Sign In | Join Free | My burrillandco.com
Home > Cleaning Equipments >

Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer

    Buy cheap Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer from wholesalers
     
    Buy cheap Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer from wholesalers
    • Buy cheap Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer from wholesalers
    • Buy cheap Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer from wholesalers

    Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer

    Ask Lasest Price
    Brand Name : Aloka
    Model Number : UST-9104-5
    Price : Negotiable
    Payment Terms : T/T, Western Union
    Delivery Time : 1-3 work days
    • Product Details
    • Company Profile

    Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer


    ALOKA UST-9104-5 Micro Convex Probe


    1. Type: Curved Array
    2. Frequency: 3.0 - 7.5 MHz.

    3. Application: Neonatal

    5. Compatible with Aloka SSD-900; Aloka SSD-1400; Aloka SSD-1700; Aloka SSD-1000; Aloka SSD-3500
    6. Warranty: 60 days
    7. Lead time:1-3 days




    Ultrasound Machine Maintenance


    1. Check the Ultrasound Machine Daily

    Before starting the examinations of your patients, ensure that all the connections of the ultrasound are plugged in properly. You should look carefully at the integrity of the ultrasound wiring, cables as well as transducers. If you find any cut or frayed areas, replace them with backup supplies immediately.


    2. Pay Attention to Your Ultrasound Transducers

    Ultrasound transducers are a vital part of a fully functional ultrasound unit. They need to be checked correctly to make sure that doctors can get precise examination results.

    Therefore, perform a visual check of the probe and its connection to the ultrasound machine before each use. Inspect if there are any cracks/cuts on the probe lens or on the TEE probe tube. That is important because ultrasound gel or disinfectant can easily seep into the cuts and potentially damage the transducer. Furthermore, look for tears in the cable that could indicate broken wires inside the transducer.

    Lastly, follow cleaning protocols, for instance, the sterilization of certain types of probes used for specific procedures. And be aware of the detergents your sonographer is using when cleaning and disinfecting the probes. Be sure that they are compatible with the probe manufacturer’s recommendations to avoid unwanted damages.


    Other Aloka probes we can offer:


    BrandModelCompatible System
    AlokaUST-979-3.5SSD-900/1000/1100/1400/1700/3500/4000
    AlokaUST-944B-3.5SSD-500/SSD- 620/SSD- 625/SSD-650/SSD-1100
    AlokaUST-669-5-7.5SSD-1000/ SSD -1700/ SSD -2200
    AlokaUST-984-5SSD-1000/SSD-1400/SSD-1700/SSD-5000/SSD-5500
    AlokaUST-9115-5SSD-5000/ Alpha 5/ Alpha 10
    AlokaUST-9116P-5SSD-1000
    AlokaUST-9118Alpha 5/Alpha 10/SSD-3500/SSD-4000/SSD-5500
    AlokaUST-9120Alpha 5/Alpha 7/Alpha 10
    AlokaUST-9121SSD-3500/SSD-4000
    AlokaUST-9123SSD-4000/ SSD-3500
    AlokaUST-9124SSD-3500/SSD-4000
    AlokaUST-9126SSD-5000/ SSD-5500/Alpha 5
    AlokaUST-9130Alpha 7/Alpha 10
    AlokaUST-5410HAlpha 5 Ver. 3.1 and above
    AlokaUST-5294SSD-5000
    AlokaUST-5546SSD-3500/SSD-4000
    AlokaUST-5266-3.5SSD-1700/SSD- 2000/SSD- 2200
    AlokaUST-5283-2.5SSD-2000/SSD-2200
    AlokaUST-5299SSD 3500/4000/Prosound Alpha 6
    AlokaUST-5412Alpha 5/Alpha 10/SSD-500V/SSD-5500
    AlokaUST-5413SSD-3500/SSD-4000
    AlokaUST-5518-7.5SSD-3500/SSD-4000
    AlokaUST-5524-7.5SSD-1000/1400/1700/5000/5500
    AlokaUST-5524-5SSD-1000/1400/1700/5000/5500
    AlokaUST-5536-7.5SSD-1700/SSD-2000/ProSound SSD-3500/ SSD-4000/ Alpha 5
    AlokaUST-5543Alpha 5/Alpha 10
    AlokaUST-5548Alpha 5SX/Alpha 7/Alpha 10/SSD-3500SX
    AlokaUST-5710-7.5SSD-900/SSD-1000/SSD-1400/SSD-1700/SSD-3500/SSD-4000/Alpha 5
    AlokaUST-5712Alpha 5/ Alpha 7/ Alpha 10
    AlokaUST-52101Alpha 5/Alpha 7/SSD-5500
    AlokaUST-52105Alpha 5/ Alpha 7/ Alpha 10
    AlokaUST-52108SSD-5500
    AlokaUST-52109Alpha 5/SSD-4000

    Quality Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Rongtao Medical Tech LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Ultrasound Scanner Probe products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0