Sign In | Join Free | My burrillandco.com
Home >

Dial Code On The Back 12VDC Motion Sensor Automatic Control Liner Design Easy To Install

    Buy cheap Dial Code On The Back 12VDC Motion Sensor Automatic Control Liner Design Easy To Install from wholesalers
     
    Buy cheap Dial Code On The Back 12VDC Motion Sensor Automatic Control Liner Design Easy To Install from wholesalers
    • Buy cheap Dial Code On The Back 12VDC Motion Sensor Automatic Control Liner Design Easy To Install from wholesalers

    Dial Code On The Back 12VDC Motion Sensor Automatic Control Liner Design Easy To Install

    Ask Lasest Price
    Brand Name : HAISEN
    Model Number : HD016VCR 2
    Certification : CE RoHS
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 200,000pcs per month
    Delivery Time : 1-3 days for sample order, 1-2 weeks for bulk order
    • Product Details
    • Company Profile

    Dial Code On The Back 12VDC Motion Sensor Automatic Control Liner Design Easy To Install

    Dial Code On The Back 12VDC Automatic Control Liner Design Easy To Install


    Dial code setting of motion sensor:

    1.Support 9-bit dialing code combibation to set parameters to achieve the desired scenario.

    2.code 1,set the detection area;

    code 2&3,set the hold time;

    code 4&5,set the daylight threshold;

    code 6&7,set the stand-by period;

    code 8&9,set the stand-by dimming level.


    Detection area
    In this area, movement will be detected and able to trigger the sensor. 100% detection area is also known as the strong sensitvity.
    Hold-time
    The period of light keeping 100% brightness after moving objects leave the
    detection area.
    Daylight threshold
    Definition of the ambient brightness; only when the ambient brightness is lower than the preset specific lux amount, the sensor will work; when it's preset as "disable", the sensor works everytime it detects motion regardless the ambient
    brightness.
    Stand-by period
    The period of light keeping low output before it's completely switched off. When it's preset as"∞“, the light always keep at low output if no movement in the detection area and doesn't turn off.
    Stand-by
    dimming level
    The definition of low output in the standby period.


    Wiring diagram of DC sensor:
    Wire color+12V(Red),GND(Black),OUT(Yellow)
    Control methodON/OFF/ DIM /1-10V / remote control
    Microwave frequency5.8GHz±75MHz
    Microwave power<0.3mW
    Operating voltage12VDC±5%
    Power<0.5w
    1.The wire color would be Red +12VDC,Black GND,Yellow OUT

    2.The output is 0-10V dimming

    Detection area of DC sensor:
    This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.
    Typical installation height 2.5-4m
    Mounting height≤4M/13.12FT(ceiling mounted)
    Detection rangeMax,ø14m/45.92ft (ceiling mounted)
    Detection angle30°-150° (without glass)
    Motion detection0.5~1.5m/s

    Dimmensions of DC Sensor:

    SizeL*W*H:85*22.3*24.5MM
    Wire length525mm(without the crystal joint)
    Operating temperature-20°C~+60°C
    Warranty5 years
    Function settingBy remote control and dial code
    IP gradeIP 20

    1.White four-core wire,excluding terminal length 525mm.


    Mechanical structure of DC sensor:

    Connect methodWire line 525mm,+12V(Red),GND(Black),OUT(Yellow)
    ConnectorLead the output
    Stand-by period0s/30s/20min/+∞
    Stand-by dimming level10%/20%/30%/50%
    Detection area100%/50%
    Hold time5s/30s/1min/10min
    Daylight thresholdDisable/50Lux/10Lux/2Lux

    1.Connector:4 PIN wire crystal head
    2.Installation hole:Two mounting holes for easy fixation in the lamps
    3.Daylight sensor:Strain the light intensity, convert the light signal into electrical signal, control the switch of the lamp
    4.Antenna module:Detect motion signals of objects.


    Application:
    1. Automatically ON/OFF function:
    With sufficient daylight,even when motion detected,light remains OFF.
    With insufficient daylight,when motion detected, light ON.
    After the last detection and the present hold time elapsed, light OFF.
    2. No daylight function
    When the daylight threshold is set to "Disable".
    Light on when detect movement, After people leave, Light off after stand-by period.
    Applications: Dim places such as Basement Parking, Underpass.
    When motion is detected, the sensor will switch on the light to 100% brighteness.
    After people leave the detection area, light remains 100% brightness within hold time.
    After the last detection and the present hold time elapsed, light OFF.

    3. Function Demo - Dimmable control/Corridor function
    With sufficient daylight,even when motion detected,light remains OFF.
    With insufficient daylight,when motion detected, light ON.
    After last detection, the light will be dimmed down to the stand-by
    dimming level (10%,20%,30% or 50%) after holdtime.
    After the stand-by period, light OFF.

    Installation Method of DC Sensor:

    Installation precautions of motion sensor1. Microwave sensor can be installed in any lamp except the one with full metal shell.
    2. The detected surface cannot be shielded by metal objects.
    3. Make sure the microwave module is completely exposed outside.
    4. The detection surface of the sensor module shall be installed facing the detection area.
    5. Should be kept away from the driver to avoid interference generation and lamp flashing.
    6. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.

    Features of ON/OFF Sensor:

    1. Rod Antenna Module to avoid any shadow

    2. DIP switch rightabout the rod antenna, to make it easier to set all parameters needed

    3. Super slim design to be suitable for linear light, tri-proof light, panel light, ceiling light

    4. 0-10V output to support dimming function and save energy

    5. More options of dimming level to provide better experience for end users

    6. With plug in the end of the wire to make it easier to be connested with the LED driver

    7. RED(12VDC input) / BLACK(GND) / YELLOW(0-10V OUTPUT)


    HD016VCR 1, 2.pdf



    Quality Dial Code On The Back 12VDC Motion Sensor Automatic Control Liner Design Easy To Install for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen HAISEN Technology Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more DC Motion Sensor products from this supplier
    Inquiry Cart 0