    Random Vibration Testing Equipment Continuous Displacement 100 mm

    Ask Lasest Price
    Brand Name : Haida
    Model Number : HD-G826
    Certification : ISO
    Price : Negotiable
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow
    Supply Ability : 300 Sets per Month
    Delivery Time : 20 days after order confirmed
    • Product Details
    • Company Profile

    Random Vibration Testing Equipment Continuous Displacement 100 mm

    Electromagnetic Shaker Vibration/ Vibration Shaker Testing Machine


    Introduction:

    The random vibration test of the shaker (GB/ t2423.56-2006) is excited by a random input signal that includes all frequency components within the specified frequency range (broadband) at all times.Its instantaneous value obeys normal (gaussian) distribution.The distribution in the frequency range is represented by the acceleration spectral density (ASD) curve.

    Random vibration is the most common type of excitation occurring in the real world.Its future instantaneous value cannot be predicted by its past state, but can only be predicted based on probability.In fact, these characteristics are applicable to most calculations related to random vibration, such as fatigue and alternating stress.

    Unlike the sinusoidal test, the random vibration of the test bed is always excited and resonant in the duration, although it cannot reach the maximum value.Most of the random signals in the laboratory have a 3 times RMS, which means that the instantaneous value of excitation within the test frequency range can be extended from zero to 3 times the total RMS (R.M.S.).The larger difference to be taken into account for the random excitation is that there will be a large number of stress alternations, both positive and negative, between the crossing points.This property will affect fatigue damage and thus the expected life of failure.

    No matter sinusoidal vibration or random vibration, only with a better understanding of the product's production, transportation, use environment and the properties and characteristics of the test equipment, can we more properly choose our own appropriate vibration mode, so as to screen high-quality products and improve the performance of defective products.


    Electro-dynamic Vibration Testing System Performance Data Sheet:


    Shaker (Model# EDM-2000)
    Sine force (peak)30kN
    Shock force (peak)60 kN
    Frequency range5~2,600 Hz
    Displacement (continuous)100 mm
    Max. Velocity1.8 m/s
    Max. Acceleration75 G
    Armature Diameter445 mm
    1st order resonant frequency2,400 Hz
    Allowable eccentric moment>500 Nxm
    Armature weight40 kg
    HE/ST screw dimensionM10 (metric)
    Axial vibration isolation frequency<3 Hz
    Max. Payload500 kg
    Magnetic flux leakage≤1 mT
    Dimensions (L×W×H, unpacked)1,330x860x1,250 mm
    Weight (unpacked)2,500 kg
    InstallationRubber mat (anchor bolts required)
    Power Amplifier (Model# VSA-H323A)
    Amplifier output30 kVA
    SNR>65 dB
    Rated output voltage120 Vrms
    Amplifier efficiency> 90%
    Dimensions (L×W×H, unpacked)800x900x2,100 mm
    Weight (unpacked)500 kg
    Blower (Model# PBL-W30)
    Air volume0.46 m3/s
    Power7.5 kW
    Air duct diameter200 mm
    Air pressure8.8kPa
    InstallationAble to connect to ceiling (up to two 90 degree bends), max 20’ run
    Horizontal Slip Table (Model# 30ST-600M)
    Dimensions600x600 mm
    Thickness45 mm
    Frequency limit2,000 Hz
    Effective mass54 kg

    Note:

    1. High pressure oil-film bearing is used for better uniformity.

    Vibration Controller and Accelerometer
    Vibration Controller VT-9008-44 Channel Vibration Controller with Sine and Self Calibration.
    Accelerometer EA-YD-181100mV/g, Range: 50g, Working Freq.: 1-10kHz, Weight: 11gram, with 10ft low noise cable
    Other supported functions/accessories
    Environmental chambersSupported
    Mobile devicesCustomizable
    Insulation boardsCustomizable
    FixtureCustomizable
    Working environment of the system
    Temperature range0-40℃
    Humidity range0~90% , no condensation
    Power requirements380V/3ph/50Hz, 40kVA
    Compressed air pressure0.6 Mpa

    How to use IT:

    1, the control manual to complete the procedure

    2, such as Operation error so that can not work, you can use the recovery method of the steps of the input, and then set a single group or other running steps.

    3, before use to press the external start switch, appears COO namely lets go, opens the key.

    4, Taiwan Body:

    1 The table body foot sleeve as far as possible fixed

    2 power supply on/work in the output line can not be unplugged

    3 Place the level as far as possible

    4 components can be changed, the line should not be changed or from the connection.

    5 The Taiwan body must not be all or part of the reorganization, only according to specifications for a single component and with the original confirmation password.

    5, the amplitude inside the code

    1. Do not adjust too large before or after the boot

    2) low-key amplitude of high amplitude modulation

    3 Control Panel Amplitude Knob placed in the middle position test items: placed to focus on the main point, reduce the left flat right.

    4 control Box: Can not be placed on the top or underground operation

    6, Inside Code:reset when running or operating incorrectly

    7, Control Box:

    1) The connecting line of the body must be locked tightly after hanging

    2 the vibration direction switch and the output connection line are correspondence, can not connect the wrong

    8, testing: Non-special test should use full wave test

    9, the Taiwan body: can not produce the collision sound, the upper and lower center axis mutual touch will cause the spring steel piece rupture to be immediately shut down, amplitude modulation is adjusted small then turns on.

    10, other unknown:

    Do not arbitrarily change internal components and lines

    11, the reason is bad:

    1 The use of computer models can not be used for shaking table control

    2 can not reload the driver

    2, for the Ista-ia test, the operator to protect the sample, to prevent the test pieces slide out of the table

    Electro-dynamic Vibration Testing System Images
    Quality Random Vibration Testing Equipment Continuous Displacement 100 mm for sale
    Company Info.
    Hai Da Labtester
    Verified Supplier
    View Contact Details
    Product List
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Hai Da Labtester
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Vibration Shaker Table Systems products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0