Sign In | Join Free | My burrillandco.com
Home > Other Security & Protection Products >

Self Protected Design Surge Protection For Cctv Systems BNC Interface Imax 20KA

    Buy cheap Self Protected Design Surge Protection For Cctv Systems BNC Interface Imax 20KA from wholesalers
     
    Buy cheap Self Protected Design Surge Protection For Cctv Systems BNC Interface Imax 20KA from wholesalers
    • Buy cheap Self Protected Design Surge Protection For Cctv Systems BNC Interface Imax 20KA from wholesalers

    Self Protected Design Surge Protection For Cctv Systems BNC Interface Imax 20KA

    Ask Lasest Price
    Brand Name : Uchi
    Model Number : OBVT-BNC
    Certification : CE / SGS / ISO9001
    Price : Negotiate
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 60000 pieces per month
    Delivery Time : 5-15 days after payment
    • Product Details
    • Company Profile

    Self Protected Design Surge Protection For Cctv Systems BNC Interface Imax 20KA

    5VDC BNC Surge Arrester / CCTV Surge Protection Device with10kA 20KA


    OBVT-BNC

    Coaxial BNC Video Surge Protectors are designed to guard computer network system that includes the monitoring system of security system, coaxial signal transmission and close -circuit TV, satellite communication system.

    OBVT is the series of devices for discharging transient overvoltages induced in coaxial lines. In accordance with IEC 61643-21. Coaxial format.

    Suitable for the protection of radiofrequency transmission and reception equipment. By their nature, they are highly exposed to induced transient overvoltages (surges) associated with meteorological activity.
    For BNC, F, N, TNC connectors.
    Ideal for the protection of transmission and reception systems such as TV and radio antennas, closed circuit TV (CCTV), alarms, etc.


    Technical Parameters


    OBVT-BNCOBVT-NOBVT-F
    Nominal Operating Voltage (Un)DC5V
    Maximum Continuous Operating Voltage (Uc)DC8V
    Nominal Discharge Current In (8/20µs)kA10kA
    Maximum discharge current Imax (8/20µs)kA20kA
    Voltage protection level (Up)<120V
    InterfaceBNCNF
    Bandwidth (MHz)10-40
    Response time tA<10ns

    Feature&Benefits

    -Easy installation
    -Fail-safe /self-protected designVery fast response
    -Hybrid GDT and Diode TechnologyLong distance transmission
    -Good transmission effectStrong anti-interference
    -complies lEC 61643-21 standard


    Note: The system lightning protection does not guarantee that the equipment will not be 100% damaged by lightning; the power system must be multi-level lightning protection;
    The complete lightning protection system includes external lightning protection and internal lightning protection. External lightning protection refers to: lightning receptors, down conductors, and grounding bodies, which are mainly used to defend against direct lightning strikes. Internal lightning protection includes: shielding, reasonable wiring, safe distance, equipotential connection, overvoltage protection, etc., mainly used to prevent lightning induction, ground potential counterattack, lightning wave intrusion, etc.


    Application


    ●AC/DC distribution
    ●Power supplies
    ●Industrial automation
    ●Telecommunications
    ●Motor controls systems
    ●PLC applications
    ●Power transfer equipment
    ●HVAC applications
    ● AC drives
    ●UPS systems
    ●Security systems
    ●IT/Data centers

    Tip: Lightning protection is probabilistic protection, and we cannot provide 100% protection.


    First, lightning discharge itself has a certain degree of randomness, and lightning parameters have certain statistical properties, which determines that all protective measures based on these statistical characteristics of lightning parameters cannot provide 100% protection. Such as: direct lightning protection-shielding characteristics; lightning current amplitude, waveform, etc. have statistical properties;
    Second, the lightning protection equipment cannot prevent the formation of lightning flashes;
    Third, lightning protection devices cannot ideally eliminate all interference voltages/currents. The fundamental purpose of taking protective measures is to ensure that most of the energy caused by interference does not spread to the vulnerable parts of the device and the staff.
    Finally, the cost of protection against high-level surges with a small probability of occurrence has risen sharply.


    Others


    Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

    Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

    Max Discharge Current
    Imax(KA)

    Protection Level(KA~)Response Time(ns)
    DGM1(2)-D5220/380

    275/320
    385/420

    5101.2≤25
    DGM1(2)-D101021.6
    DGM1(2)-C2020401.8
    DGM13-B303060.2.2
    DGM3(4)-B4010802.4
    DGM(4)-B60601002.8
    DGM-N-PE220/25540/6060/801.2≤100


    Importance of theground connection
    Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
    A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.

    What skills should lightning protectors have in the selection?
    1.Confirm power supply system
    First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
    For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
    2.Know the main parameters of the lightning arrester.
    FAQ


    Q: Can I get some samples?
    A: Yes, Sample orders welcomed.

    Q: Can I use my own Logo or design on goods?
    A: Yes, Customized logo and design on mass production are available.

    Q:What is the delivery time?
    A: 3 days for samples, 7-15 days for mass production.

    Q: What is the payment term?
    A: T/T, L/C at sight, West union , Paypal, etc.

    Quality Self Protected Design Surge Protection For Cctv Systems BNC Interface Imax 20KA for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Guangdong Uchi Electronics Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Surge Protection Device SPD products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0