Sign In | Join Free | My burrillandco.com
Home > Measuring & Analysing Instrument Design Services >

PH Probe With 0~100℃ Working Temp. For Surface Water

    Buy cheap PH Probe With 0~100℃ Working Temp. For Surface Water from wholesalers
     
    Buy cheap PH Probe With 0~100℃ Working Temp. For Surface Water from wholesalers
    • Buy cheap PH Probe With 0~100℃ Working Temp. For Surface Water from wholesalers
    • Buy cheap PH Probe With 0~100℃ Working Temp. For Surface Water from wholesalers

    PH Probe With 0~100℃ Working Temp. For Surface Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : ASP101-VYD01
    Certification : CE, ISO
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5- 20 work days
    Price : Negotiable
    • Product Details
    • Company Profile

    PH Probe With 0~100℃ Working Temp. For Surface Water


    pH probe with 0~100℃ working temp. for surface water


    Our factory uses a special glass probe that is sensitive to pH on the measuring electrode. It is made of special glass that can conduct electricity and penetrate hydrogen ions. It has the characteristics of high measurement accuracy and good anti-interference. When the glass probe comes into contact with hydrogen ions, a potential is created. Potentials were measured against a reference electrode with a silver wire suspended in a silver chloride solution. The pH value is different, and the corresponding potential is also different.


    It is converted into a standard 4~20mA output by the transmitter.


    Specification:

    Product Name

    pH sensor

    Product Model

    ASP101V-VYD01

    pH Range

    0~14pH

    Resolution

    0.01pH

    Shaft Material

    Glass

    Working TEMP

    0~100℃

    Reference System

    double salt bridge

    Reference Electrode

    Ag/AgCl

    Electrolyte

    Crystal

    Working Pressure

    0~4Bar

    Temperature Unit

    ——

    Membrane

    Ceramic hole

    Glass Head

    Blue low impedance

    Dimension

    Diameter: 12mm Length:120mm

    Thread Size

    ——

    Lead Wire

    Standard 3m

    Ground

    ——

    Cleaning

    ——

    Application

    Dirty water


    Please click the catalog of pH controller here:

    Daruifuno Catalog.pdf


    Brief introduction:

    • Glass shell pH composite electrode;

    • Blue low impedance hemispherical glass head, high strength, not easy to break;

    • The reference is ceramic hole shape core, it has the characteristics of smooth response, no potential drift and good stability;

    • The reference system is Ag/AgCl, double salt bridgefilled with KCl colorless high temperature gel;

    • The reference electrolyte is saturated KCL+ excess KCL crystal, the service life is long;

    • The ASP101 pH electrode can not only be used for drinking water but also in wastewater, sewage and other industria applications.

    Aplication: Pure water monitoring

    Drinking water,surface water,water quality analyze,ground water,ect.


    Industrial process monitoring and dosing control

    Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


    FAQ

    1. What is themeasurement principle of this pH electrode?
    A:
    The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


    2. How is this glass pH electrode composed?
    A:
    The pH electrode is usually composed of an indicator electrode and a reference electrode.


    3. How to judge the pH of the solution?
    A: If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7


    4. What is the wire length of the pH electrode?
    A: The lead wire of this electrode is 3m by default, other lengths need to be customized.


    5. How often must the pH sensor be calibrated?
    A: Depends on the type of sample:
    Dirty samples and non-aqueous samples require more frequent calibration.
    Depends on the required accuracy:
    For very accurate measurements, at least daily calibration is required.
    Depends on the quality of the electrode:
    Old electrodes require more frequent calibration.

    Quality PH Probe With 0~100℃ Working Temp. For Surface Water for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more pH ORP Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0