Sign In | Join Free | My burrillandco.com
Home > General Industrial Equipment Stock >

Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator

    Buy cheap Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator from wholesalers
     
    Buy cheap Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator from wholesalers
    • Buy cheap Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator from wholesalers
    • Buy cheap Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator from wholesalers
    • Buy cheap Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator from wholesalers
    • Buy cheap Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator from wholesalers

    Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator

    Ask Lasest Price
    Brand Name : Skymen
    Model Number : JP-1006I
    Certification : SGS, FCC, CE, RoHS, ISO9001
    Price : Negotiation
    Supply Ability : 8000 pcs per month
    Delivery Time : In Stock
    • Product Details
    • Company Profile

    Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator

    Immersible Ultrasonic Transducers Plate/Box


    Features:

    • More convenient for operation
    • Stainless steel tank has resistance to wear and long work life.
    • Can be moved to any tank
    • Controlled by generator
    • Use just tab water, or industrial solvent cleaner for more higher cleaning requirement

    JP-1006I product specification:

    ModelJP-1006I
    Box Size305*205*100mm
    Transducers6pcs
    Ultrasonic Power300W
    Frequency28KHz / 40KHz
    G.W5.3KG

    How to Use an Ultrasonic Cleaner for Medical & Surgical Instruments


    Medical and surgical instruments in a variety of sizes and complexity can pose challenges when it comes to cleaning, disinfecting and sterilizing them after use. An ultrasonic cleaner is an ideal tool for the first step in this three step process to protect medical personnel and patients from possible infection due to pathogens that remain on the instruments after a procedure.


    Suggested Ultrasonic Cleaning Procedure

    In all cases manufacturers’ instructions should be followed when using an ultrasonic cleaning process. These are representative steps.

    Fill the ultrasonic cleaning tank with an approved medical instrument cleaning solution such as CLN-LR012 available from Tovatech following dilution instructions provided. Turn the cleaner on to start the degassing process. This step removes entrained air in new solutions that interferes with the efficiency of cavitation and takes approximately 10 minutes.

    In the meantime:

    • Segregate instruments by alloy or composition to avoid potential damage (Chromium plated instruments should not be cleaned ultrasonically)
    • Instruments with movable parts should be disassembled to facilitate cleaning
    • Place the instruments the ultrasonic cleaner’s mesh basket, taking care that they do not come in contact with each other
    • Cannulated or lumened instruments should be positioned to insure interiors are wetted with the cleaning solution. In some instances placing them on an angle will facilitate this
    • Set the control panel per manufacturers’ instructions and start the cleaning process

    At the end of the cycle, remove the instruments from the ultrasonic cleaning bath and thoroughly rinse them to remove all traces of the cleaning solution. Deionized water rinses will avoid spotting. If the instruments are not to be immediately disinfected and sterilized be certain that they are thoroughly dried and protected. Part reassembly can occur after sterilization.

    Procedures should be in place to guide the replacement of used ultrasonic cleaning solutions. In some instances it is recommended that solution be drained and tanks thoroughly cleaned and dried after each ultrasonic cleaning cycle. Most solutions available today are biodegradable, which facilitates disposal but local authorities should be consulted on proper practices.


    The ultrasonic cleaner uses ultrasonic waves (vibration) using water with detergents or enzymatic products to break up soil and organic material on medical instruments/devices. These devices are rinsed then autoclaved (sterilized). The autoclave sterilizer uses heat, steam, and pressure to kill all pathogenic microorganisms and their spores.


    Package Includes:
    1 x Ultrasonic Transducers Plate
    1 x Generator
    1 x Manual


    Clean effect:


    Quality Engine Block 300W High Power Ultrasonic Transducer 40/28KHz with Generator for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Skymen Technology Corporation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Submersible Transducer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0