    Air Dust Proof Valve 3/4 " 1 " Pulse Jet Valve Pneumatic Two way Indsutry cement factory application

    Ask Lasest Price
    Brand Name : NBSANMINSE
    Model Number : QD - Z - 20 / 25
    Certification : ISO9001
    Price : Negotiation
    Payment Terms : L/C,T/T
    Supply Ability : 10000PCS
    Delivery Time : 5-30days
    • Product Details
    • Company Profile

    Air Dust Proof Valve 3/4 " 1 " Pulse Jet Valve Pneumatic Two way Indsutry cement factory application

    QD - Z - 20 / 25 Series Electromagnetic Pulse Vave GOYEN Replace Right Angle Air Dust Proof Valve 3 / 4 " , 1 "





    Usage


    Electromagnetic valve ( Also called diaphragm valve ) is the” switch “for compressed air in the dust clean blowing system of the pulse bag filter . Controlled by the output signals of the pulse jet control device , it makes dust clean to the filter bags cell by cell to keep the resistance of thebaghouse within the set range and thus guarantee the processing functions and the dust collecting efficiency of the baghouse .


    Z type electromagnetic pulse valves is a right angle valve , with the 90 degree , angle between the inlet and outlet , which is suitable for the installation connection between the gas dome and the baghouse blow tube provide good air flow and dust clean pulses satisfying the requirements .



    Working Principle


    The electrical signals from the pulse jet control device move the armature of the electromagnetic pulse valve . The air escape of the back gas cell opens and the back bag gas cell loses pressure quickly , thus the diaphragm moves back and the compressed air blows through the valve outlet . The electromagnetic pulse valve comes into the “open” condition .



    Material Construction


    BodyADC12 die cast
    Armature430FR stainless steel
    DiaphragmNitrile or viton
    Spring321 Stainless steel
    Fasteners302 Stainless steel


    Good Quality membranes shall be selected and used fo all the valves , with each part checked in each manufacturing procedure , and put into the assembly ling conforming to all the procedures . Every finished valve shall be taken the electriferous blowing test .



    Common failure and troubleshooting


    Use periodFailure phenomenaPossible ReasonTroubleshooting
    During installation and commissioningThe valves cannot all be opened, but the leading part does act.Check the gas dome pressure to see if it is too low.Check the leakage
    Some valves do not work, but the others are normal.Check the valve coil connection and coilReplace the accessories
    The valves cannot all be closed. There is leakage. There is no way to establish a gas dome.Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves.Check the leakage
    Z-valve. The valve inlet and blowing muzzle are installed backwards.Re-install
    Some valves cannot be closed. There is leakage.There is some dirt or debris on the membrane, ii is blocking the moving iron core.Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.
    A valve closing is slowly.The membrane orifice is blocked.Dredge the membrane orifice
    During use period

    Some valves are leaking. The membrane cannot close tightly and the valve is always open a

    little.

    There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked.Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.
    Coil is hot and burned out.It has been turned on for too long.Check the working condition of the control system.
    Voltage exists but the valve does not operate.Membrane is damaged and the orifice is blocked.Replace the accessories in time.
    Ambient temperature is below -20℃. The valve is leaking and cannot open.Ambient temperature is too low and here is frost in the valve.Pay attention to insulation and maintaining proper temperatures.




    Quality Air Dust Proof Valve 3/4 " 1 " Pulse Jet Valve Pneumatic Two way Indsutry cement factory application for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Ningbo Sanmin Import And Export Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Pneumatic Pulse Valve products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0