Sign In | Join Free | My burrillandco.com
Home > Air Conditioners >

Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger

    Buy cheap Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger from wholesalers
     
    Buy cheap Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger from wholesalers
    • Buy cheap Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger from wholesalers
    • Buy cheap Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger from wholesalers
    • Buy cheap Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger from wholesalers
    • Buy cheap Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger from wholesalers
    • Buy cheap Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger from wholesalers
    • Buy cheap Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger from wholesalers

    Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : SRF Series
    Certification : CE
    Payment Terms : T/T, Western Union
    Supply Ability : 50~100 units/ month
    Delivery Time : 40~45days
    • Product Details
    • Company Profile

    Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger

    Custom Commercial 50 Ton R410a Rooftop Package Central Air Conditioner

    Rooftop Ac Units​ Feature:
    Capacity: 12~36kw, 3.5~10Tons.
    Efficiency: 2.7~3.3 cop.
    Warranty: Compressor- 3 years limited. other parts-1 year limited.

    Structure
    Panels and frameMade from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
    CoilDirect expansion coils with condensate drain tray.
    Hermetic compressorHigh-efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber .
    Vibration damperRipple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.
    Centrifugal fanForward curve centrifugal fans for air treatment section and axial fans for condensation section. Front, side, and underside air discharge of the treatment unit. High external pressure, long air supply distance.
    Electric panelThe electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay, and other necessary protection devices for the main components.
    Easy operation line controllerCooling/Heating/Auto. Error indication. Timing on/off.
    Technical paramater:
    ModelSRF12ZASRF 15ZASRF18ZASRF24ZASRF30ZASRF35ZA
    SF12ZASF15ZASF18ZASF24ZASF30ZASF35ZA
    Nominal cooling capacitykW1215.217.52430.335.6
    Nominal heating capacitykW13.216.618.426.533.337.7
    Energy regulation%0,100%0,50,100%
    Power supply380V / 3Ph / 50HZA
    Cooling input capacitykW4.15.35.58.811.312.3
    Heating input capacitykW3.84.85.18.210.411.3
    Start currentA486263637476
    Cooling running currentA7.49.710.216.121.223.3
    Heating running currentA6.99.29.715.120.122.2
    Throttling methodThermal expansion valve
    Cooling system111122
    RefrigerantR410A
    CompressorTypeHermetic scroll compressor
    Qty111122
    Condensation side
    CondenserTypeCopper tube and aluminum fin
    Qty111111
    Drive typeDirect drive
    Motor powerkW0.250.370.370.550.750.75
    Air volumem3 /h46007800780090001260012600
    Evaporation side
    EvaporatorTypeCopper tube and aluminum fin
    Qty111111
    Motor powerkW0.320.370.451.11.52.2
    Air volumem3 /h210026003400410052006300
    Drive typeDirect drivePulley
    Static pressure(Pa)100100100200200250
    FilterAluminum filter G3
    Noise dB(A)676768717272
    Refrigerant filling volume(kg)3.13.14.32x3.12x3.12x4.3
    Overall dimensionsLength(mm)mm141014101410197819781978
    Width(mm)mm110011001100117511751175
    Height(mm)mm109510951095109510951095
    Weightkg240260290420480500
    Note:
    1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27℃/19℃ and outdoor DB/WB temperature is 35℃/24℃ condition;
    2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20℃/15℃ and outdoor DB/WB temperature is 7℃/6℃ condition;


    Application:
    Residential, office building, shopping mall...

    Packing:

    After-Sales Service:
    1. If the project needs our installation guidance, we can send our engineer and translator, but not free. We can also send customers installation video to teach them how to fix and operate with our product.
    2. Usually, our product warranty is 18 months after leaving factory or 12 months after installation. within this months, all parts broken will be responsible for our factory.













    Quality Commercial 50 Ton R410a Rooftop AC Unit With Fin Heat Exchanger for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Rooftop AC unit products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0