    Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight

    Ask Lasest Price
    Brand Name : TYHD
    Model Number : TYHD-AI9
    Certification : type test report
    Price : Negotiation
    Payment Terms : TT,LC,westunion
    Supply Ability : 3000 sets/month
    Delivery Time : within 3-5 working days
    • Product Details
    • Company Profile

    Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight

    Safety criterion

    Welcome to use remote transmission unit manufactured by us. Each remote terminal uint has already experienced the complete assembly, test and inspection, also the careful check and adjustment before delivery, which has been in good condition when transport.


    Device description

    Remote terminal uint is the data acquisition and communications forwarding device for power distribution network load monitoring, fault detection and positioning system, which can be set as the practical distribution terminal device of two remote (remote signaling, telemetry) functions in the distribution automation system via terminal parameter configuration, which can also be set as the traditional distribution terminal device of remote fault positioning system.

    Remote terminal uint is to process and analyze the information from overhead indicator sent via wireless and then send the circuit load current and fault information to the main distribution network station via GSM short messages or GPRS communication.


    Working principle

    Remote terminal uint is to receive the circuit fault information and circuit load operation information from overhead indicator installed in the circuit via wireless for analysis and compiling and then sends the information to main distribution network station via GPRS/GSM communications, to realize the online monitoring, fault detection and positioning functions of distribution network.


    GSM or GPRS forwarding

    GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.


    Remote upgrade

    The equipment program can be upgraded conveniently through master remote maintenance station.

    Work mode setting

    The terminal can be in the two-remote or one-remote working mode by setting the intrinsic parameters of remote terminal uint.

    Two-remote working mode: the terminal is online in real time, and the circuit load current and circuit status can be uploaded.

    One-remote working mode: the terminal is online regularly; when the circuit breaks down, the terminal opens GPRS module power supply and sends the fault information to main distribution network station.

    The equipment cover is opened

    Technical parameters

    Dimension of repeater stationH×W×T=388mm×366mm×368mm
    Weight of repeater station6.75kg
    Applied voltage grade7~69kV overhead line
    Circuit load current0~630A
    Rated working voltage5.5V-7.5V
    Overall power consumption<0.4W
    Work time in rainy weather≥10 days
    Solar panelOrganic glass protection, amorphous silicon, and 30 years of service life
    Power of solar panel12W/10V
    Quantity of cooperation indicators12
    GPRS moduleE-GSM/GPRS 900/1800 dual band
    Working temperature range (lead-acid battery)-35℃~75℃
    Working temperature range (lithium iron phosphate)-20℃~75℃
    MTBF>5×104 h

    Remote Transmission Unit


    Quality Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Beijing Tianyihongda Science & Technology Development Co., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Fault Path Indicator products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0