    Environmental Water Quality Sensor Monitoring Submersible PH Sensor CE with accuracy ±0.1pH

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KWS-700
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal
    Supply Ability : 100
    Delivery Time : 5-8 working days
    • Product Details
    • Company Profile

    Environmental Water Quality Sensor Monitoring Submersible PH Sensor CE with accuracy ±0.1pH

    KWS-700 Online pH Sensor

    Introduction


    KWS-700 online pH sensor is used in environmental water quality monitoring, acid/alkali/salt solution, chemical reaction process, industrial production process, it can meet the requirments of online pH measurement for most industrial applications.


    Feature


    Signal output: RS-485 (Modbus/RTU protocol).
    Convenient connection to third-party equipment such as PLC, DCS, industrial control computer,general controller, paperless recording instrument or tounch screen.
    Double high-impedance differential amplifier with strong anti-interference and fast response.

    The patented pH probe, the internal reference solution oozes very slowly from the microporous salt bridge under the pressure of at least 100KPa (1Bar), and its forward bleed continues for more than 20 months. Such a reference system is very stable and the electrode life is extended by a factor of two compared to conventional industrial electrodes.
    Easy to install: 3/4 NPT pipe thread for easy submersible installation or installation in pipes and tanks.


    Technical Specifications


    ModelKWS-700
    Measuring Range0~14pH
    Accuracy±0.1pH
    Resolution0.01pH
    Temperature Range0 ~ 50℃
    Work Pressure<0.2MPa
    Temperature Compensationautomatic temperature compensation
    OutputRS-485, MODBUS protocol
    Power Supply6~12VDC ±10%
    Wetted Part MaterialPOM
    InstallationImmersion mounting
    Cable Length5 m, customizable
    Calibration MethodTwo-point calibration
    Ip GradeIP68

    Dimension



    Installation and Electrical Connection


    Installation


    Note: The sensor should not be installed upside down or horizontally when installed, at least at an angle of 15 degrees or more.


    Wiring


    a) Red line - power cord (12 ~ 24V)
    b) Black line - ground (GND)
    c) Blue line - 485A
    d) White line - 485B
    e) Bare wire - shielded wire
    After wiring is completed, it should be carefully checked to avoid incorrect connections before powering up.


    Cable specification: Considering that the cable is immersed in water (including sea water) for a long time or exposed to the air,the cable has certain corrosion resistance.The outer diameter of the cable is Φ6 mm and all interfaces are waterproof.


    Maintenance

    Use and maintenance


    When measuring the pH sensor, it should be cleaned in distilled water (or deionized water), and the filter paper should be used to absorb moisture to prevent impurities from being introduced into the liquid to be tested. 1/3 of the sensor should be inserted into the solution to be tested.
    The sensor should be washed when not in use, inserted into a protective sleeve with a 3.5 mol/L potassium chloride solution, or the sensor inserted into a container with a 3.5 mol/L potassium chloride solution.
    Check if the terminal is dry. If it is stained, wipe it with absolute alcohol and dry it. Avoid long-term immersion in distilled water or protein solution and prevent contact with silicone grease. With a longer sensor, its glass film may become translucent or with deposits, which can be washed with dilute hydrochloric acid and rinsed with water. The sensor is used for a long time. When a measurement error occurs, it must be calibrated with the meter for calibration.
    When the calibration and measurement cannot be performed while the sensor is being maintained and maintained in the above manner, the sensor has failed. Please replace the sensor.


    Standard Buffer Ph Reference Table

    The actual reading and standard of the instrument sometimes have an error of ±1 digit.


    Calibration


    Note: the sensor has been calibrated at the factory, if not exceeding the measurement error, the calibration should not be random.


    a) Zero calibration
    Use 250 mL of distilled water in a measuring cylinder,pour into a beaker, add a packet of calibration powder with pH=6.86 , stir evenly with a glass rod until the powder is completely dissolved, configure the solution with pH=6.86 , put the sensor into the solution, wait for 3 ~ 5 minutes, after the value is stable, see if the displayed value is 6.86 . If not, you need to perform zero calibration. Refer to the appendix for calibration instructions .

    b) Slope calibration
    For acidic solution: Take 250 mL of distilled water in a measuring cylinder , pour into a beaker, add a packet of calibration powder with pH=4.00 , stir evenly with a glass rod until the powder is completely dissolved, and configure the solution topH=4.00 ; In the solution, wait for 3 to 5 minutes. After the value is stable, see if the value is 4.00 . If not, the slope calibration is required. Refer to the appendix for the calibration instructions.


