    5ppm Infrared SF6 Air Purity Sensor 0-90%RH

    KSS532 Infrared SF6 Purity Sensor


    1. Overview

    KSS532 is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of SF6 gas at 10.6um. KSS532 adopts MEMS light source, optical cavity with special structure and dual-channel detector to realize space dual optical path reference compensation, and microprocessor for signal acquisition, processing and output. KSS532 has good selectivity, high sensitivity, no oxygen dependence, long life, low power consumption; Built-in temperature sensor for temperature compensation; At the same time, it has UART and 485 output, which is convenient for customers to apply various applications.


    2. Technical parameters


    parametersymbolminimumTypical valuesmaximumunit
    Storage TemperatureTstg-20-80°C
    Operating TemperatureTA-2060°C
    Operating HumidityHA090% RH
    Work PressurePA0.81.2atm
    Supply VoltageVs111230V
    Maximum Operating CurrentIavg100120150mA
    Detection Range (customizable).Ra1500ppm
    ResolutionResolution5ppm
    Measurement AccuracyAcurracy± 30 or ±5% true value is the greater%vol
    T90 Pipeline TypePump suction5second
    Diffusion30second
    RepeatabilityZeroLess than ±50ppm
    RangeLess than ±5%.
    Life Span510year

    3. Structural Dimension Drawing

    Unit: mm


    KSS532 block diagram (diffusion and pumping compatible).


    Pump suction type: length * width * height: 61mm * 40mm * 32mm

    Diffusion type: length * width * height: 61mm * 40mm * 18mm


    4. Installation instructions

    The sensor mounting positioning hole is installed according to the structural dimension drawing, and the aperture is 3.2mm.

    The wiring socket spacing is 2.54 m m.


    5. Matters that should be paid attention to in maintenance

    The sensor should be calibrated regularly, not more than 3 months is recommended.

    Do not use the sensor for a long time in an environment with a high density of dust.

    Please use the sensor within the range of the sensor's power supply.


    6. Ordering Instructions

    In order to be able to purchase the specific specifications required, please provide the following information

    1) Sensor name

    2) Measure the gas

    3) Sensor range

    For example, SW320D, SF6, 0-5000 ppm


    7. Order Information


    Order information sheet
    KSS532KSS532 CO2 concentration sensor
    xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
    2000Range 200ppm (default).
    10000Range 10000ppm
    50000Range 50000ppm
    encodeThe reaction speed is divided into two types: fast and slow
    SSlow (default).
    Qfast
    encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
    CustomConfirm the baud rate before ordering
    24002400bps baud rate
    96009600bps baud rate
    1920019200bps baud rate
    3840038400bps baud rate (default)
    encodeSerial port protocol
    Modbus-RTUStandard Modbus-RTU protocol (default).
    Modbus-ASCIIStandard Modbus-ASCII protocol
    Modbus-SelfModbus private protocol
    KSS532-2000-S-38400-Modbus-RTU

    8. Contact Details

    URL: www.kacise.com

    Tel: +86-29-17719566736

    Email: sales@kacise.com

    Address: Tangyan South Road, Xi'an City, Shaanxi Province, China


    Appendix


    ShorthandFull name
    VOL1% VOL refers to 1% of the volume of a particular gas in air.
    PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
    O2Oxygen molecules
    LCDLCD display
    RS485Asynchronous serial port 485
    DCdirect current
    ACCommunication
    PVCpolyvinyl chloride

    Quality 5ppm Infrared SF6 Air Purity Sensor 0-90%RH for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Gas Detector Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0