Sign In | Join Free | My burrillandco.com
Home >

Cu Conductor Power cable LZSH Halogen Free Flame Retardant Cables DJX cable WDZ-YJY Cable N2X2Y 4 Core

    Buy cheap Cu Conductor Power cable LZSH Halogen Free Flame Retardant Cables DJX cable WDZ-YJY Cable N2X2Y 4 Core from wholesalers
     
    Buy cheap Cu Conductor Power cable LZSH Halogen Free Flame Retardant Cables DJX cable WDZ-YJY Cable N2X2Y 4 Core from wholesalers
    • Buy cheap Cu Conductor Power cable LZSH Halogen Free Flame Retardant Cables DJX cable WDZ-YJY Cable N2X2Y 4 Core from wholesalers

    Cu Conductor Power cable LZSH Halogen Free Flame Retardant Cables DJX cable WDZ-YJY Cable N2X2Y 4 Core

    Ask Lasest Price
    Brand Name : DONGJIAXIN
    Model Number : WDZ-YJV
    Certification : IEC, Rosh,CCC
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 100KM/Week
    Delivery Time : 7-15 working days
    • Product Details
    • Company Profile

    Cu Conductor Power cable LZSH Halogen Free Flame Retardant Cables DJX cable WDZ-YJY Cable N2X2Y 4 Core

    WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor

    Fire resistant cable Applications

    These power cables are used for electricity supply in low voltage installation system. They are well adapted to underground use in industrial applications with an additional mechanical protection.These cables can be fixed on cable trays, within conduits or fixed to walls.

    Used in energy networks refineries, mines, hotels, schools, tunnels, high constructions, hospitals, power plants, data processing centers, business centers where there is a risk of fire


    Fire resistant cable Construction

    1. Conductors

    The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
    2. Insulation

    XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
    3. Assembly / Inner Covering
    4. Armour

    Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
    5. Outer Sheath

    Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
    6. Fire Performance of Cable Sheaths

    Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

    Keywords: #Cable #Wire #Wireandcable #Electricalcable #Flexiblecable #XLPEcable #LANcable #Controlcable #LSZHcable #DJXcable #Cablemanufacturer #Cablefactory #Cablesupplier #Cableprovider #Cablewholesale #Rubbercable #Powercable #Solarcable

    Product type Conductor structure(mm) Insulation thickness(mm) Sheath thickness(mm) Approx. cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
    1×1.5 1 0.8 1.4 5.2 12.1
    1×2.5 1 0.8 1.4 5.6 7.41
    1×4 1 1.0 1.4 6.0 4.61
    1×6 1 1.0 1.4 6.5 3.08
    1×10 7 1.0 1.4 7.6 1.83
    1×16 7 1.0 1.4 8.6 1.15
    1×25 7 1.2 1.4 10.2 0.727
    1×35 7 1.2 1.4 11.2 0.524
    1×50 10 1.4 1.4 12.5 0.387
    1×70 14 1.4 1.4 14.3 0.268
    1×95 19 1.6 1.5 16.5 0.193
    1×120 24 1.6 1.5 18.2 0.153
    1×150 30 1.8 1.6 20.1 0.124
    1×185 37 2.0 1.7 22.2 0.0991
    1×240 48 2.2 1.8 24.9 0.0754
    1×300 61 2.4 1.9 27.5 0.0601
    1×400 61 2.6 2.0 30.8 0.0470

    INSTALLATION METHOD DETAILS

    WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 0 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 1 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 2 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 3
    A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
    WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 4 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 5 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 6 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 7
    B1 – Electroduct in brickwork (Single-core) B1 – Electroduct in brickwork (multi-core) C – On the wall  C – On the ceiling
    WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 8 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 9 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 10 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 11
    C – Non-perforated tray F – Perforated tray (Single-core) F – Perforated tray (multi-core) F –Suspended (Single-core)
    WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 12 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 13 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 14 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 15
    E – Suspended (multi-core) B2 – Construction space B2 – Construction space B1 – Electroduct (Single-core)
    WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 16 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 17 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 18 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 19
    B2 – Electroduct (Multi-core) B2 – Closed raceway embedded in floor (multi-core) B2 – Closed raceway embedded in floor (multi-core) B1 – Ventilated raceway embedded in floor
    WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 20 WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 21
    C – Embedded in the brickwork D – Buried in additional mechanical protection

    * Dimensions and specifications may be changed without prior notice.

