Sign In | Join Free | My burrillandco.com
Home > Other Electrical Equipment >

HD15 CPU Mainboard Ultrasonic Assy Imaging Center Device

    Buy cheap HD15 CPU Mainboard Ultrasonic Assy Imaging Center Device from wholesalers
     
    Buy cheap HD15 CPU Mainboard Ultrasonic Assy Imaging Center Device from wholesalers
    • Buy cheap HD15 CPU Mainboard Ultrasonic Assy Imaging Center Device from wholesalers

    HD15 CPU Mainboard Ultrasonic Assy Imaging Center Device

    Ask Lasest Price
    Brand Name :
    Model Number : HD15
    Price : Negotiable
    Payment Terms : T/T, Western Union
    Delivery Time : 2-4 work days
    • Product Details
    • Company Profile

    HD15 CPU Mainboard Ultrasonic Assy Imaging Center Device

    HD15 CPU Mainboard Ultrasonic Assy Healthcare Solutions Imaging Center Device

    HD15 CPU Mainboard Ultrasonic Assy


    1. Warranty: 60 days
    2. Condition: original and with good working condition

    3. Compatiable with HD15


    Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range.






    Other ultrasound parts related to that we can offer:


    BrandSystemDescription
    Envisorcontrol panel 453561184013
    EnvisorTR board M2540-20240 453561448371
    EnvisorRX/TX M2540-20040 REV C
    EnvisorAPIO 453561235651
    HD3back end board/mainboard BD-439-PCC
    HD3power board
    HD6power board
    HD7video board P381
    HD7keyboard control panel 453561194831
    HD7TR board M2540-60040F
    HD7LCD monitor 453561350091 454110240251
    HD7mainboard RB945G ATX Rev 1.0
    HD7mainboard M2540-60060
    HD7TI board M2540-60070 M2540-60270
    HD7 XELCD monitor
    HD9PSA board BD445PSA 0A
    HD9BF board BD-445-BF
    HD9MTR BD-445-MTR
    HD9TI board BD-445-PSA
    HD11/HD11XEfront end of TR board M2540-20240 back end M2540-60240
    HD11HD11 LCD monitor(not avaliable forHD7)
    HD11APIO 453561183003
    HD11XELCD monitor (19inch) 453561294281 (20inch)
    HD11XEPower 12NC 453561382672
    HD11XEvideo card PNY 9400GT 1025MB
    HD11/HD11XEpower board 453561161892
    HD11XEcontrol panel 453563495544 / 453563495542
    HD11/HD11XESP(signal processing board) 453561210154/453561343282 /453561343282,453561343281
    HD11/HD11XETR board 453561342481
    HD11/HD15Power Supply 4535-612-22772
    HD11/HD15video board 7300GS
    HD15touch screen
    HD15video card 69V02634T 69V02882T
    HD15ACB Assy ( acquisition control board) 453561197145/453561197144
    HD15AIM Assy 453561197306

    Knowledge point


    The solution of dealing with ultrasonic image interference


    1. Probe interference: replace the probe

    2. Equipment interference: replace the power supply or internal boards

    3. External interference:

    (1) Workstation interference: it is recommended to add several magnetic rings to the video cable, if it is not work, replace the ATX power supply, or add a filter to the host power input.

    (2) Power input interference: add several magnetic rings to the power line.


    If the above methods do not work, just try the method of eliminating the equipotentiality

    , adding a shielding cloth on the bed, and connect a wire to the ground strap of the machine.


    FAQ


    Q: How's the stock condition?
    A: Wide variety of Ultrasound probe/board, over 10,000 pcs in stock, involved in popular brands and systems(GE, Hitachi Aloka, Siemens,Toshiba, , Biosound---)



    Q: Is there any guarantee for the goods?
    A: Fully-tested and safe packing before shipping, less than 3% warranty return claims of previous orders.


    Q: Will you provide warranty?

    A: Items are sold with NO WARRANTY, unless it is stated otherwise in the body of the proforma invoice/purchase order. Mostly 90 days for new original, 30/60 days for used.


    Q: If faults occurred after warranty date, can I contact you?

    A: Sure, feel free to contact even years later. We'll look into the faults and try to find out some solutions/suggestions for you reference.


    Q: How do exchange proceed?
    A:The core/item for exchange must be complete and never repaired, and be sent to us after invoice approved.




    Quality HD15 CPU Mainboard Ultrasonic Assy Imaging Center Device for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Rongtao Medical Tech LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Ultrasonic Board products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0