    Flow Through Installation SUS316 Solution Ground PH Electrode For Pure Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : ASP500-NYD05
    Certification : CE
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-20 days
    • Product Details
    • Company Profile

    Flow Through Installation SUS316 Solution Ground PH Electrode For Pure Water


    Flow-Through Installation SUS316 Solution Ground PH Electrode For Pure Water


    Hydrofluoric acid above a certain concentration (>1g/L) and below pH 5 will corrode the standard electrode glass membrane and prevent the formation of a gel layer. This results in unstable measurements and greatly reduces electrode life. For high hydrofluoric acid concentration measurements, antimony electrodes are recommended for measurement.


    Electrodes need to be stored in an ion-rich aqueous solution. The sensitive gel layer of the pH-maintaining glass membrane contains high levels of water and ions, responding more reliably to sample pH.


    Specification:

    Modle
    ASP500-NYD05
    PH Range
    0~14pH 0.01pH
    Shaft Material
    ABS
    Working TEMP
    0~60℃
    Reference System
    double salt bridge
    Reference Electrode
    Ag/AgCl
    Electrolyte
    Gel
    Working Pressure
    0~4Bar
    Temperature Unit
    NTC10K
    Membrane
    Ceramic hole
    Glass Head

    Blue low impedance


    Dimension
    Diameter: 35mm Length: 260 mm ( include the cleaning cover)
    Thread Size
    1 inch NTP(both ends)
    Lead Wire
    Standard 5m
    Ground
    SUS316 solution
    Cleaning
    A protective cover with its own cleaning interface(Optional)
    Application
    Pure water

    Please click the catalog of pH controller here:

    Daruifuno Catalog.pdf


    Brief introduction:

    ◆ pH composite electrode, grounded with stainless steel solution, specially designed for accurate detection of pure water environment;
    ◆ Built-in high-precision NTC10K temperature resistance;
    ◆ The main body is packaged with reinforced plastic case
    ◆ The electrode is equipped with a protective cover with its own cleaning interface;
    ◆ Blue low-impedance hemispherical glass head;
    ◆ The reference adopts ring-shaped ceramic holes, the reference electrode is Ag/AgCl, and it is filled with KCL colorless high temperature gel;
    ◆ The reference system is designed with double salt bridges, and the ring-shaped ceramic holes have the characteristics of fast response, not easy to block, and easy to clean.

    Aplication:

    Water treatment monitoring

    Drinking water,surface water,water quality analyze,ground water,ect.


    Industrial process monitoring and dosing control

    Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


    FAQ

    1. What is themeasurement principle of this pH electrode?
    A:
    The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


    2. How is this glass pH electrode composed?
    A:
    The pH electrode is usually composed of an indicator electrode and a reference electrode.


    3. How to judge the pH of the solution?
    A:
    If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.


    4. What is the wire length of the pH electrode?
    A: The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.


    5. How often must the pH sensor be calibrated?
    A: Depends on the type of sample:
    Dirty samples and non-aqueous samples require more frequent calibration.
    Depends on the required accuracy:
    For very accurate measurements, at least daily calibration is required.
    Depends on the quality of the electrode:
    Old electrodes require more frequent calibration.

    Quality Flow Through Installation SUS316 Solution Ground PH Electrode For Pure Water for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more pH ORP Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0