    Digital Fluorescence Method 18~36VDC Dissolved Oxygen Controller For Waste Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : DUC2-DO-H-D
    Certification : CE, ISO
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-25 days
    • Product Details
    • Company Profile

    Digital Fluorescence Method 18~36VDC Dissolved Oxygen Controller For Waste Water


    Digital Fluorescence Method 18~36VDC Dissolved Oxygen Controller For Waste Water


    Dissolved oxygen (abbreviated as DO) refers to the content of oxygen dissolved in water, usually in units of ppm or mg/l, ppb or ug/l.


    Specification:

    ModelDUC2-DO-H-D
    Software VersionDRFN DO Analysis software V1.0
    Sensor InputCompatible with all DRFN's DO Digital Sensors
    Display RangeDO ConcentrationDO concentration 0-50mg/L (or ppm), unit can be switched
    Saturation0-400%
    TEMP-10~500℃ /14~932℉
    Atmospheric Pressure30-120kpa
    ResolutionDO Concentration0.01 mg/L(or ppm)
    Saturation1%
    TEMP0.1℃/ 0.1℉
    Salinity Compensation RangeInput range 0.0001-99999ppt
    Relay Control2 settable SPST relays with a maximum load of 3A/250VAC
    Analog Current Output2 settable 0/4~20mA current outputs, max load 1000Ω
    Communication Method

    RS485 interface

    MODBUS RTU

    support JSON text data format

    OTA——
    Display Screen128*64 LCD, adjustable backlight mode, adjustable display rate
    Configuration InformationPower off protection, parameters are retained indefinitely
    Time/Data Record

    Record 14000 historical data

    Record interval can be set between 1~999 minutes

    Maintenance RecordsLast 100
    Operating Temperature0~60℃,RH<95% ( no condensation)
    Storage Temperature-20~70℃, RH<55% ( no condensation, precision instruments)
    Shell MaterialEnhanced ABS
    Protection GradeIP66
    Dimension144*144*120 mm
    Mounting MethodWall mounting, pipe clamping, panel (hole size 138*138 mm)
    Electrical InterfaceThe back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
    Power Supply18~36VDC
    Power ConsumptionAbout 7W
    WeightAbout 800g

    Please click the user manual of DO controller here:

    DUC2-DO User Manual.pdf


    Features& Advantages

    ● Compatible with DRFN digital dissolved oxygen sensors including fluorescence and polarography;

    ● Automatic compensation for air pressure display;

    ● The working status of the sensor can be queried, including reading the serial number;

    ● OTA download technology as a smart configuration option for the instrument;

    ● Time and historical data recording function;

    ● 3.2-inch large LCD screen;

    ● User-friendly Chinese and English language interface;

    ● Password can be set to prevent misoperation;

    ● 2 SPST multi-function and settable relays;

    ● Two 0/4~20mA active current loop outputs;

    ● RS485 interface, Modbus RTU communication protocol;

    ● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

    ● Support a variety of installation methods.

    Aplication:
    ◇ Sewage
    ◇ Surface water monitoring
    ◇ Aquaculture water bodies
    ◇ Urban sewage treatment
    ◇ Industrial wastewater treatment
    ◇ Aquarium


    FAQ
    1. Which sensors can be connected to your dissolved oxygen controller?
    A: The dissolved oxygen meter can be compatible with DRFN digital dissolved oxygen sensors including fluorescence and polarography.


    2. How does your DO controller collect sensor data?
    A: The connected sensor uploads the detected data in a special encrypted communication method to ensure that the DUC controller can collect high-precision data more stably


    3. What are the applications of dissolved oxygen analyzers?
    A: Sewage/Surface water monitoring/Aquaculture water bodies/Urban sewage treatment/Industrial wastewater treatment /Aquariums

    Quality Digital Fluorescence Method 18~36VDC  Dissolved Oxygen Controller For Waste Water for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Dissolved Oxygen Analyzer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0