Sign In | Join Free | My burrillandco.com
Home >

Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner

    Buy cheap Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner from wholesalers
     
    Buy cheap Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner from wholesalers
    • Buy cheap Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner from wholesalers

    Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner

    Ask Lasest Price
    Brand Name : Kingway
    Model Number : KW71NHCSW-1/2A
    Certification : CE, ISO, ROHS
    Payment Terms : L/C, T/T, Western Union, D/P
    Supply Ability : 300 Sets Per Year
    Delivery Time : 20 Working Days
    • Product Details
    • Company Profile

    Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner

    Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner


    What is a gas heat pump air conditioner?
    The gas heat pump air conditioner is an air conditioning unit that drives the compressor through a gas engine and circulates the gas heat pump for cooling or heating.


    The difference between the gas heat pump air unit and the air source heat pump air conditioner is: the gas V heat pump air conditioner uses the TN city gas as the energy source: the air source heat pump air conditioner is driven by the built-in motor of the compressor, driven by the gas engine, and uses the gas as the energy source: the work uses electricity as the energy source .Self-developed GHP special gas engine.


    ModelKW40NHCSW-1/1AKW65NHCSW-1/2AKW71NHCSW-1/2AKW120NHSW-1/2A
    Power supply1N~220V 50Hz1N~220V 50Hz1N~220V 50Hz1N~220V 50Hz

    Performance

    Nominal cooling capacity(KW)406571-
    Refrigeration condition heat recovery (KW)233740-
    Heating CapacityNominal Capacity (KW)457380120
    Low Temperature (KW)457380120
    Gas consumption (low calorific value)Gas typeNatural gasNatural gasNatural gasNatural gas
    Nominal cooling (KW)33.754.859.9-
    Nominal heating (KW)33.955.160.265
    Electrical CharacteristicsRefrigerationRunning current (A)4.687.608.30-
    Power consumption (KW)0.951.541.68-
    HeatingRunning current (A)4.397.147.8012
    Power consumption (KW)0.881.441.572.1
    Water flowRefrigeration (M3/h)6.8811.1812.21-
    Heating (M3/h)6.8811.1812.2120.64
    Domestic hot water (M3/h)3.886.306.88-
    CompressorTypeVortex *1Vortex *2Vortex *2Vortex *2
    Displacement86.286.286.286.2
    Lubricant grade (Cm3/rev)FVC68DFVC68DFVC68DFVC68D
    Refrigerator oil charge (L)2*12*22*22*2
    Crankshaft heating belt (W)40*140*240*240*2

    Engine


    Range of rotation (RPM)1000~23001000~23001000~23001000~2300
    Displacement (cc)2300230023002300
    Engine oil grade5W-405W-405W-405W-40
    Lubricating oil charge (L)23454545
    Start methodDC Electric StartDC Electric StartDC Electric StartDC Electric Start
    Engine cooling waterPump power (W)152252252252
    Charge (L)20323232
    Concentration, freezing temperature50V/V%~ -35°C50V/V%~ -35°C50V/V%~ -35°C50V/V%~ -35°C
    Refrigerant (R410A charge) Kg1110*210.5*210.5*2
    DimensionsHigh (mm)2296229622962296
    Width (mm)1006100610061006
    Long (mm)1436200620062006
    Weight (Kg)600900010001000
    Maximum water resistance (Kpa)50505050
    Piping interfaceAir conditioning water pipeDN40 flangeDN50 flangeDN50 flangeDN50 flange
    Domestic hot water pipeG1-1/4” inner screwG1-1/4” inner screwG1-1/4” inner screwG1-1/4” inner screw
    Gas piping (mm)Rc1/2”Rc3/4”Rc3/4”Rc3/4”
    Running noise dB (A)60616262
    FanAir supply formAxial Fan*1Axial Fan*2Axial Fan*2Axial Fan*2
    Rated air volume M3/h1500250002700027000

    Remark:

    1. Refrigeration: The outdoor temperature is 35°C, and the outlet water temperature is 7°C. When the outlet water temperature is lower than 5°C during operation, antifreeze must be used as the refrigerant water.

    2. The amount of heat recovery under refrigeration conditions: the outlet water temperature is 45°C. (Please note that this function is required when ordering)

    3. Heating (nominal): outdoor temperature 7/6°C, outlet water temperature 45°C; heating (low temperature): outdoor temperature 2/1°C, outlet water temperature 45°C.

    4. The type of gas is natural gas, and the pressure is low pressure. (Maximum pressure: 2.5kpa; Standard pressure: 2.0kpa; Minimum pressure 1.0kpa)

    5. Actual gas consumption (Nm3/h) = gas consumption (kW) X3.6/35.4 (MJ/Nm3)

    6. If the product is updated, the data is subject to change without prior notice.

    Quality Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Qingdao Kingway Industry Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Gas Generator products from this supplier
    Inquiry Cart 0