Sign In | Join Free | My burrillandco.com
Home > Auto Electrical System >

GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

    Buy cheap GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS from wholesalers
     
    Buy cheap GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS from wholesalers
    • Buy cheap GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS from wholesalers
    • Buy cheap GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS from wholesalers

    GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

    Ask Lasest Price
    Brand Name : GCE
    Model Number : 2U
    Certification : CE
    Price : negotiate with:wenglin@hngce.com, WhatsAPP me: +86-15570747076
    Payment Terms : T/T, L/C
    Supply Ability : 2000 Sets per Month
    Delivery Time : 20 work days
    • Product Details
    • Company Profile

    GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

    GCE RS485 CAN Protocol ESS BMS 204.8V50A 64S High Voltage 2U BMS


    Product Features:


    ※ Advanced battery management system---The highly integrated battery management system can realize seamless monitoring.

    ※ Perfect self-checking and running status checking function, with HMI display screen, system running information is clear at a glance.

    ※ Complete and reliable system control and protection strategies, comprehensively guarantee battery safety and escort to extend the life of battery packs.

    ※ Modular design, configurable and expandable---multiple energy storage units can be flexibly combined and expanded into a larger energy storage system.

    ※ Abundant communication interfaces---multiple RS485, CAN, Ethernet, dry contact input and output interfaces, supporting communication with most PCS and monitoring servers on the market.

    ※ The communication interface protocol is flexible---the factory comes with the company's communication protocol, and it can also be adapted to the PCS of different manufacturers according to customer needs.

    ※ The built-in large-capacity memory chip can store a large amount of key operating data, and an SD card can be added to realize battery historical data storage

    ※ Automatic circulation control and automatic parallel/offline control can easily realize the parallel connection of battery packs.



    Application:


    ◎ Photovoltaic power station energy storage

    ◎ Island off-grid energy storage

    ◎ ESS

    ◎ Micro-grid

    ◎ UPS power supply

    ◎ Power System 220V DC power supply



    Product Specifications:

    Basic Parameters

    Max. current50A

    Max. voltage

    350V, 500V(according to the rated voltage)

    Power consumption

    ≤15W

    Current sampling accuracy

    1%FSR

    Insulation withstand voltage

    2800VDC <1mA 1min

    Protection level

    IP20

    Size(W*H*D)

    482*89*500(mm)

    New Weight

    ~10Kg

    Communication Interface

    Communication port with BMU

    CAN

    Communication port with UPS

    RS485/CAN

    Communication port with SBMS

    RS485/CAN

    Communication with monitoring software

    Ethernet

    Basic Function

    Battery charge & discharge management

    Available

    Battery temperature management

    Available

    IAP Upgrade

    Available

    System protection parameter setting

    Available

    Short circuit protection

    Available(6KA 20ms)

    Pre-charge function

    Available

    Parallel circulation control

    Available

    Event record

    Available(5000)

    DC start

    Available(Battery powered, Mains supply is only for the signal to start on and off the BMS)

    Optional function

    Insulation detection

    No

    HMI display

    3.5 inches(Embedded in the chassis)

    Stand-alone or parallel function

    Set up before leaving the factory

    Dry contact

    Maximum 2 dry contact outputs

    Others

    Color

    RAL9005 black sand grain

    Installation method

    Suitable for standard 19-inch rack installation

    Incoming and outgoing wire method

    Front side in and front side out.

    Operating ambient temperature

    -20℃~60℃

    Operating ambient humidity

    5%~75%RH

    Comply with National standards

    GB/T 16935.1 GB/T 17626.2 GB/T 17626.5

    Certification

    Comply with CE certification standards


    RBMS Accessories List:


    Name

    Specifications

    QTY

    Image

    Power Terminal

    GPS50AFP Blue

    1

    Power Termina

    GPS50AFP Red

    1

    Power terminal connector

    S1339G2

    4

    AC socket(writeable)

    250V 10A

    1

    Dry contact terminal

    5.08-6Pin

    1

    Terminating resistor

    120R

    1

    Precautions For Use:


    1)There is a high voltage inside the energy storage system. It is strictly forbidden to open the case for disassembly,

    assembly and maintenance without the company or its authorized technicians, otherwise the electric shock will be released and the warranty rights will be lost.

    2)It is strictly prohibited for any wire or connector in the BMS to overlap the positive and negative poles of the battery,

    otherwise there may be a danger of short circuits and damage to the circuit board.

    3)it is strictly prohibited to be close to the water source or fire source to avoid the fire of the battery due to a short circuit or overheating.

    4)after the secondary protection is triggered, the circuit breaker is controlled by BMS. After disconnection, the system must be powered off to eliminate the fault,

    and can be powered on and started again after an interval of at least 1 minute, otherwise, it may cause damage to the shunt coil of the circuit breaker because it is too late to emit heat.

    5)If you need to cold start the UPS/PCS from the battery, you must first close the battery switch on the UPS/PCS side before starting the battery.

    If you start the battery first, and then close the battery switch on the UPS/PCS side, since the DC side of the UPS/PCS side generally has a large capacitance,

    the instantaneous capacitance is equivalent to a short circuit. At this time, the current charged by the battery to the capacitor will be much higher than that of the RBMS machine.

    The rated value of the contactor is very easy to cause ablation and adhesion of the contactor's contact.

    The contact resistance of the contactor's contact increases and heats up or the contact cannot be disconnected, which triggers the secondary protection


    Safety Precautions:


    1)The tools used by installation and commissioning personnel must have insulation protection.

    2)During installation, debugging and maintenance, you must wear insulated rubber gloves, goggles, and insulated rubber boots as appropriate to avoid safety accidents as much as possible.

    3)If the metal of the wire ends during the installation, debugging and maintenance process falls into the battery room, be sure to use an insulated tool to take it out, and do not leave the sundries.

    4)When maintenance is required, the main circuit breaker of the RBMS must be disconnected, and the connection between the battery pack and the PCS DC bus must be cut off.

    5)According to different project requirements, the parameters such as the charge and discharge current and charge and discharge voltage of the battery management system have been set during the initial installation and commissioning.

    The parameters must not be changed without authorization, otherwise, the battery life may be shortened, and the battery may be affected more seriously. Cause serious harm and cause safety accidents.

    6)In case of fire around the energy storage cabinet, please use a dry powder fire extinguisher or fire sand to extinguish the fire. Using liquid to extinguish the fire may cause electric shock.

    7)If the system is not used for a long time, be sure to disconnect the main circuit breaker of the battery cabinet.

    8)Try to avoid long-term use in the following working environment:

    ◎Places that exceed the temperature or humidity range specified in the specification

    ◎Places subject to strong vibration or susceptible to impact

    ◎Places exposed to direct sunlight or close to heat sources

    ◎Places with dust, strong corrosive substances, flammable and explosive materials, and high salt spray


    Quality GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Hunan GCE Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Energy Storage BMS products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0