Sign In | Join Free | My burrillandco.com
Home >

Sectional Made Custom Design Flow Rate Trough Distributor

    Buy cheap Sectional Made Custom Design Flow Rate Trough Distributor from wholesalers
     
    Buy cheap Sectional Made Custom Design Flow Rate Trough Distributor from wholesalers
    • Buy cheap Sectional Made Custom Design Flow Rate Trough Distributor from wholesalers
    • Buy cheap Sectional Made Custom Design Flow Rate Trough Distributor from wholesalers

    Sectional Made Custom Design Flow Rate Trough Distributor

    Ask Lasest Price
    Brand Name :
    Model Number :
    Certification : ISO 9001
    Price : Negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 99 units per month
    Delivery Time : 3-5 days
    • Product Details
    • Company Profile

    Sectional Made Custom Design Flow Rate Trough Distributor


    Trough Liquid Distributor sectional - made custom design flow rate


    1. Trough liquid distributor introduction,


    Liquid distributor is the most important column internal from a process point of view. It is required to distribute liquid uniformly at the top of packing tower. Meanwhile a liquid distributor must have sufficient gas passage area to avoid high pressure drop or liquid entrainment.


    2. Choice of liquid distributor:


    Column Diameter

    mm

    Specific liquid load

    M3/m2*h

    System fouling tendencyTurndown ratioSuitable type of liquid distributor
    250 - 9000.75 - 5Low - medium<10:1

    Trough type liquid distributor with sump

    Deck type liquid distributor with orifices on drip tubes

    5 - 30Low - medium2:1

    Pan type liquid distributor

    Trough type liquid distributor with sump

    >30Low - medium2:1

    Pan type liquid distributor

    Trough type liquid distributor with sump

    Deck type liquid distributor

    >9000.75 - 5Low - medium<10:1

    Trough type liquid distributor with parting box

    Deck type liquid distributor with orifices on drip tubes

    5 - 30Low - medium2:1

    Trough type liquid distributor with sump

    Trough type liquid distributor with parting box

    Deck type liquid distributor

    >30Low - medium2:1

    Deck type liquid distributor

    Trough type liquid distributor with sump


    3. Liquid distributors usage:


    Column internals like liquid distributor play very important role in effective mass transfer performance. So they need to be designed carefully for both process and mechanical point. Meanwhile, the engineers put great effort into structured packing and random packing development in the recent years. The column internals include mist eliminators, feed pipes, distributors, re-distributors, support plates, bed limiters, collector trays, etc.


    4. How to choose liquid distributor?


    When we need to select a liquid distributor, we need to consider the tower diameter, flow rate, turndown ratio, available height (in case of revamp) and fouling resistance.

    Weir type gravity distributor:

    Generally speaking, the weir type gravity distributor is one of the least troublesome distributors. It has excellent trundown capability and can handle large liquid load. However it can usually provide only a limited number of drip points (minimum 30 number of weirs per m2). It is also extremely sensitive to levelness and liquid surface agitation.

    Orifice type gravity distributor:

    Usually it shows as pan type, deck type or tunnel (trough) type. An orifice pan distributor consists of a pan. There are circular or rectangular risers for vapor flow and perforation for liquid flow in the pan.

    Orifice trough type distributors consist of parallel troughs with perforated holes in the bottom for liquid flow. Vapor rises in the space between the troughs. The troughs are often interconnected by cross channels (called as parting box), which help equalize the liquid level in different troughs. This trough type liquid distributors provide more open area for vapor flow and is easier to support.

    Orifice type distributor can be designed to have a large number of drip points to provide superior liquid distribution, though it may suffer from corrosion and plugging. Orifices are sized to maintain a minimum liquid head at desired turndown conditions & to avoid distributor overflow during turn up condition. Very small orifice diameters (<4mm) are avoided to prevent fouling.


    5. Trough liquid distributor production



    Welcome your contact with your private tower internals plan or ideas!

    Quality Sectional Made Custom Design Flow Rate Trough Distributor for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Beijing Silk Road Enterprise Management Services Co.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Tower Internals products from this supplier
    Inquiry Cart 0