    Standards&Certificates:
    International: IEC 60502-1
    National:GB/ T 12706.1-2008

    Packing&Delivery:

    We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
    Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

    Copper Cable ZR YJV22 0.6/1kv XLPE Insulated Steel Tape Armoured FR PVC Underground Power Cable
    ▼ Cable Drum Data:

    CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
    Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 4 1000 700 500
    1100 700 550
    1200 700 600
    1400 750 710
    1600 900 900
    1800 1120 1000
    2400 1150 1300

    ▼ Delivery Port :

    Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 5 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 6 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 7
    Port of Shenzhen Port of Hongkong

    Port of Guangzhou

    ▼ Technical parameters:

    1. Single Core

    Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
    1×1.5 1 0.7 1.4 6.0 12.1
    1×2.5 1 0.7 1.4 6.4 7.41
    1×4 1 0.7 1.4 6.9 4.61
    1×6 1 0.7 1.4 7.3 3.08
    1×10 7 0.7 1.4 8.4 1.83
    1×16 7 0.7 1.4 9.4 1.15
    1×25 7 0.9 1.4 11.0 0.727
    1×35 7 0.9 1.4 12.0 0.524
    1×50 10 1.0 1.4 13.3 0.387
    1×70 14 1.1 1.4 15.1 0.268
    1×95 19 1.1 1.5 17.3 0.193
    1×120 24 1.2 1.5 19.0 0.153
    1×150 30 1.4 1.6 20.9 0.124
    1×185 37 1.6 1.6 23.0 0.0991
    1×240 48 1.7 1.7 25.7 0.0754
    1×300 61 1.8 1.8 28.3 0.0601
    1×400 61 2.0 1.9 31.6 0.0470
    1×500 61 2.2 2.0 35.1 0.0366
    1×630 61 2.4 2.2 42.1 0.0283

    2. 2 Core&3 Core

    Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
    2×1.5 1 0.7 1.8 10.6 12.1
    2×2.5 1 0.7 1.8 11.4 7.41
    2×4 1 0.7 1.8 12.4 4.61
    2×6 1 0.7 1.8 13.2 3.08
    2×10 7 0.7 1.8 15.4 1.83
    2×16 7 0.7 1.8 17.4 1.15
    2×25 7 0.9 1.8 20.6 0.727
    2×35 7 0.9 1.8 22.6 0.524
    2×50 10 1.0 1.8 26.2 0.387
    2×70 14 1.1 1.8 29.8 0.268
    2×95 19 1.1 1.9 34.0 0.193
    2×120 24 1.2 2.0 37.4 0.153
    2×150 30 1.4 2.2 41.2 0.124
    2×185 37 1.6 2.3 45.6 0.0991
    2×240 48 1.7 2.5 51.0 0.0754
    2×300 61 1.8 2.6 56.0 0.0601
    2×400 61 2.0 2.9 62.6 0.0470
    2×500 61 2.2 3.1 70.0 0.0366
    2×630 61 2.4 3.3 83.6 0.0283
    3×1.5 1 0.7 1.8 11.2 12.1
    3×2.5 1 0.7 1.8 12.1 7.41
    3×4 1 0.7 1.8 13.2 4.61
    3×6 1 0.7 1.8 14.0 3.08
    3×10 7 0.7 1.8 16.4 1.83
    3×16 7 0.7 1.8 18.6 1.15
    3×25 7 0.9 1.8 22.0 0.727
    3×35 7 0.9 1.8 24.2 0.524
    3×50 10 1.0 1.8 28.0 0.387
    3×70 14 1.1 1.9 32.1 0.268
    3×95 19 1.1 2.0 36.4 0.193
    3×120 24 1.2 2.1 40.3 0.153
    3×150 30 1.4 2.3 44.3 0.124
    3×185 37 1.6 2.4 49.1 0.0991
    3×240 48 1.7 2.6 54.9 0.0754
    3×300 61 1.8 2.7 60.1 0.0601
    3×400 61 2.0 3.0 67.4 0.0470
    3×500 61 2.2 3.2 75.3 0.0366
    3×630 61 2.4 3.5 90.0 0.0283

