    Brand Name : ESTEL
    Model Number : DDTE016
    Certification : ISO9001, CE, 3C, FCC, TLC, IP55
    Price : 358-2143 usd
    Payment Terms : L/C,D/A,T/T, Western Union, Paypal, etc
    Supply Ability : 6,000 sets per month
    Delivery Time : 10-15 working days
    • Product Details
    • Company Profile

    Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System


    Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System


    Quick Details


    Place of Origin: Shenzhen, China (Mainland)External Size H×W×D 2100×1600×800mm
    Brand Name: ESTELStructure: sandwich structure, double wall, with insulation .
    Model Number: DDTE016Cabinet Layout: two compartments
    Product Name: base station cabinetCabinet Lock: anti-theft three point lock
    Certification: ISO9001, CE, 3C, FCC, TLC, IP55Protection Level: IP55
    Application: outdoor telecom base stationCable Entry: at cabinet bottom
    Material: galvanized steelIllumination: DC48V LED lamp
    Heat Insulation: PEFGrounding Protection: copper bar
    Color: grey (support custom made)Cooling: peltier air conditioner and heat exchanger
    Coating: anti-corrosion outdoor powder coatingAccessories Options: PDU, rectifier system, environment monitoring system

    Payment & Shipping Terms


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C,D/A,T/T, Western Union, Paypal, etc
    Supply Ability:6,000 sets per month
    Delivery Time:10-15 working days
    Packaging Details:wooden case

    1. Specifications

    (1) Technical Parameters


    ItemTypeTechnical Parameter
    StructureDimensionExternal Size H×W×D 2100×1600×800mm
    LayoutTwo compartments
    Equipment Installation Method19” standard rack
    DoorWith two front doors, and anti-theft three point lock for outdoor cabinet (support padlock)
    Material

    1.Galvanized steel;

    2.Double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with 20mm heat insulation between two walls.

    StructureAssembled
    Ingress ProtectionIP55
    Temperature ControlCoolingpeltier air conditioner and heat exchanger
    LightingLED lamp48V LED lamp
    TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
    Storage Temperature: -50°C ~ + 70°C
    Transport Temperature: -50°C ~ +70°C
    HumidityRelative Humidity5% ~ 100%
    PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
    Radiation IntensitySolar Radiation Intensity1124 × (1±5%)W/m2

    Accessories List


    No.ItemQuantityUnitSpecs
    1Two Compartments Outdoor Telecom Cabinet1SetExternal Dimension: H×W×D 2000×1600×800mm
    2Peltier Air Conditioner1Set

    Cooling Capacity: 200W

    Power Supply: DC48V

    3Heat Exchanger1Set

    Heat Exchange Capacity: 80W/K

    Power Supply: DC48V

    4Rectifier System1SetDC48V, 120A
    5Power Distribution Unit1Set

    Grade B Lightning Proof

    AC Input: 63A/2P *1;

    AC Output: 16A/1P*4;

    DC Output: 16A/1P*4.

    Height: 4U

    6Environment Monitoring Unit1Set
    7Temperature and Humidity Sensor2PC
    8Door Sensor4PCTwo for controlling LED lamp on/off, the other two for door open alarm
    9Water Sensor2PC
    10Smoke Sensor2PC
    11LED Lamp2PCDC48V
    12Package1SetWooden Case

    2. Description


    The DDTE016 Outdoor Integrated Telecom Enclosure is mainly used in wireless communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.

    The cabinet, made of galvanized steel, is divided into equipment compartment and battery compartment. The right part of the cabinet is equipment compartment, which is separated from the battery compartment for heat insulation of the equipment space. The battery compartment is used for installing batteries. The cabinet body has heat insulation foam, which can keep the temperature inside the cabinet. The cabinet also has roofs which is sun proof and water proof. There’re ventilations for releasing harmful gas generated by the batteries.

    The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock. There’s open door alarm sensor, which works together with the environment monitoring unit.


