1100-EI is suitable for system integrators supporting projects, water resources or heating systems and network monitoring projects flow measurement, with a small size, low price, simple operation, complete output interface features.
Intrusive Transit time ultrasonic flow meter TF1100-EIprovides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
 
Long-term stability Insertion Transit Time Ultrasonic Flow Meter with data logger Features:
 
1. Spool-piece transducer for best accuracy and beter long-term stability.
2. No moving parts, no pressure drop, no maintenance.
3. The heat measurement function by configuring with paired temperature sensors.
4. High temp. Insertion tansducers are suitable for high temperature of -35℃~150℃.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s.

 

Application
 

General

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

 
 

Specifications:Transmitter

 

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Resolution 0.25mm/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
Security Keypad lockout, system lockout

 

Specifications:Transducer

 

Degree of protection IP67 or IP68 according to EN60529
Suited Liquid Temperature Std. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Transducer Size Type S Φ58*199mm
Material of transducer Stainless Steel
Pipe diameter range DN65-6000
Cable Length Std: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

Datasheet Download TF1100-EI transit-time  insertion ultrasonic flowm...
Manual Download TF-1100-EC&EI heat meter Manual.pdf

 

Packing & Delivery

 

Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output 

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

" }
Sign In | Join Free | My burrillandco.com
Home > Counters >

Data Logger Insertion Ultrasonic Flow Meter

    Buy cheap Data Logger Insertion Ultrasonic Flow Meter from wholesalers
     
    Buy cheap Data Logger Insertion Ultrasonic Flow Meter from wholesalers
    • Buy cheap Data Logger Insertion Ultrasonic Flow Meter from wholesalers

    Data Logger Insertion Ultrasonic Flow Meter

    Ask Lasest Price
    Brand Name : Lanry
    Model Number : TF1100-EI
    Certification : CE
    Price : Negotiable
    Supply Ability : 100unit/week
    • Product Details
    • Company Profile

    Data Logger Insertion Ultrasonic Flow Meter

    Long-term stability Insertion Transit Time Ultrasonic Flow Meter with data logger

    Intrusive Transit time ultrasonic flow meter TF1100-EI is suitable for system integrators supporting projects, water resources or heating systems and network monitoring projects flow measurement, with a small size, low price, simple operation, complete output interface features.
    Intrusive Transit time ultrasonic flow meter TF1100-EIprovides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
    Long-term stability Insertion Transit Time Ultrasonic Flow Meter with data loggerFeatures:
    1. Spool-piece transducer for best accuracy and beter long-term stability.
    2. No moving parts, no pressure drop, no maintenance.
    3. The heat measurement function by configuring with paired temperature sensors.
    4. High temp. Insertion tansducers are suitable for high temperature of -35℃~150℃.
    5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

    6. Wide bi-directional flow range of 0.01 m/s to 12 m/s.


    Application

    General

    ● Replacement of defective devices

    ● Support of commissioning process and installation

    ● Performance and efficiency measurement
    - Evaluation and assessments
    - Capacity measurement of pumps
    - Monitoring of regulating valves

    ● Energy efficiency audits

    Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
    Petrochemical industry
    Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
    Refrigeration and air conditioning systems
    Food , beverage and pharmaceutical industry
    Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
    Metallurgy and mining applications
    Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

    Specifications:Transmitter


    Measurement principleUltrasonic transit-time difference correlation principle
    Flow velocity range0.01 to 12 m/s, bi-directional
    Repeatability0.2% of reading
    Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
    Response time0.5s
    Sensitivity0.003m/s
    Resolution0.25mm/s
    Damping of displayed value0-99s(selectable by user)
    Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
    Power SupplyAC: 85-265V DC: 24V/500mA
    Enclosure typeWall-mounted
    Degree of protectionIP66 according to EN60529
    Operating temperature-20℃ to +60℃
    Housing materialFiberglass
    Display4 line×16 English letters LCD graphic display, backlit
    UnitsUser Configured (English and Metric)
    RateRate and Velocity Display
    Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
    Thermal energyunit GJ,KWh can be optional
    Communication4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
    SecurityKeypad lockout, system lockout

    Specifications:Transducer


    Degree of protectionIP67 or IP68 according to EN60529
    Suited Liquid TemperatureStd. Temp.: -35℃~85℃
    High Temp.: -35℃~150℃
    Transducer SizeType S Φ58*199mm
    Material of transducerStainless Steel
    Pipe diameter rangeDN65-6000
    Cable LengthStd: 10m
    Temperature Sensor

    Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%



    Packing & Delivery


    Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application


    With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.

    Delivery

    Inserted Type Ultrasonic Flow Meter With 4-20mA Output

    Standard meter: 3-7 days

    Special meter: pls contact us

    Express, by air, by sea can be optional.

    Quality Data Logger Insertion Ultrasonic Flow Meter for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Lanry Instruments (Shanghai) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Insertion Ultrasonic Flow Meter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0