    Brand Name : YOMIN
    Model Number : YMLZ-0.5S
    Supply Ability : 100000 Piece/Pieces per Month
    Price : $2.08 - $5.00/Pieces
    • Product Details
    • Company Profile

    400/5A resin type class 0.5 Current Transformer

    400/5A resin type class 0.5 Current Transformer

    Model: YMLZ-0.5S


    Product Overview

    Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They're connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT.




    • Measuring CT: Measuring current transformers are constructed to feed on other low voltage apparatus such as measuring instruments, relays, watt-hour meter (KW meter) and these type of current transformers are mainly used 0.5 and 1.0 class to transfer the current from highest rated current to rated secondary current.

    • Protection CT: Protection current transformers are constructed to feed the protection relay. These type of current transformers are mainly used 5P.


    Selection of the Current Transformer

    To select the current transformer correctly, the following points should be clarified:

    • -The application (for measuring or protection).
    • -The features of the working environment (Indoor or outdoor, operating temperature, air humidity etc….).
    • -Operation voltage and frequency.
    • -Range of the primary current (maximum and minimum of the current to be measured).
    • -Dimension of the cable or Bus bar.
    • -Data of the overload.
    • -Short circuit current.
    • -Specification of the measuring device associated with the current transformer (Accuracy, rated current, consumption etc…).
    • -The diameter and length of the cable, the cable which is used to connect the current transformer and associated measuring device.



    Accuracy of A Current Transformer

    The percentage of error, produced in a transformer, is established by IEC60044-1. In measurement transformer: 25% and 100% of nominal power. In protection transformers: 100% of nominal power.


    Note: with…/1A transformers losses are reduced 25 times.



    Saturated Condition of CT

    The current transformer is saturated if the primary current, passing through the CT, is greater than the nominal rating of the CT.


    The linearity of CT, between the primary and secondary sides decreases, so error increases. The saturation of the CT is inversely proportional to the load (FIG. 1).


    The difference between measuring and protection current transformers is their behavior when an overload occurs on the primary side. Measuring CT is saturated when there is a primary current overload. In order to protect the equipment. On the secondary side, protection CT will not saturated until there is a very high current on the primary side, A class 5P15 protection transformer indicates that it has an accuracy rating of ±1% that it does not become saturated until the primary current reaches 15 times the nominal current rating of the CT.

    In measuring transformers, the SAFETY FACTOR “FS” parameter indicates the excessive amperage on the primary side current in relation to the current sent to the measuring device on the secondary side.


    Application Note

    If the primary current is too small, to keep the same accuracy and output, we can add primary winding, but the rated turns ration should be the same, For example, if the primary current is 50A, we can use 100/5A current transformer with the primary current be turned twice which help to keep the same rated turns ratio (1:50 = 2:100).



    Construction



    CT consist of primary winding, secondary winding, magnetic core and insulated body. The high-grade silicon steel core is annealed, varnished then insulated with polycarbonate core caps. The secondary winding is toroidally wound by high precision semi-automatic machinery. For the tape wound ring type current transformer, the PEW coated windings are then covered with elephantite paper, varnished and double-tapped with PVS tapes. For the encapsulated type current transformer, the windings are enclosed in a compact and heat resistant split cap.


    Specifications

    • Current Ratio..................................................................................400/5A
    • Accuracy.........................................................................................Class 0.5
    • Burden.............................................................................................See Selection Form.
    • Security Factor................................................................................FS<5
    • Max System Voltage.......................................................................720V AC
    • Test Voltage.....................................................................................3kV AC. (1 min.)
    • Frequency........................................................................................50/60Hz
    • Rated Short-time Thermal Current (Ith)........................................Ith = 60 X In
    • Rated Dynamic Current (Idyn).......................................................Idyn = 2.5 X Ith
    • Continuous Overload.....................................................................1.2 X In
    • Working Temperature....................................................................-25°C ~ +50°C
    • insulation Rating.............................................................................Class B
    • Housing Self-extinguishing Class.................................................VO.
    • Bus-bar Support Mounting.............................................................Provided.
    • Panel Mounting................................................................................Provided.
    • Hinged Sealable Terminal Cover....................................................No Provided.
    • Standards.........................................................................................IEC/EN60044-1, VDE0414-44-1, BS3938, BS7626
    • Item Condition..................................................................................Brand New.
    • Quality Assurance...........................................................................24 Months.
    • Sample Service................................................................................Provided.

    Selection Form

    ItemCurrent RatioRated Burden (VA)Case Qty.
    Model(A)Class: 0.5Class: 1.0(Pcs)
    DP-23200/5-1.520
    250/5-2.520
    300/51.52.520
    400/52.53.7520

    Company Information


    Quality 400/5A resin type class 0.5 Current Transformer for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Yueqing Yomin Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Current Transformer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0