Sign In | Join Free | My burrillandco.com
Home > Prefab Houses >

20x50ft 2200m3/H Prefabricated Clean Rooms Class 10000 Modular Anlaitech

    Buy cheap 20x50ft 2200m3/H Prefabricated Clean Rooms Class 10000 Modular Anlaitech from wholesalers
     
    Buy cheap 20x50ft 2200m3/H Prefabricated Clean Rooms Class 10000 Modular Anlaitech from wholesalers
    • Buy cheap 20x50ft 2200m3/H Prefabricated Clean Rooms Class 10000 Modular Anlaitech from wholesalers
    • Buy cheap 20x50ft 2200m3/H Prefabricated Clean Rooms Class 10000 Modular Anlaitech from wholesalers

    20x50ft 2200m3/H Prefabricated Clean Rooms Class 10000 Modular Anlaitech

    Ask Lasest Price
    Brand Name : anlaitech
    Model Number : AL-MODULAR CLEAN ROOM
    Certification : CE , FAT, CLASS REPORT
    Payment Terms : L/C, T/T, Western Union
    Delivery Time : 12WORKING DAYS.
    • Product Details
    • Company Profile

    20x50ft 2200m3/H Prefabricated Clean Rooms Class 10000 Modular Anlaitech

    20*50ft Class 10, 000modular cleanrooms with Free Design


    FS209E Clean room contains six classes, while the ISO 14644-1 classification system adds two cleaner standards and one dirtier standard (see chart below). The "cleanest" cleanroom in FS209E is referred to as Class 1; the "dirtiest" cleanroom is a class 100,000. ISO cleanroom classifications are rated according to how much particulate of specific sizes exist per cubic meter (see second chart). The "cleanest" cleanroom is a class 1 and the "dirtiest" a class 9. ISO class 3 is approximately equal to FS209E class 1, while ISO class 8 approximately equals FS209E class 100,000.

    In November 2001, Federal Standard 209E was superseded by the new ISO 14644-1 international standards. References to FS209E are still used; the comparison chart below illustrates the relationship between the two standards.

    Anlaitech cleanroom walls are made of durable, easy-to-clean, ISO-grade materials, as specified in FDA guidance documents. Combined with your cGMP processes, they will help you comply with operational requirements.

    ISO 14644-1 standard Clean rooms

    ISO14644-1 is the most widespread modern cleanroom standard that not only defines the design of clean rooms, but also provides guidelines for implementation and use. Many manufacturers base their requirement system on ISO-14644:

    Classmaximum particles/m3 aFED STD 209E equivalent
    ≥ 0,1 µm≥ 0,2 µm≥ 0,3 µm≥ 0,5 µm≥ 1 µm≥ 5 µm
    ISO 110bdddde
    ISO 210024b10bdde
    ISO 31 00023710235bde1
    ISO 410 0002 3701 02035283be10
    ISO 5100 00023 70010 2003 520832d,e,f100
    ISO 61 000 000237 000102 00035 2008 3202931 000
    ISO 7ccc352 00083 2002 93010 000
    ISO 8ccc3 520 000832 00029 300100 000
    ISO 9ccc35 200 0008 320 000293 000Room air

    Technical Paremeters:

    ModelInner dimensionNumber ofAir volume(m3/h)Clean Class
    W * D * H (mm)FFU
    ALCS6 * 82000 * 3000 * 240066600ISO5
    ALCS 8 * 122440 * 3660 * 24001213200ISO5
    ALCS 8 * 162450 * 4880 * 24001617600ISO5
    ALCS 8 * 202440 * 6100 * 24002022000ISO5
    ALCS6 * 82000 * 3000 * 240022200ISO6
    ALCS 8 * 162440 * 4880 * 240044400ISO6
    ALCS 12 * 163660 * 4880 * 240066600ISO6
    ALCS 20 * 246100 * 7300 * 24001213200ISO6
    ALCS6 * 82000 * 3000 * 240011100ISO7
    ALCS 8 * 162440 * 4880 * 240022200ISO7
    ALCS 12 * 163660 * 4880 * 240044400ISO7
    ALCS 20 * 246100 * 7300 * 240088800ISO7
    ALCS16 * 244880 * 7300 * 240022200ISO8
    ALCS18 * 305480 * 9150 * 240044400ISO8
    ALCS20 * 426100 * 12800 * 240066600ISO8

    About Positive Pressure Clean room


    Cleanrooms are designed to maintain positive pressure, preventing "unclean" (contaminated) air from flowing inside and less-clean air from flowing into clean areas. The idea is to ensure that filtered air always flows from cleanest to less-clean spaces. In a multi-chambered cleanroom, for instance, the cleanest room is kept at the highest pressure. Pressure levels are set so that the cleanest air flows into spaces with less-clean air. Thus, multiple pressure levels may need to be maintained.


    A differential air pressure of 0.03 to 0.05 inches water gauge is recommended between spaces. In order to minimize disruptions to these cascading pressures when doors are opened, air locks are often specified between rooms of differing ISO cleanliness levels. Automated fan controls simplify pressure balancing by allowing fan speed adjustments at a centralized console panel.


    Quality 20x50ft 2200m3/H Prefabricated Clean Rooms Class 10000 Modular Anlaitech for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Anlai Airtech Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Clean Rooms products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0