Sign In | Join Free | My burrillandco.com
Home > Medical Devices >

GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7

    Buy cheap GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 from wholesalers
     
    Buy cheap GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 from wholesalers
    • Buy cheap GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 from wholesalers
    • Buy cheap GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 from wholesalers
    • Buy cheap GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 from wholesalers
    • Buy cheap GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 from wholesalers

    GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7

    Ask Lasest Price
    Brand Name : GE
    Model Number : 3Sc-RS
    Payment Terms : T/T, Western Union,PayPal
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7


    GE Ultransound 3Sc-RS PHiliphhilipased Array probe for Vivid S60 Vivid T8 Vivid S5 Vivid iq Vivid i LOGIQ P9 LOGIQ e LOGIQ e R7


    Brief Introduction

    GE 3Sc-RS Wide Band PHiliphhilipased Array Probe is Applications: Abdomen, Obstetrics, Gynecology, Basic Cardiac, fetal heart, Vascular, Urology, Pediatric/Neonatal, transcranial, coronary, stress, LVO contrast, LVO stress, vascular, ED (FAST, Pleural, Orbits).

    Helps improve near field imaging, decreases vessel fill-in, increases contrast and detail resolution and helps provide optimized imaging.


    Excellent contrast resolution is identified scanning the heart


    Adult Echo Color Doppler - The 3Sc PHiliphhilipased array cardiac probe combines acoustic amplifier technology and an advanced heat dissipation regime to provide ultra-wide bandwith and highend image quality.


    Specifications


    Main ApplicationsDescriptionModeFootprintBiopsy GuideScanner Frequency RangeField of ViewDepth of Field
    Cardiac, Pediatric, Abdominal, Fetal, Adult CePHiliphhilipalicPHiliphhilipased Array2D-Mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler
    18 x 24 mmMulti-angle disposable, with a reusable bracket1.3 - 4.0 MHz120°30 cm

    The 3Sc-RS probe is compatible with:

    • Vivid S60
    • Vivid T8
    • Vivid S5
    • Vivid iq
    • Vivid i
    • LOGIQ P9
    • LOGIQ e
    • LOGIQ e R7

    Connect the probe

    Probes can be connected at any time, whether the system is on or off.

    1. Before connecting the probe:

    • Inspect the probe and the probe cable for any damage.

    • Do a visual check of the probe pins and system sockets. Remove any dust or foam remains from the probe pins.

    1. Hold the probe connector vertically with the cable pointing upward.
    2. Turn the connector locking handle counterclockwise.
    3. Align the connector with the probe port and carefully push into place.
    4. Turn the locking handle clockwise to the full vertical position to lock in place.
    5. Position the probe cable so that it is not resting on the floor.

    ► Probe Manual Cleaning Instructions

    1. Put on a clean pair of gloves and fill a sink or basin with warm potable water (30 - 40°C) to a level allowing immersion of the probe up to the immersion line shown.
    2. Prepare the cleaning solution in accordance with the disinfectant manufacturer’s instructions.
    3. Immerse the probe in the prepared cleaning solution up to the immersion line and ensure no air bubbles are trapped on the surface. Do not submerge probe beyond the immersion line shown.

    Storing probes
    It is recommended that all probes be stored in the carrying case provided.

    • First place the probe connector into the carrying case.
    • Carefully wind the cable into the carrying case.
    • Carefully place the probe head into the carrying case. DO NOT use excessive force or impact the probe face.

    For any additional questions or concerns regarding GE Ultransound 3Sc-RS PHiliphhilipased Array probe for Vivid S60 Vivid T8 Vivid S5 Vivid iq Vivid i LOGIQ P9 LOGIQ e LOGIQ e R7, please feel free to contact us.If you want to explore more details please let us know.


    Quality GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Used Ultrasound Transducer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0