Sign In | Join Free | My burrillandco.com
Home > Power Distribution Equipment >

50W 3 Phase Integrated Capacitor Low Voltage Products Compensation Intelligent

    Buy cheap 50W 3 Phase Integrated Capacitor Low Voltage Products Compensation Intelligent from wholesalers
     
    Buy cheap 50W 3 Phase Integrated Capacitor Low Voltage Products Compensation Intelligent from wholesalers
    • Buy cheap 50W 3 Phase Integrated Capacitor Low Voltage Products Compensation Intelligent from wholesalers
    • Buy cheap 50W 3 Phase Integrated Capacitor Low Voltage Products Compensation Intelligent from wholesalers

    50W 3 Phase Integrated Capacitor Low Voltage Products Compensation Intelligent

    Ask Lasest Price
    Brand Name : BAIKONG
    Certification : IEC,GB
    Price : $100-$1000/PCS
    Payment Terms : L/C, Western Union, T/T
    Supply Ability : 300 sets/sets per week
    Delivery Time : 15Days OR To be negotiated
    • Product Details
    • Company Profile

    50W 3 Phase Integrated Capacitor Low Voltage Products Compensation Intelligent

    Three Phase Compensation Intelligent Integrated Low-Voltage Power Capacitor


    Code and implication



    Technical parameters


    • Parameters

    Rated voltage: AC400V (deviation≤±10%,

    Sine wave total distortion rate <5%)

    Rated current: AC0~5A (current harmonic <10%,

    current input impedance ≤0. 02Ω)

    Operating freq: 50Hz; Standby power: <0.5W


    • Measurement accuracy

    Voltage≤0. 5%; Current≤0. 5%; Power≤0.5%;

    Power factor ±0. 01%; Temperature ±1℃;

    Time≤100ms


    • Data of connecting with system

    Maxi qty connected with system: ≤99PCS;

    Initialized time of connecting with system: ≤10s


    • Ambient operating conditions

    Ambient temperature: -30~+60℃

    Relative humidity: 90%RH (No dew at 20℃)

    • Parameter of reactive power compensation

    Interval between switching on/off: single piece ≥20s

    (increase if more pieces operated together)

    Maxi capacity of single capacitor:

    three-phase compensated together (30+30) kVar;

    three-phase compensated respectively 30kVar;

    • Other parameters

    Capacitor attenuation rate: ≤0. 5%/ year,

    failure rate: ≤5%/year (servicing 6000h)

    Permissible switching times: 106;

    protective breaking capacity: 120KA.

    Comm.port: RS485


    Performance and Feature


    • Intelligent monitoring system

    Acquisition of current, voltage, rely on 32-bit plug-in type MCU made by ST America,which can perform quick sampling,the transfer time of 12-bit AD need1uS only,these can realize high accurate measurement and calculation of 3-P current, 3-pvoltage, 3-P active power,reactive power,transparent power and etc,calculation and analysis of harmonics.

    • HMI system

    Monitor is LCD with 128X64 matrix, Chinese language,display the time,inside temperature,current,voltage,harmonic parameters at real time, check other parameters,operation status through keys,also the values of over-voltage,under-voltage,under-current, over-temperature,over-compensation can be set and saved,data not lost in case of power failure.

    • Intelligent connection with power system

    The product provides RS485 port,built-in MODBUS.RTU protocol,compatible with DL645-2007 protocol,able to perform remote monitoring and controlling. When more than one product connected with system,they will have one master machine among them automatically.others as slave machines,become automatic control system of reactive power compensation, any of individual one has fault,it will stop running, does not influence on others operating;if the master machine has fault and out of operation,they will produce new master machine automatically,form a new system.

    • Power capacitor

    Hi-performance dry type cylinder-shaped self-healing power capacity,has the merits of well radiation,small size,long service life,ensure the safety and reliability.

    • Fused disconnector.

    The general switch cooperated with high breaking fused disconnector is able to break 120KA short circuit current,large break position,to ensure the product able to isolate from system quickly and safely.


    Wiring


    1. The two shall be connected according to the power supply and load sign on the leakage breaker and shall not be reversed.

    2. The protection line shall not pass through the zero-order current transformer. When the three-phase five-line system or the single-phase three-line system is adopted, the protection line must be connected to the protection main line at the inlet end of the leakage circuit breaker, and shall not pass through the zero-order current transformer midway.

    3. Single-phase lighting circuit, three-phase four-line production and distribution lines, and other lines or equipment using the working zero line, the zero line must pass through the zero-order current transformer.

    4. In the system with the direct grounding of the neutral point of the transformer, once the leakage circuit breaker is installed, the working zero line can only be used as the working zero line after passing through the zero-order current transformer, and the grounding cannot be repeated or connected with the working zero line of other lines.

    5. The electrical equipment can only be connected to the load side of the leakage circuit breaker, and do not allow one end to be connected to the load side, while the other end is connected to the power supply side.

    6. In the lines with the single-phase and the three-phase load mixed under the three-phase four-line system or the three-phase five-line system, the three-phase load should be balanced as far as possible.


    Common fault


    Put into the trip


    1) The three-phase power line, including the zero line, does not cross the zero-order current transformer in the same direction, and the wiring can be corrected.

    2) The leakage circuit breaker and the unleakage circuit breaker are electrical connected, and the two circuits can be divided.

    3) There is a fire load in the line, so that such a load can be eliminated.

    4) Work zero line through the zero-order current transformer has repeated grounding phenomenon, and repeated grounding shall be eliminated.

    5) The leakage circuit breaker itself has a fault, and should be replaced.

    Quality 50W 3 Phase Integrated Capacitor Low Voltage Products Compensation Intelligent for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Sichuan Baikong Electric Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Low Voltage Products products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0