    3. Features


    • The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment. The protection level is IP55.
    • Three cooling for the cabinet: heat exchanger ,air conditioner and fans-.
    • -48V lamp is installed inside the cabinet.
    • The cabinet is installed with Environment Monitoring Unit, door alarm, temperature and humidity sensor, smoke sensor, water sensor etc., which can work together to monitor the inside environment of the cabinet.
    • The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There’re entrance holes individually for power cable, signal cable and optical cable.
    • All the cables used in the cabinet are made from flame retardant materials.

    4. Cabinet Structure

    4.1 Door and Door Limit


    (1) Cabinet door options: vertical hinge door, horizontal hinge door.

    (2) The door limit device can limit the door position when it is open.

    (3) The door limit function is automatically activated when the door is open, and should be canceled manually when the door is closed



    When the door is fully opened, the largest open angle is larger than 95°. If it is horizontal hinge door, it can prevent outside water from flowing into the equipment compartment from the upper side. The bottom edge of the door limit device is higher than the hinge level, which can offer enough operating space.


    (5) After 1000 times open and close operation, the door and door device will have good function and have no excessive wear and tear.

    (6) At the door limit status, the door limit device can bear the static load by door opening and closing at 22m/s wind, without mechanical failure and function failure.


    4.2 Grounding


    The cabinet include grounding copper bar, 4mm thick, with 10×M6 flare-in nuts, 2×M8 flare-in nuts, 2×M10 flare-in nuts. The grounding bar is nickel plated. The screw is made from copper bar and with passivation surface treatment.



    4.3 Theft Proof Design

    • Theft proof lock


    • Three point lock


    4.4 Cable Entry


    Feeder cable and other external cables all use bottom wiring method.



    4.5 Appearance and Surface Treatment


    Outdoor powder coat, with gray color. The coat is anti-shock, anti-aging, anti-solvent, anti-low temperature.


    5. Electrical Technical Parameters

    5.1 Monitoring System Diagram and Solution


    Monitoring alarm


    The monitoring unit conducts real time monitoring on smoke, water, door opening, LED lamp, temperature and humidity inside each compartment through various sensors. It is with alarm output, and can transmit alarm signals to Local Area Network or remote monitoring platform through RS485/RS232, Ethernet etc.


    Monitoring Unit Diagram



    The monitoring unit uses dual core processing. the power supply uses DC/DC module. The measuring channel, power supply, and communication interfaces are electrically isolated, so the monitoring unit has high reliability . The MCU control design has functions of self management and self correction. The monitoring unit support RS485/RS232 communication method. With the communication interfaces, it can realize many kinds of communication modes, such as point to point communication, point to multipoint communication, wireless remote communication, which can meet the need of various system networks.


    5.2 Monitoring and Alarm


    The monitoring unit conducts the following monitoring and alarm for the cabinet: door alarm, power failure alarm, smoke alarm, water alarm, temperature and humidity detection and alarm, shock and tilt alarm, etc.


    Door alarm


    There are two door switches. The one near the top of the cabinet is used for control the on/off of LED lamp, and the other one detects the opening and closing of the cabinet door. When the door is open, the door switch closes, and the monitoring unit will transmit the alarm to the control center through RS485/RS232. Meanwhile, there is correlative alarm dry contact output (port AL6, AL7). It will close in abnormal situation.


    Power failure alarm


    The port “AC220V” on the monitoring unit is for utility power detecting input. In case of utility power failure, the monitoring unit will transmit the alarm signal to the control center through RS485/RS232, and there is correlative alarm dry contact output (port AL8, AL9). It will close in abnormal situation.


    Smoke alarm


    The port “S” on the monitoring unit is for smoke sensor detecting input. When smoke is detected, the red light on the smoke sensor turn bright, the monitoring unit will transmit the alarm to the control center, and there is correlative alarm dry contact output (port AL2, AL3). It will close in abnormal situation.


    Water alarm


    The port “w+. w-” on the monitoring unit is for water sensor detecting input. When water is detected inside the cabinet, the monitoring unit will transmit the alarm to the control center, and there is correlative alarm dry contact output (port AL4, AL5). It will close in abnormal situation.


