Chinese Dental Handpiece/Dental Hand Piece High Speed Dental Handpiece
Dental Handpiece Led Features:
The dental handpiece LED high speed handpiece & swivel with inbuilt
generator creates LED light in the mouth.
Simple FG bur changing
Precision bur cooling – triple coolant spray produces a mist around
the bur.
Patented hygienic head – Prevents aerosol particles from being
sucked into the turbine.
1 year warranty.
1.Low noise,Standard head
2.Triple water spray, LED handpiece integrate E-generator
3.4-Hole/2-Hole Push Button system
4.Unique electric generator, just a little air can generate
sufficient power
5. 135°C Autoclavable
6. For the LED bulb, continuous use of up to ten thousand hours,
don't need to change the pipeline, easy to use; The world dental
chair two holes, four holes. 7.Warranty:one year for handle; three
months for cartridge
Dental Led Handpiece Tech data:
| Product name | Dental Handpiece Led | 
| Drive air pressure | 0.25-0.3Mpa | 
| Water pressure | 0.2Mpa | 
| Water pressure | 198Kpa(2kg) | 
| Light brightness | 25500lux | 
| Power | 22W | 
| Rotation speed | 350,000~420,000rpm | 
| Head height | 13.0mm | 
| Head diameter | Φ11mm | 
| Chuck type | Push button | 
| Clamping force | 22N~34N | 
| Torque force | 0.1N·cm(small head); ≥0.1N·cm(large head) | 
| Bur Applicable | Φ1.59mm-Φ1.60mm*21mm-23mm(diameter*length) | 
| Noise | ≤60DB | 
Why choose us?
We are manufacturer for producing and supplying high speed dental
handpiece , low speed dental handpiece, dental implant handpiece,
endodontic files, and other relative dental instruments for many
years .OEM & ODM orders are available , if you do not find the right items you are looking for,kindly
please leave us message , we will reply you within 24hours .Thanks!
After each patient use , maintenance should be done as follows:
1. First remove the diamond burs , and clean up all the teeth on
dental handpieces precipitate
2. Use a metal needle to clean the spray holes and fumaroles
Note: The spray holes and diamond burs into 40 -degree angle ,
fumaroles and diamond burs to a 30 degree angle
3. Place the clean lubricating oil is sprayed into the axial hole
1-2 seconds ( diamond burs is plugged holes )
4. In the bottom of the handpiece were ( with / without quick
connector ) two kinds of styling , make the right amount of
lubricant is injected into the bottom
5. The handpiece with quick connector combination ( first determine
the water switch is turned off )
6. Replace the diamond burs , surrounded by white silk cloth
handpiece head ( make sure the needle does not touch the diamond
burs and white gauze , so as not to tie )
7. pedal depressed for about 20 seconds , look at whether there is
in white gauze on any stain. If there are stains on the white gauze
, again, add oil , starting from item 4 continued routine
maintenance , know that white gauze until no stain
8. Finally, no more than 135 degrees Celsius temperature and high
pressure sterilization
|   | 
 
                                 
                                 
                                 
                                