75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

    Buy cheap 75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers from wholesalers
     
    Buy cheap 75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers from wholesalers
    • Buy cheap 75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers from wholesalers
    • Buy cheap 75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers from wholesalers
    • Buy cheap 75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers from wholesalers

    75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

    Ask Lasest Price
    Brand Name : Coolent
    Model Number : CYAT76-90
    Certification : ISO/CE
    Price : to be Negotiated
    Payment Terms : T/T
    Supply Ability : 1000/Month
    Delivery Time : 4W
    • Product Details
    • Company Profile

    75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

    75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers


    Product Introduction

    Coolnet server air conditioners series can be used in precision environmental adjustments in big, small and medium computer rooms, battery rooms, equipment rooms and other places. The unit adopts advanced design concepts with strictly tested by precision air-conditioning professional laboratories. It has high efficiency, energy saving, stability and long life. It has operating characteristics, and has constant temperature and humidity adjustment functions, which can meet the precise environmental adjustment needs of different industries such as IT, electric power, finance, medical laboratories and transportation.


    Benefits


    Applications

      • Computer room and data center
      • Switch room and mobile center station in telecommunication
      • High-tech environment and lab
      • Industrial automation control room and precision manufacturing workshop
      • Standard test room and calibration center
      • UPS and battery room
      • Test room in hospital
      • Biochemical culture chamber

      Technical Features


      High sensible heat
      The host and peripherals, servers, switches, optical transceivers and other computer equipment installed in the computer room, as well as power support equipment, such as UPS power supply, will dissipate heat into the computer room by means of heat transfer, convection, and radiation. These heat only cause the temperature in the computer room. The increase is sensible heat. The heat dissipation of a server cabinet ranges from a few kilowatts to a dozen kilowatts per hour. If a blade server is installed, the heat dissipation will be higher. The heat dissipation of large and medium-sized computer room equipment is about 400W/m2, and the data center with higher installed density may reach more than 600W/m2. The sensible heat ratio in the computer room can be as high as 95%.


      Low latent heat
      It does not change the temperature in the computer room, but only changes the moisture content of the air in the computer room. This part of the heat is called latent heat. There is no humidity dissipation device in the computer room, and the latent heat mainly comes from the staff and the outdoor air, while the large and medium-sized computer room generally adopts the management mode of man-machine separation. Therefore, the latent heat in the engine room is small.


      Uninterrupted operation, year-round cooling
      The heat dissipation of the equipment in the computer room is a steady heat source and operates uninterrupted throughout the year. This requires a set of uninterrupted air conditioning guarantee system, and there are also high requirements on the power supply of the air conditioning equipment. And for the air-conditioning system that protects important computer equipment, there should also be a generator set as a backup power supply. The long-term steady-state heat source causes the need for cooling even in winter, especially in the southern region. In the northern region, if cooling is still required in winter, the condensing pressure of the unit and other related issues need to be considered when selecting an air-conditioning unit. In addition, the proportion of outdoor cold air intake can be increased to achieve the purpose of energy saving.


      Technical Parameters


      Model: CYAT26D/UT31D/UT35D/UT41D/UT45D/UT50D/UT55D/UT61D/UT70D/UT76D/UT85D/UT90D/UT100D/U
      Power Supply380V 3Ph-50HZ
      Air DischargeUpflow/Downflow
      Cooling Capacity :24℃/50%RH
      Total Capacity (1)KW26.931.935.941.945.350.555.461.470.576.285.590.8102
      SensibleKW24.829.533.138.842.547.851.657.565.271.279.584.595.7
      AEERW/W3.63.63.63.63.63.73.73.63.63.63.63.63.6
      Air Flowm3/h800095001000011500130001550016000175001850020500225002350024200
      Compressor Hermetic scroll
      RefrigerantR407C
      Compressor quantityPC2222222222222
      Fan Section Centrifugal fan (Optional EC)
      Fan quantityPC2222222223333
      Rated currentA4.34.34.34.44.44.455.25.26.516.516.516.5
      Rated powerW1600160018001800200020003000330039003900540063006300
      Total heating capacityKW66699999912121212
      MaterialPTC
      Humidifier Section Electrode type
      CapacityKg/h5555131313131313131313
      Rated CurrentA6666151515151515151515
      Condenser Model2*582*582*582*582*802*802*1002*1002*1202*1502*1502*1652*180

      Certificates


      Factory Details


      Packing & Delivery


      Case


      Quality 75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers for sale
      • Haven't found right suppliers
      • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
      • And this service is free of charge.
      • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
      Submit Buying Request
      Send your message to this supplier
      *From:
      Your email address is incorrect!
      *Subject:
      Your subject must be between 10-255 characters!
      *Message:
      For the best results, we recommend including the following details:
      • --Self introduction
      • --Required specifications
      • --Inquire about price/MOQ
      Your message must be between 20-3,000
      Yes! I would like your verified suppliers matching service!
      Send your message to this supplier
       
      *From:
      *To: Hefei Coolnet power Co., ltd
      *Subject:
      *Message:
      Characters Remaining: (0/3000)
       
      Explore more Precision Air Conditioning Units products from this supplier
      Inquiry Cart 0