Sign In | Join Free | My burrillandco.com
Home > Fuses >

20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager

    Buy cheap 20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager from wholesalers
     
    Buy cheap 20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager from wholesalers
    • Buy cheap 20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager from wholesalers
    • Buy cheap 20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager from wholesalers
    • Buy cheap 20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager from wholesalers
    • Buy cheap 20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager from wholesalers
    • Buy cheap 20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager from wholesalers

    20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager

    Ask Lasest Price
    Brand Name : AMPFORT
    Model Number : Y 20A 250V
    Certification : CCC,CQC,UL
    Price : Negotiable
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 500000pcs per day
    Delivery Time : 7 workdays
    • Product Details
    • Company Profile

    20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager


    Plastic Square Shell Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff For Fitness Massager


    Application Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff


    ● Electric Blankets
    ● Electric Aroma Diffusers
    ● Home Electrical Appliances
    ● Motors
    ● Lamps
    ● Switched-Mode Power Supplies
    ● Transformers


    Electrical Performances Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff


    P/N

    Rated operating temperature

    Tf(℃)

    Actual operating temperature

    (℃)

    Hold temperature

    Tc(℃)

    Limit temperature

    Tm(℃)

    Rated Voltage

    (V)

    Rated Current

    (A)

    Y1010298±17215025020
    Y20115111±18715025020
    Y30125121±29515025020
    Y35130126±110215025020
    Y50150146±212018025020

    Dimension Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff (mm)


    ABCDE※
    11±0.512±0.24.9±0.21.2±0.0545±2

    Length can be customized on request


    Usage Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff


    1. When atmosphere pressure is from 80 kPa to 106 kPa, the related altitude shall be from 2000 meter to -500 meter.

    2. Operating voltage less than rated voltage of ATCO, operating current less than rated current of ATCO.

    3. Do not touch the ATCO body or lead wires directly when power is on, to avoid burn or electric shock.


    Replacement Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff


    ATCO is a non-repairable product. For safety sake, it shall be replaced by an equivalent ATCO from the same manufacturer, and mounted in the same way.


    Storage Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff


    Do not store the ATCO at the high Temp., high humidity or corrosive gas environment, avoid influencing the solder-ability of the lead wires, the product shall be used up within 1 year after receiving the goods.


    Installation Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff


    Make Sure the Temp. of Installation Position.

    1. It is recommended that a dummy ATCO with inbuilt thermo-couple shall be used to determine the proper Temp.

    2. The terminal product should be tested to ensure that potential abnormal conditions do not cause ambient Temp. to exceed the Tm of the ATCO.

    3. Mount the ATCO at the location where Temp. rises evenly.

    4. The surface Temp. of TCO less than the holding temp of ATCO.

    5. The seal or body of TCO must not be burned or over heated.


    Installation position of mechanical performance requirements.

    1. Do not locate the ATCO in a place where severe vibration always occurs.

    2. Ensure that the lead wire is long enough, and avoid actions such as press, tensile or twist.

    3. The seal or body of TCO must not be damaged.


    Glossary Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff


    TCO

    Thermal-Link

    A non-resettable device incorporating a THERMAL ELEMENT which will open a circuit once only when exposed for a sufficient length of time to a temperature in excess of that for which it has been designed.


    ATCO

    Alloy Thermal-Link

    Alloy Type Thermal-Link, Alloy is the thermal element.


    Tf

    Rated Functioning Temp.

    The temperature of the Alloy Thermal-Link which causes it to change the state of conductivity with a detection current up to 10 mA as the only load.


    Tolerance: Tf + 0 / - 10 °C (GB 9816.1, EN 60691, K60691).

    Tolerance: Tf ± 7 °C (J60691).


    Fusing Temp.

    The temperature of the Alloy Thermal-Link which causes it to change its state of conductivity is measured with silicone oil bath in which the temperature is increased at the rate of 0.5 °C to 1 °C / minute, with a detection

    current up to 10 mA as the only load.


    Th

    Holding Temp.

    The Maximum temperature at which a Alloy Thermal-Link will not change its state of conductivity when

    conducting rated current for 168 hours.


    Tm

    Maximum Temp. Limit

    The temperature of the Alloy Thermal-Link stated by the manufacturer, up to which the mechanical and electrical properties of the Alloy Thermal-Link having changed its state of conductivity, will not be impaired for a given time.


    Ir

    Rated Current

    The current used to classify a Alloy Thermal-Link, which is the Maximum current that Alloy Thermal-Link allows to carry and is able to cut off the circuit safely.


    Ur

    Rated Voltage

    The voltage used to classify a Alloy Thermal-Link, which is the Maximum voltage that Alloy Thermal-Link allows to carry and is able to cut off the circuit safely.


    In

    Nominal Discharge Current

    Being able to withstand 15 peak currents of waveform 8 / 20 μs to test the product's durability of withstanding pulse current.


    Imax

    Maximum Discharge Current

    Bing able to withstand 1 peak current of waveform 8 / 20 μs to test maximum pulse current that the product can with stand.


    CP Wire

    Tinned Copper Plated Wire


    More Products Of The Thermal Links 20A 250V 102C 115C 125C 130C 150C Cutoff


    Quality 20A 250V Thermal Cutoff Fuse 102C 115C 125C 130C 150C For Fitness Massager for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Dongguan Ampfort Electronics Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Thermal Cutoff Fuse products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0