    For alkaline solution: Take 250 mL of distilled water in a measuring cylinder , pour into a beaker, add a packet of calibration powder with pH=9.18 , stir evenly with a glass rod until the powder is completely dissolved, and configure the solution to pH=9.18 ; Into the solution, wait for 3 to 5 minutes. After the value is stable, see if the display is 9.18 . If not, the slope calibration is required. Refer to the appendix for the calibration instructions.


    Quality assurance


    Quality inspection departments have standardized inspection procedures, with advanced detection equipment and instruments, and in strict accordance with the test procedures for products that do 72 hours aging test, stability test, not asubstandard products factory.

    The receiving party directly returns the product batch with a failure rate of 2% , and all the costs incurred are borne by the supplier. The reference standard refers to the product description provided by the supplier.

    Guarantee the quantity of goods and the speed of shipment.


    Service commitment


    The company provides local after-sales service within one year from the date of sale, but does not include damage caused by improper use. If repair or adjustment is required, please return it, but the shipping cost must be conceited. Damaged on the way, the company will repair the damage of the instrument for free.

    Appendix data communication


    1. Data Format

    The default data format for Modbus communication is: 9600, n, 8, 1 (baud rate 9600bps, 1 start bit, 8 data bits, no parity, 1 stop bit).
    Parameters such as baud rate can be customized.


    2. Information Frame Format

    a) Read data instruction frame
    06 03 xx xx xx xx xx xx
    Address Function code Register address Number of registers CRC check code (low byte first)
    b) Read data response frame
    06 03 xx xx...... xx xx xx
    Address Function code Bytes Answer data CRC check code (low byte first)
    c) Write data instruction frame
    06 06 xx xx xx xx xx xx
    Address Function code Register address Write data CRC check code (low byte first)
    d) Write data response frame (same data command frame)
    06 06 xx xx xx xx xx xx
    Address Function code Register address Write data CRC check code (low byte first)


    3. Register Address

    Note:
    a) Modbus register address according to the protocol defined with the register type register start address (16 hex represents the actual starting address register in parentheses).
    b) When changing the sensor address, the sensor address in the return command is the changed new address.
    c) The data definition that returns the measured value when reading data:
    xx xx xx xx xx xx Xx xx

    2- byte measurement 2 bytes measurement value scale number 2 bytes temperature value 2 bytes temperature scale


    The data type defaults to: double-byte integer, high byte first; others are optional as floating-point types.
    4. Command example

    a) Read data instruction:
    Function: Obtain the pH and temperature of the measuring probe; the unit of pH is pH; the unit of temperature is °C.
    Request frame: 06 03 00 00 00 04 45 BE ;
    Response frame: 06 03 08 00 62 00 02 01 01 00 01 24 59


    Example of reading:


    pH: 00 62 indicates the hexadecimal reading pH value, 00 02 indicates that the pH value has 2
    decimal places and is converted to a decimal value of 0.98 .
    Temperature value: 01 01 indicates the hexadecimal reading temperature value, 00 01 indicates that
    the temperature value has 1 decimal place and is converted to a decimal value of 25.7 .


    b) Calibration instructions:

    Zero calibration
    Function: Set the pH zero calibration value of the electrode. The zero value is based on the 6.86 pH standard. The examples are as follows
    Request frame: 06 06 10 00 00 00 8C BD
    Response frame: 06 06 10 00 00 00 8C BD
    Slope calibration
    Function: Set the pH slope calibration value of the electrode; the slope calibration is divided into high point and low point calibration, and the alkaline solution is measured at the high point; the acidic solution is measured at the low point, where the standard solution is high here.
    point 9.18pH, low 4.00pH standard solution of the calibration reference, examples are as follows:
    High point standard solution 9.18 pH calibration:
    Request frame: 06 06 10 04 00 00 CD 7C
    Response frame: 06 06 10 04 00 00 CD 7C
    Low standard solution 4.00 pH calibration:
    Request frame: 06 06 10 02 00 00 2D 7D
    Response frame: 06 06 10 02 00 00 2D 7D


    c) Set the device ID address:

    Role: set the MODBUS device address of the electrode;
    Change the device address 06 to 01. The example is as follows
    Request frame: 06 06 20 02 00 01 E3 BD
    Response frame: 06 06 20 02 00 01 E3 BD


    5. Error response

    If the sensor does not execute the host command correctly, it will return the following format information:

    a) CODE : 01 – function code error
    03 – data is wrong
    b) COM : Received function code


    Company Information



    Xi'an Kacise is certified by ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof, etc. which assure our products are conform to the international standards.
    We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. We have experienced technical and management personnel, through the efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.
    Currently, Kacise sensor is already exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regards “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.














































    Quality Environmental Water Quality Sensor Monitoring Submersible PH Sensor CE with accuracy ±0.1pH for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Water Quality Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0