Sign In | Join Free | My burrillandco.com
Home > Used Measuring & Analysing Instruments >

PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater

    Buy cheap PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater from wholesalers
     
    Buy cheap PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater from wholesalers
    • Buy cheap PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater from wholesalers
    • Buy cheap PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater from wholesalers
    • Buy cheap PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater from wholesalers
    • Buy cheap PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater from wholesalers

    PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : ASP400-TYD05
    Certification : CE
    Price : Negotiable
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-15 days
    • Product Details
    • Company Profile

    PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater

    PT1000 /PT100 Temp. Compensation pH sensor for wastewater


    Ph electrode reference junction blockage, electrolyte loss, glass bulb contamination, and use of the wrong calibration buffer can all lead to decreased electrode slope and performance. Temperature is also an important factor for electrodes. The potential of the electrode to measure the sample depends in part on the temperature of the sample. Compensation is possible because temperature is known to be linear to pH.


    The accuracy of the measurement is affected by many factors, including the accuracy of the buffers during calibration, whether temperature compensation is used, whether the appropriate electrodes are used, whether there is sufficient time to measure, whether the correct endpoint and measurement mode are selected, etc. When these factors are fully taken into account, there is a slight error in the accuracy of the measurements.


    Specification:

    Modle
    ASP 400-TYD05
    PH Range
    0~14pH 0.01pH
    Shaft Material
    PPS
    Working TEMP
    0~100℃
    Reference System
    double salt bridge
    Reference Electrode
    Ag/AgCl
    Electrolyte
    Crystal
    Working Pressure
    0~6Bar
    Temperature Unit
    PT1000/PT100
    Membrane
    Porous
    Glass Head

    Transparent low impedance


    Dimension
    Diameter: 35mm Length: 260 mm ( include the cleaning cover)
    Thread Size
    1 inch NTP(both ends)
    Lead Wire
    Standard 5m
    Ground
    --
    Cleaning
    A protective cover with its own cleaning interface(Optional)
    Application
    Sewage

    Please click the user manual of pH sensor here:

    ASP400T pH sensor technical data.pdf


    Brief introduction:

    ◆ pH composite electrode, the body adopts high-performance ABS plastic shell encapsulation
    ◆ Sturdy structure, with installation threads at the beginning and end, easy to install;
    ◆ The electrode is equipped with a protective cover with its own cleaning interface;
    ◆ The indicator electrode adopts a low-impedance hemispherical glass head, which has high strength and is not easily broken;
    ◆ The reference adopts a large-area annular porous membrane, which has fast penetration speed, fast response, not easy to block, and easy to clean;
    ◆ The reference system is designed with double salt bridge, the reference electrode is Ag/AgCl, and the reference is filled with saturated KCL+excess KCL crystal;

    Aplication:

    Water treatment monitoring

    Drinking water,surface water,water quality analyze,ground water,ect.


    Industrial process monitoring and dosing control

    Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


    FAQ

    1. What is themeasurement principle of this pH electrode?
    A:
    The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


    2. How is this glass pH electrode composed?
    A:
    The pH electrode is usually composed of an indicator electrode and a reference electrode.


    3. How to judge the pH of the solution?
    A:
    If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.


    4. What is the wire length of the pH electrode?
    A:
    The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.


    5. How often must the pH sensor be calibrated?
    A: Depends on the type of sample:
    Dirty samples and non-aqueous samples require more frequent calibration.
    Depends on the required accuracy:
    For very accurate measurements, at least daily calibration is required.
    Depends on the quality of the electrode:
    Old electrodes require more frequent calibration.

    Quality PT1000 /PT100 Temp. Compensation PH Sensor For Wastewater for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more pH ORP Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0