24V DC DMF-Y-50S 2'' SBFEC Type Manifold Mount Pulse Valve Full Immersion Nitrile Diaphragm
YouTube video of DMF-Y-50S SBFEC Type Manifold Mount Pulse Valve:
Technical parameters of SBFEC Type Full Immersion Diaphragm Valves
| Model | DMF-Y-25 | DMF-Y-40S | DMF-Y-50S | DMF-Y-62S | DMF-Y-76S | DMF-Y-102S |
Diaphragm size (φ66 smaller) | φ96 | φ112 | φ160 | φ188 | φ202 | φ255 |
| KV/CV value | 26.16/30.53 | 45.82/53.47 | 61.24/71.47 | 129.26/150.85 | 159.95/186.66 | 268.29/313.09 |
| Blowing area (㎡) | 8-10 | 12-16 | 18-28 | 27-38 | 37-65 | 70-90 |
| Port size | G1'' | G1 1/2'' | G2'' | G2 1/2'' | G3'' | G4'' |
| Weighgts (kg) | 0.75 | 1.2 | 2.35 | 3.2 | 4.05 | 5.65 |
| Working pressure | 0.2MPa-0.6MPa | |||||
| Environment temperature | -25℃-60℃ | |||||
| Relative humidity | ≤85% | |||||
| Working medium | Compressed air | |||||
| Protection class | IP 65 | |||||
| Service life | Over 1000000 times | |||||
| Voltages | DC24V, AC110V, AC220V | |||||
Tips: All related accessories are also sold, like Pulse Controller, Diaphragm, Solenoid Coil and Armature Assembly.
Main dimension of DMF-Y-50S 2 Inch SBFEC Type Solenoid Pulse Valve:

Details of SBFEC Type DMF-Y-50S Dust Collector Pulse Jet Valve:

100% Testing of Brando's Pulse Jet Valves:
1. Voltage test when turned on
In the air inlet of the electromagnetic pulse valve, connect the
clean air with the nominal pressure of the air source. Input the
electric signal of 85% of the nominal voltage and 0.03s of the
width on the electromagnetic valve to check whether the
electromagnetic pulse valve is open normally.
2. Air pressure test when closed
In the air inlet of the electromagnetic pulse valve, connect the
clean air with a pressure of 0.1 MPa, input the electrical signal
to close the valve, and check whether the electromagnetic pulse
valve is reliably closed.
3. Pressure resistance test
In the air inlet of the electromagnetic pulse valve, the clean air
with a pressure of 0.8 MPa is connected for 60 minutes, and the
leakage of the sealing parts on the electromagnetic pulse valve is
checked.
4. Insulation resistance test
(1) Measure the insulation resistance of the electromagnetic coil
to the outer casing under the specified environmental conditions
using a 500V meter with a range of 0MΩ to 500MΩ and an accuracy of
1 meter.
(2) Put the valve in the temperature regulation and humidity
control box, and set the temperature to 35 degrees, and the
relative humidity is 85%, apply a 50Hz, 250V sinusoidal AC voltage
between the electromagnetic coil and the valve body for 1min. Check
for breakdown.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
|