Sign In | Join Free | My burrillandco.com
Home > Herbal Medicines >

P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board

    Buy cheap P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board from wholesalers
     
    Buy cheap P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board from wholesalers
    • Buy cheap P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board from wholesalers
    • Buy cheap P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board from wholesalers
    • Buy cheap P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board from wholesalers
    • Buy cheap P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board from wholesalers

    P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board

    Ask Lasest Price
    Brand Name : PHiliph
    Model Number : M4735-40016
    Payment Terms : T/T(wire transfer), Western Union, Paypal
    Delivery Time : 3-5 working days
    MOQ : One piece
    • Product Details
    • Company Profile

    P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board


    PHiliphh M4735A XL defibrillator power supply board M4735-40016


    PCA control

    The PCA controller performs the following functions:

    System-wide processing.

    System-wide clock and control functions including:

    A. Check the power on/off sequence.

    B. Save the configuration options created by the user.

    C. Storage of operating software, including data used to create graPHiliphhilipics and display formats.


    Important network pages among other features of the PCA.z user interface, including:

    A.Generates and controls sounds and audio signals.

    B. Generate and format real-time information for monitors and printers.

    C. Check printer functions.

    D. LED display control to set time, speed, AC power, battery charge.


    Control data flow to and from the data card.


    Power PCA defibrillation control features include:

    A. Start the capacitor charging sequence.

    B. Monitor the charge on the capacitor.

    C.Start the download sequence.

    ​​

    control features on Power PCA including:

    A. Start / stop stimulation.

    B. User-selected rate and output control and delivered pacing current control.

    Frontal ECG monitoring in parametric PCA (electrocardiogram) and power PCA (paddle/paddle electrocardiograPHiliphhilip).

    5V logic power supply regulation and generation


    Item namePHiliphh M4735A XL defibrillator power supply board M4735-40016
    BrandPHiliphh
    Model

    M4735-40016


    Use placeHospital Devices; Medical Care; ICU;
    Deliver time3-5 days
    Warranty90 days

    Power PCA

    Power PCA performs the following functions:

    1. Analogous front for ECG electrodes.

    2. Impedance measurement for the Blade Connection Indicator (PCI) function.

    3. Generation and control of pacing waveforms according to PCA control instructions.

    4. Monitoring of pacemaker function as prescribed by the PCA for monitoring:

    a)to charge the capacitor to the correct power level.

    b) Power supply and waveform control

    c) Discharge capacitor (discharge).


    Removal

    1. Disconnect the patient connector from the power supply PCA.

    A. Disconnect the 9-pin connector and press the latch to release.

    B. Tighten with the needle clamp to disconnect the two high pressure vane connectors.

    2. Disconnect the battery PCA from the power PCA.

    A. Disconnect the large white 4-pin connector and press the latch to release. This connector has four battery wires (two red, two black).

    B.Disconnect the small 2-pin connector; Press the latch to release.

    3. Disconnect the power supply.

    A. Disconnect the 6-pin connector from the Power PCA and press the latch to release. Note that it only contains three wires.

    B. Disconnect the 4-pin PCA connector from the power supply, press the latch to release.

    4. Disconnect the controller PCA ribbon cable. Disconnect the large ribbon cable from the control PCA. The other end should have been disconnected from the control PCA.

    5. Remove the power supply PCA.

    A. Remove the 6-T10 screws from the Power PCA.

    B. Lift the Power PCA and loop it around the patient interface and backrest.

    Tip: Lift the back edge of the PCA (near the power supply) first. Then drive the PCA to the right to release the patient connector and case and lift the PCA out of the case

    Parameter PCA

    The PCA parameter performs the following functions:

    1. Connect the ECG lead, ECG output cable, and SpO2 module.

    2. Analog ECG terminal for 3 and 5 lead ECGs.

    3. SpO2 on/off logic and patient isolation


    Power Supply

    The Power Supply provides regulated DC power to the unit and charges the Battery


    If you're interested in P/N M4735-40016 PHiliphh M4735A XL Defibrillator Power Supply Board,feel free to contact us .Thank you .


    Quality P/N M4735-40016 PHiliph M4735A XL Defibrillator Power Supply Board for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Defibrillator Machine Parts products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0