    Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : DPH790-YD01A
    Certification : CE, ISO
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-25 days
    • Product Details
    • Company Profile

    Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring


    Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring



    The digital pH sensor adopts the classic electrochemical principle, which is reliable in measurement and stable in performance. It is widely used in environmental protection water treatment, surface water, purified water, circulating water and other systems, as well as electroplating, electronics, printing and dyeing, chemical, food, pharmaceutical and other process fields. Excellent performance in sewage treatment, drinking water treatment, surface water monitoring, pollution source monitoring, industrial process and other applications.

    In order to obtain the best measurement results, regular maintenance is required. Maintenance includes cleaning of electrodes and checking for damage. Check whether the electrode wiring is correct, check the communication setting parameters (address, baud rate, parity bit, stop bit), etc.


    Specification:

    ModelDPH79
    Electrical Isolation
    Measuring RangePH: 0~14pH TEMP: 0~50℃
    Resolution0.01pH/0.1℃
    Accuracy±0.02pH
    Temperature CompensationAutomatic, built-in temperature unit
    Calibration MethodZero position/slope/deviation
    Work Pressure0~2Bar
    Operating Temperature0.0~50.0℃
    Shell MaterialABS
    DimensionDiameter: 35mm Total length: 260 mm ( include cleaning cover)
    Installation Size

    1"NPT at both ends of the installation thread;
    insertion depth 100 (including cleaning plug 115)

    Protection GradeIP68
    Weight150g

    Please click the user manual of RS485 pH sensor here:
    DPH7 digital pH User Manual.pdf

    Features& Advantages

    ● All-in-one package, can be used with the online transmitters, DTU, and portable instruments
    ● RS485 interface, Modbus RTU, support access to standard industrial control system
    ● The protection grade is IP68, can work continuously and stably under water for a long time
    ● Internal storage of calibration data, support offline calibration, plug and play on site




    Aplication:

    Water treatment monitoring
    Drinking water,surface water,water quality analyze,ground water,ect.

    Industrial process monitoring and dosing control
    Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


    FAQ
    1. What is the measurement principle of this pH electrode?

    A: The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.

    2. How to judge the pH of the solution?
    A: If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.

    3. What is the wire length of the pH electrode?
    A: The lead wire of this electrode is 1 m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

    4. How often must the pH sensor be calibrated?
    A: Depends on the type of sample:
    Dirty samples and non-aqueous samples require more frequent calibration.
    Depends on the required accuracy:
    For very accurate measurements, at least daily calibration is required.
    Depends on the quality of the electrode:
    Old electrodes require more frequent calibration.
    Quality Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more pH ORP Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0