0.02 Class 60A CT PT Test Equipment Low Current CT Test System
System Configuration
Low-Current CT Tester
Two-Stage Standard Current Transformer
CT Test Power source
Technical Parameter
Low-Current CT Tester (Bridge)
| Display: | LED | 
| Measure item: | Ratio errors & Phase errors of the low-Current CT | 
| Rated current: | 1mA, 2mA, 5mA, 20mA, 50mA | 
| Multiplier: | 0.5, 1, 1.5, 2, 3 | 
| Accuracy class: | ±2% | 
| Operation range: | (1%-200%).In | 
| Frequency: | 50/60Hz | 
| Ratio error range: | ±0.0001% ~ ±19.99%(Three positions: 1.999‰, 19.99‰, 199.9‰) | 
| Minimum resolution:0.0001%. | |
| Phase error range: | 0.01' ~ ±900'(three positions: 9.00', 90.0', 900') | 
| Minimum resolution: 0.01' | |
| Alarm Function: | Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent. | 
| Provided load for object CT: | 0Ω, 5Ω, 10Ω, 20Ω, 30Ω, 50Ω, 100Ω, 200Ω, 250Ω, 500Ω (COSφ=1.0) | 
| Input load on standard side: | 10Ω (COSφ=1.0) | 
| Communication Interface: | Provided the RS232 serial communication interface | 
| Power supply: | AC 220V±10% | 
| Power consumption: | < 20VA | 
Two-Satge Standard Current Transformer
| Frequency: | 50Hz/60Hz | 
| Primary Current (A): | 0.6,1,1.5,2.5,3,4,5,6,7.5,8,10,15,20,30,50,60 | 
| Secondary Current (mA): | 1, 1.5,2,2.5,3,10/3,4,5,20/3,7.5,8,10,15,50/3,20,25,30,100/3,50 | 
| Rated Current Ratio: | Arbitrary combination of Pri,Current and Sec.Current | 
| Accuracy Class: | 0.02% | 
| Operation Range: | (5%-300%).In | 
| Secondary Burden: | 10Ω | 
| Power Factor: | COSΦ=1.0 | 
| Voltage Level: | AC 600V | 
| Insulation: | Air | 
| Operating Condition: | Temperature: -5 oC ~ +40 oC | 
| Relative Humidity (RH): up to 85% (max 90%) | |
| Dimension (mm) : | 460x380x160 | 
| Weight ( kg ): | ~15kgs | 
CT Test Power Source
| Input Voltage: | AC 220V±10% 50/60Hz | 
| Output Current: | AC 5A, 50A, 100A | 
| Rated Capacity: | ~500VA | 
| Output Voltage: | Provided the Coarse adjustment & Fine adjustment | 
| Adjustment Model: | Manual adjustment | 
Feature
1) high accuracy and stability
2) specially used for test of low current CT
3) small size and weight, suitable for carrying
4) operation mode: manual
5) ratio error test, phase angle test, polarity test

Optional design for bridge
|   |