    Temperature and humidity detection and alarm


    The port “5V, T1, H1, GND” on the monitoring unit is for temperature and humidity sensor of battery compartment detecting input, and port “5V, T2(or T3), H2(or H3), GND” is for temperature and humidity sensor of equipment compartment detecting input. The monitoring unit can conduct real time detecting on temperature and humidity inside the compartment. When temperature and humidity sensor send out alarm signal, the monitoring unit will transmit the alarm signal to the control center, and there is correlative alarm dry contact output (port AL0, AL1). It will close in abnormal situation.


    5.3 Technical Parameters of Monitoring Unit and Sensors

    Environment Monitoring Unit


    • 19”, 1U, power supply DC48V/AC220V
    • Communication mode: RS232/RS485
    • 8 analog inputs. 4 specially for temperature and humidity detecting, the other 4 for general analog detecting, universal input.
    • 13 switch DI inputs, the port function can be redefined through programing.
    • 14 switch DO outputs, the port function can be redefined through programing.
    • LCD display, user friendly


    Door Alarm


    (1) Technical Parameters:

    Contact power: ≤10W

    Voltage: ≤28VDC

    Current: ≤0.5A

    Contact impedance: ≤300mΩ

    Action distance: 35mm

    Fixing mode: embedded

    Safety standard(UL):94-HB


    Function:

    When forcible entry (forcible opening the cabinet door) happens, the door sensor will send the door alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



    Power Failure Alarm


    Technical Parameters:

    Coil voltage: AC220V

    Power: ≤0.1W


    Working temperature: -20°C ~ 70°C

    Working humidity: 0% ~ 95%

    Communication mode: contact output


    (2) Function:

    When AC power supply failure happens, the sensor will send AC power supply failure alarm signal, and transmit the alarm signal to the monitoring center in switching mode.


    Smoke Sensor


    Technical Parameters:

    Voltage: 5-24 VDC

    Power: ≤1W

    Working temperature: -20°C ~ 70°C

    Working humidity: 0% ~ 95%

    Communication mode: contact output


    Function:

    When burning or smoke happens inside the cabinet, the sensor will send out alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



    Water Sensor


    (1) Technical Parameters:

    Voltage: 5-15 VDC

    Power: ≤0.5W

    Alarming water level: 5mm

    Working temperature: -20°C ~ 70°C

    Working humidity: 0% ~ 95%

    Communication mode: contact output


    Function:

    When water level inside the cabinet reach the alarming level, the sensor will send out alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



    Temperature Sensor


    (1) Technical Parameters:

    Voltage: +5VDC

    Power: <0.5W

    Temperature error: ±0.2°C

    Temperature resolution: 0.0625°C

    Working temperature: -50°C ~ 120°C

    Working humidity: 0% ~ 95%

    Communication mode: monobus


    (2) Function:

    When temperature inside the cabinet exceed the set range, the sensor will send out high temperature or low temperature alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



    Temperature Control Failure Alarm


    (1) Technical Parameters:

    Voltage: +5VDC

    Power: <0.5W

    Temperature error: ±0.5°C

    Temperature resolution: 0.0625°C

    Working temperature: -50°C ~ 120°C

    Working humidity: 0% ~ 95%

    Communication mode: monobus


    (2) Function:

    When temperature control device fails, the sensor will send out temperature control device failure alarm signal, and transmit the alarm signal to the monitoring center in switching mode.


    6. Protection


    The cabinet is corrosion proof, water proof, dust proof, condensation proof, wind proof, lightening proof. The protection level is IP55.


    7. Lighting and other specs


    (1) The working voltage of the lamp is -48VDC or 220VAC.

    (2) LED lamp can turn on or turn off intelligently. When the cabinet door is open, the LED will turn on automatically. When the cabinet door is closed, the LED will turn off automatically.

    Displacement sensor for detecting cabinet door. When the door is open, it pops up and at close circuit situation.



    (3) The cabinet includes 220V power socket.

    (4) The MDF compartment and equipment compartment have document holders.

    (5) The service life of the cabinet sealing strip is longer than 10 years, and is easy for replacement.


    8. Packing and Shipping



    Our Delivery Agent


    The goods can be shipped by sea, by air, by courier, by land, by train, etc.

    Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


    9. Our Contact Information


    Mobile Phone: 0086-13752765943

    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10

    Quality Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Base Station Cabinet products from this supplier
    Inquiry Cart 0