Sign In | Join Free | My burrillandco.com
Home > Water Treatment >

EO ETO Ethylene Oxide Sterilization Equipment For Low Temperature Sterilization

    Buy cheap EO ETO Ethylene Oxide Sterilization Equipment For Low Temperature Sterilization from wholesalers
     
    Buy cheap EO ETO Ethylene Oxide Sterilization Equipment For Low Temperature Sterilization from wholesalers
    • Buy cheap EO ETO Ethylene Oxide Sterilization Equipment For Low Temperature Sterilization from wholesalers

    EO ETO Ethylene Oxide Sterilization Equipment For Low Temperature Sterilization

    Ask Lasest Price
    Brand Name : Medpharm
    Model Number : SQ-HV
    Certification : ISO
    Price : According to size
    Supply Ability : 20 units per month
    Delivery Time : 20 work days
    • Product Details
    • Company Profile

    EO ETO Ethylene Oxide Sterilization Equipment For Low Temperature Sterilization

    EtO Sterilization Cycle

    There are at least three stages in a typical EtO sterilization cycle:

    • Preconditioning
    • Sterilization
    • Aeration (Degassing)

    Cycle time is usually more than 14 hours.

    Preconditioning

    Preconditioning prepares the chamber environment to meet the ideal conditions for temperature, pressure and humidity. First air is removed from the chamber to allow for gas penetration. A leakage test is performed, to ensure that staff and environment are safe. Next, some steam is injected into the chamber and humidifies the load, since EtO is only effective in a humid environment. The chamber is heated by either steam or hot water which is present in the jacket. Normally the jacket is kept at the same temperature 24/7 to minimize temperature fluctuations.

    Sterilization

    The second stage is the actual sterilization process. The EtO enters the chamber via evaporation with a certain amount of steam to keep the humidity level up as well as to make sure the EtO is reaching all parts of the load. When the required concentration in the chamber and load is achieved the actual sterilization stage starts. The lower the gas concentration in the chamber the longer is the sterilization time. As EtO is absorbed by many kinds of plastic materials it is important to keep the concentration at the right level. To achieve this EtO is sometimes added to the chamber after a while. It is of major importance to ensure the appropriate concentration level of EtO in the chamber to achieve effective and safe sterilization.

    Aeration (Degassing)

    Aeration is the most important and longest part of the EtO sterilization cycle. As mentioned, materials such as plastics and rubbers absorb gas and if applied to patients, the toxic gas could damage their body tissue! For this reason it is very important to have an excessive aeration stage to remove any remaining EtO gas and to allow absorbed gas to evaporate again from the sterilized items. This is done by circulating HEPA filtered air over the load at a temperature of 30°C to 50°C. This is sometimes done in the sterilizer’s chamber, but sometimes the sterilized items are placed in a special aeration cabinet. If the sterilized items are repositioned from the chamber to the aeration cabinet then strict safety precautions should be in place to prevent EtO gas exposure to the people who perform this function. A commonly used time period for this aeration treatment is 48 hours which results in a very slow instrument turnaround. A special infrastructure is required, with gas tight ventilation piping to the roof top or to a catalyzer. The sterilizer cannot use the hospital's ventilation system because it is too dangerous. The special ventilation piping has to be tested for gas leaks all the way as this is the only way to minimize the risks.

    There are some advantages however. An EtO sterilizer can have a very large chamber, even up to 7m³. They are often used for the sterilization of large quantities of products that cannot be sterilized by steam. When gauze or non-woven materials like disposable gowning are manufactured they need to be sterilized before entering the hospital. These are often sterilized by EtO because steam will damage or deform these materials.

    To summarize, EtO sterilization should be used only when another method is not appropriate.


    Advantages of EtO are:

    • Low temperature
    • High efficiency – destroys microorganisms including resistant spores
    • Large sterilizing volume/ chamber capacity
    • Non corrosive to: plastic, metal and rubber materials

    Disadvantages are:

    • Excessively Long cycle
    • Safety concerns - carcinogenic to humans
    • Toxicity issues - toxic residues on surgical instruments and tubing
    • Not recommended for flexible scope
    • EtO is flammable
    • Requires special room conditions, safety equipment and separate ventilation system
    • Relatively high annual costs for maintenance, servicing and consumables

    Technical parameter

    Rated pressure0.1MPASteam supply pressure0.15-0.6MPA
    MAX working pressure0.05MPACooling water pressure0.15-0.3MPa
    Rated temperature100°CCompressed Air Pressure0.4-0.6MPa
    Max working temperature37-55°CControl power220V AC/0.5KW
    Motor power380V AC/6KW

    Item and TypeSQ-H120VSQ-H220V
    Appearance size(W×H×D)1000*1850*800mm1000*1850*1100mm
    Inner chamber size(W×H×D)450*400*750mm520*500*800mm
    Inner chamber volume120220
    Power supply220V(110V);50(60)HZ220V(110V);50(60)H
    Power3KW3.3 KW
    Outside packing materialstainless steel/Q235plastic spraystainless steel/Q235 plastic spray
    Inner chamber materialSUS304SUS304
    Water storage capacity of the humidifying bottle600 mL600 mL
    Exhaust condition1/2″ stainless steel tube (SUS304)1/2″ stainless steel tube (SUS304)
    Weight200KG220KG
    Sterilization cycle ( all)55℃:3 hours 30 minutes55℃:3 hours 30 minutes
    37℃:5 hours 30 minutes37℃:5 hours 30 minutes
    Quality EO ETO Ethylene Oxide Sterilization Equipment For Low Temperature Sterilization for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: ZHANGJIAGANG MEDPHARM MACHINERY LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more ETO Sterilization Machine products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0