Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner
Products Introduction Coolnet, with more than 30 years’ R&D and manufacturing experience in server room equipment field, depending on world-class labs, inspection and production equipment, not only can provide specialized products to meet the exact requirement of user’s job site, but also provide a perfect total solution for server room. Now our product range include precision air conditioner, UPS and data center solution. CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center. Benefits 
  | ![]()  | 
Applications
  |  Computer room and data center  Switch room and mobile center station in telecommunication  High-tech environment and lab  Industrial automation control room and precision manufacturing workshop  Standard test room and calibration center  UPS and battery room  Test room in hospital  Biochemical culture chamber  | 
Features
1. High quality control component. 2. Efficient evaporator made from advanced technology and with larger heat exchange area. 3. Danfoss brand quality expansion valve. 4. Internationally advanced electrode steam humidification system. 5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment. 6. G4 level air filter to guarantee the server room air purity. 7. Copeland hermetic scroll compressor. 8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional. 9. Highly efficient PTC electrical heater. 10. Anti-corrosion alloy condenser.  | ![]()  | 
Technical Parameters
| Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
| Power Supply | 380V 3Ph-50HZ | |||||||||||||
| Air Discharge | Upflow/Downflow | |||||||||||||
| Cooling Capacity :24℃/50%RH | ||||||||||||||
| Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 | 
| Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 | 
| AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 
| Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 | 
| Compressor Hermetic scroll | ||||||||||||||
| Refrigerant | R407C | |||||||||||||
| Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 
| Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
| Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 | 
| Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 | 
| Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 | 
| Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 | 
| Material | PTC | |||||||||||||
| Humidifier Section Electrode type | ||||||||||||||
| Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 
| Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 
| Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 | |