Sign In | Join Free | My burrillandco.com
Home > Water Treatment >

Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

    Buy cheap Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test from wholesalers
     
    Buy cheap Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test from wholesalers
    • Buy cheap Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test from wholesalers

    Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-100
    Certification : IFCC, NGSP, CE
    Price : Negotiation
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 100/Day
    Delivery Time : 15-20 working days
    • Product Details
    • Company Profile

    Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

    Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test


    The Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin TestI is a automated desktop point-of-care analyzer for measuring glycated hemoglobin (HbA1c) to diabetes diagosis.


    The Test Cartridge is individually packaged containing the reagents necessary for the determination of hemoglobin A1c one test.



    Specification


    ModelLD-100
    MethodBoronate Affinity
    Measurement Time≤2 minutes
    Sample TypeWhole blood
    Measurement Range4.0-15%
    Sample Volume4μL
    Shelf life of test kit9 months
    Weight≤800g
    Dimensions192(L)*128(W)*108(H)mm


    Principle


    The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent substance.


    The Application of Boronate affinity in Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test.


    After the magnetic beads are pushed into the kit, the borate in the reagent binds to the fluorophore in the magnetic beads, resulting in a large amount of excited fluorescence

    After the magnetic beads are pushed into the kit, the borate binds to the fluorophore, producing a large amount of excited fluorescence.

    After the sample is added to the reagent, the borate-fluorophore competes with hemoglobin for binding, resulting in a decrease in fluorescence. Because the binding force of unglycated hemoglobin is much greater than that of glycated hemoglobin, the unglycated hemoglobin first binds to the borate-fluorophore, resulting in a sharp drop in fluorescence. The content of unglycated components can be detected during this process.

    Next, the glycosylated hemoglobin is bound to a borate-fluorophore. This binding process is slow and therefore the fluorescence quenching process is slow and curvilinear. The fluorescence quenching process in the detection cycle of the instrument can reflect the content of glycosylated hemoglobin.



    Feature


    Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

    Ease of use: One-step operation the instrument is ready for use.

    • Less than 3-minute test time

    • A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

    • With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

    • Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).




    Performance Parameters

    • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
    • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
    • Linearity:In the range of 4%-15% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
    • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
    • Functions of the analyzer:The function of report output in English; Abnormal alarm function.

    Certificate


    Quality Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more POCT HbA1c Analyzer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0