    Ask Lasest Price
    Brand Name : Forsentek
    Model Number : FFA
    Certification : CE
    Payment Terms : T/T,Western Union or Paypal
    Supply Ability : 2690pcs/month
    Delivery Time : 3~25 working days
    • Product Details
    • Company Profile

    Press Load Cell 20kg 50kg 100kg 200kg 500kg 1ton 2ton Push Force Load Cell

    Press Load Cell 20kg 50kg 100kg 200kg 500kg 1ton 2ton Push Force Load Cell

    Flange to Flange Press Load Cell FFA is made of stainless steel utilizing strain gauge technology to deliver maximum 0.1% non-linearity of full scale.Pull And Push Force Sensor FFA offers 20kg / 50kg / 100kg / 200kg / 500kg / 1000kg / 2000kg seven rated load capacities to choose from, pull push force transducer FFA can be used for both tension and compression force measurement. Stainless steel construction, flange design, compact size, bidirectional force measurement, high accuracy, Push Force Load Cell FFA offers a perfect force measuring solution for applications such as wire tension control, force distribution analysis, automated control, cylinder thrust force measurement, assembly force monitoring, spring testing, ultrasonic welding clamp force control, hand press force verification, and so on. In addition to the standard specifications, Forsentek is also capable of and willing to provide custom design service to meet requirements of different applications.

    50kg_Press_Load_Cell_100kg

    Dimensions(Unit in "mm")

    2000kg_Press_Load_Cell_1000kg

    Ordering codeMeasurement RangeForce direction
    FFA-200N0-200N / 0-20kgfTension/compression
    FFA-500N0-500N / 0-50kgf
    FFA-1kN0-1000N / 0-100kgf
    FFA-2kN0-2000N / 0-200kgf
    FFA-5kN0-5000N / 0-500kgf
    FFA-10kN0-10kN / 0-1000kgf
    FFA-20kN0-20kN / 0-2000kgf

    Specifications

    Capacity

    200N / 20kg / 45 lb
    500N / 50kg / 110lb
    1000N / 100kg / 220lb

    2000N / 200kg / 450lb
    5000N / 500kg / 1.12klb
    10kN / 1000kg / 2.25klb

    20kN / 2000kg / 4.5klb

    Rated output2.0 mV/V
    Excitation3-15V
    Zero balance±0.05mV/V
    Nonlinearity±0.1% of capacity
    Hysteresis±0.1% of capacity
    Nonrepeatability±0.05% of capacity
    Creep(5min)±0.05% of capacity
    Safe overload150% of capacity
    Ultimate overload200% of capacity
    Compensated temperature-10...+40oC
    Operating temperature-20...+60oC
    Temperature shift zero±0.02% R.O./oC
    Temperature shift span±0.02% R.O./oC
    Input resistance385±30 ohms
    Output resistance350±10 ohms
    Insulation resistance>2000M ohms
    Ingress protectionIP62
    Material of elementStainless steel
    CableØ3*3000mm 4-core shielded
    Wiring code

    Red--Excitation+ Black--Excitation-

    Green--Signal+ White--Signal-


    Instruction of load cell output:
    Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a sensor.
    Sensor output = (Power supply * Rated output) * Load / Capacity
    Rated output of pull push load cell FFA is around 2.0mV/V.
    Power supply of flange type press force sensor FFA is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the output range of push force transducer FFA is normally within -30mV...+30mV for tension and compression force measurement.
    Example: Flange Mounted Push Load Cell FFA-5kN with 2.0mV/V sensitivity powered by 10V DC,the output range is -20mV...+20mV.

    A load cell amplifier can be used to convert mV signal into -5-5V , 0-10V, 4-20mA.

    Example: Press Load Cell FFA-10kN working with 0-10V amplifier,the Force-Voltage relationship will be 0-10kN compression load corresponds to 0-10V voltage output,which is linear regardless of the measurement error.

    Press Load Cell 20kg 50kg 100kg 200kg 500kg 1ton 2ton Push Force Load Cell

    200kg_Press_Load_Cell_500kg
    Click here to download datasheet

    Quality Press Load Cell 20kg 50kg 100kg 200kg 500kg 1ton 2ton Push Force Load Cell for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Forsentek Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Flange load cell products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0