    Brand Name : Dwyer
    Model Number : DM-2000
    Certification : CCC.CE
    Price : usd35 piece/pieces
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    0-1250pa LCD Vertical Digital Pressure Gauge CCC 4-20mA DM-2000 Series

    Dwyer Differential Pressure Transmitter DM-2000 Series Digital differential pressure gauge for sale


    product description

    Dwyer series DM2000 differential pressure transmitter measures the pressure difference between air and compatible gases, and outputs a standard 4-20mA signal. The DM-2000 housing is specially designed and has the same mounting dimensions as the standard Magnehelic table. Various models are available for factory calibration according to specific ranges. The inherent pressure connection of the housing is glass filled plastic molded to make installation quick and easy. Digital buttons zero and SPAN simplify the calibration of typical rotary potentiometers. An optional 3.5-bit LCD display for craft and engineering units. A single button allows field selection of 4 to 6 engineering units depending on the range.


    Specifications

    Brand nameDwyer
    ModelDM-2000
    ServiceAir and non-combustible, compatible gases.
    Pressure range0-1250pa
    Accuracy±1% FS at 70°F.
    Stability±1% FS/yr
    Temperature Limits20 to 120°F (-6.67 to 48.9°C).
    Pressure Limits10 psig (0.69 bar).
    Power Requirements10 to 35 VDC (2 wire).
    Output Signal4 to 20 mA
    Zero and Span AdjustmentsDigital push-button zero and span
    Display3.5 digit LCD, 0.7˝ H
    Process Connections1/8˝ ID tubing.
    Current ConsumptionDC: 38 mA max
    Mounting OrientationVertical
    Weight4.8 oz (136 g).

    Features

    • Zero and span controls provide easy calibration checks and shorter installation time to get device running and monitoring

    • Quick response to pressure changes means no delay in signaling and alerting to critical situations

    • Easy to read LCD display provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread

    • Same size as Magnehelic simplifies field upgrade to digital pressure gage by reducing install steps

    • Tamper proof button configuration to prevent accidental changes to the settings

    Applications

    • Differential pressure across filters

    • Fan control

    • Static pressures in ducts or buildings

    • The bidirectional range is ideal for sensing fluctuations in building pressure

    Install

    1. Position

    select a clean and dry installation position without strong vibration, and keep the temperature between 20 and 120F (-6.7 to 48.9 ° c). The distance from the receiver is limited only to the loop impedance of the entire circuit, see electrical connections on the next page. The pressure tube connected to the meter can be of any length desired, but too long will increase the response time.

    2. Vertical

    installation is required in the direction, and all standard models are set in the vertical direction. Pressure connection housing with two conduit connections, design size suitable for 18" (3.12MN) I.D. The catheter. Make sure the pipe pressure level is higher than the operating pressure range.

    3. Mounting

    inserts - Make a 4-9/16" diameter round hole in the panel, insert the table and secure it with screws. Surface - Make 3 3/16" diameter screw holes in concentric circles of panel diameter 4-1/8", make holes as shown below, suitable for wiring installation.


    Model Chart


    Quality 0-1250pa LCD Vertical Digital Pressure Gauge CCC 4-20mA DM-2000 Series for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Mengchuan Instrument Co,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Digital Pressure Gauge products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0