    3. 4 Core&5 Core

    Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
    4×1.5 1 0.7 1.8 12.2 12.1
    4×2.5 1 0.7 1.8 13.1 7.41
    4×4 1 0.7 1.8 14.3 4.61
    4×6 1 0.7 1.8 15.3 3.08
    4×10 7 0.7 1.8 18.0 1.83
    4×16 7 0.7 1.8 20.4 1.15
    4×25 7 0.9 1.8 24.3 0.727
    4×35 7 0.9 1.8 26.7 0.524
    4×50 10 1.0 1.8 30.8 0.387
    4×70 14 1.1 2.0 35.4 0.268
    4×95 19 1.1 2.1 40.4 0.193
    4×120 24 1.2 2.3 44.9 0.153
    4×150 30 1.4 2.4 49.3 0.124
    4×185 37 1.6 2.6 54.7 0.0991
    4×240 48 1.7 2.8 61.0 0.0754
    4×300 61 1.8 3.0 67.2 0.0601
    4×400 61 2.0 3.3 75.3 0.0470
    4×500 61 2.2 3.5 84.0 0.0366
    4×630 61 2.4 3.8 100.5 0.0283
    5×1.5 1 0.7 1.8 13.2 12.1
    5×2.5 1 0.7 1.8 14.2 7.41
    5×4 1 0.7 1.8 15.6 4.61
    5×6 1 0.7 1.8 16.7 3.08
    5×10 7 0.7 1.8 19.6 1.83
    5×16 7 0.7 1.8 22.3 1.15
    5×25 7 0.9 1.8 26.7 0.727
    5×35 7 0.9 1.8 29.4 0.524
    5×50 10 1.0 1.9 34.1 0.387
    5×70 14 1.1 2.1 39.1 0.268
    5×95 19 1.1 2.2 44.7 0.193
    5×120 24 1.2 2.4 49.7 0.153
    5×150 30 1.4 2.6 54.7 0.124
    5×185 37 1.6 2.8 60.6 0.0991
    5×240 48 1.7 3.0 67.7 0.0754
    5×300 61 1.8 3.2 74.6 0.0601
    5×400 61 2.0 3.5 83.4 0.0470
    5×500 61 2.2 3.8 93.4 0.0366
    5×630 61 2.4 4.1 111.7 0.0283

    4. 3+1 Core & 3+2 Core

    Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
    3×2.5+1×1.5 1 0.7 1.8 12.9 7.41
    3×4+1×2.5 1 0.7 1.8 14.0 4.61
    3×6+1×4 1 0.7 1.8 15.1 3.08
    3×10+1×6 7 0.7 1.8 17.3 1.83
    3×16+1×10 7 0.7 1.8 19.8 1.15
    3×25+1×16 7 0.9 1.8 23.3 0.727
    3×35+1×16 7 0.9 1.8 25.1 0.524
    3×50+1×25 10 1.0 1.8 29.4 0.387
    3×70+1×35 14 1.1 1.9 33.5 0.268
    3×95+1×50 19 1.1 2.1 38.1 0.193
    3×120+1×70 24 1.2 2.2 42.5 0.153
    3×150+1×70 30 1.4 2.3 45.8 0.124
    3×185+1×95 37 1.6 2.5 51.2 0.0991
    3×240+1×120 48 1.7 2.6 57.0 0.0754
    3×300+1×150 61 1.8 2.8 62.6 0.0601
    3×400+1×185 61 2.0 3.1 70.1 0.0470
    3×500+1×240 61 2.2 3.3 78.3 0.0366
    3×630+1×300 61 2.4 3.6 92.1 0.0283
    3×2.5+2×1.5 1 0.7 1.8 13.8 7.41
    3×4+2×2.5 1 0.7 1.8 15.1 4.61
    3×6+2×4 1 0.7 1.8 16.2 3.08
    3×10+2×6 7 0.7 1.8 18.5 1.83
    3×16+2×10 7 0.7 1.8 21.3 1.15
    3×25+2×16 7 0.9 1.8 24.9 0.727
    3×35+2×16 7 0.9 1.8 26.6 0.524
    3×50+2×25 10 1.0 1.8 31.4 0.387
    3×70+2×35 14 1.1 2.0 35.6 0.268
    3×95+2×50 19 1.1 2.1 40.4 0.193
    3×120+2×70 24 1.2 2.3 45.5 0.153
    3×150+2×70 30 1.4 2.4 48.5 0.124
    3×185+2×95 37 1.6 2.5 54.2 0.0991
    3×240+2×120 48 1.7 2.7 60.3 0.0754
    3×300+2×150 61 1.8 2.9 66.5 0.0601
    3×400+2×185 61 2.0 3.2 74.3 0.0470
    3×500+2×240 61 2.2 3.5 83.1 0.0366
    3×630+2×300 61 2.4 3.8 97.0 0.0283

    Ordering Options:
    For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data :

    1 International or Special Standard. (Alternatively, the precise usage of the cable.)
    2 Rated voltage.
    3 Copper or Aluminium conductors.
    4 Size of each conductor.
    5 Insulation material : PVC XLPE or others.
    6 Number and identification of conductors.
    7 Other requirements.
    8 Packing.
    9 Required delivery time.
    10 Required validity.

    If this all seems a litle too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

    Company information:

    30 years of experience in R & D, production and sales of wire and cable.

    Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

    Annual revenue is about 500 million US dollars.

    CNAS laboratory, more than 100 testing reports.

    Products are widely used in real estate, municipal, industrial support, mobile communications etc

    Quality Cu Conductor Power cable LZSH Halogen Free Flame Retardant Cables DJX cable WDZ-YJY Cable N2X2Y 4 Core for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Low Smoke Halogen Free Cable products from this supplier
    Inquiry Cart 0