| Sign In | Join Free | My burrillandco.com | 
 | 
| Ask Lasest Price | |
| Brand Name : | JH | 
| Certification : | CE | 
| Model Number : | S-35-15 | 
| Payment Terms : | T/T, Paypal, Western union | 
| Supply Ability : | 30000pcs per month | 
Single Output LED switching power supply 35W 15V 2.4A Transformer AC to DC Converter
Features:
1. Reliable quality and good price
2. High efficiency and low working temperature
3. Built-in EMI filter
4. 100% full-load burn-in test
5. Protection: Over load protection, short circuit protection
Specification:
| Model number | S-35-5 | S-35-12 | S-35-15 | S-35-24 | 
| DC Output Voltage | 5V | 12V | 15V | 24V | 
| Output Voltage Error | ± 2% | ± 1% | ± 1% | ± 1% | 
| Rated Output Current | 7A | 3A | 2.4A | 1.5A | 
| Output Current Range | 0-7A | 0-3A | 0-2.4A | 0-1.5A | 
| Ripple and Noise | 100mVp-p | 75mVp-p | 75mVp-p | 50mVp-p | 
| Inlet Stability | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | 
| Load Stability | ± 1% | ± 0.5% | ± 0.5% | ± 0.5% | 
| DC Output Power | 35W | 36W | 36W | 36W | 
| Efficiency | 70% | 76% | 78% | 78% | 
| Adjustable Range for DC Voltage | +10%, -5% | ± 10% | ± 10% | ± 10% | 
| AC Input Voltage Range | 85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC | |||
| Input Current | 0.8A/115V 0.45A/230V | |||
| AC Inrush Current | Cold-Start Current: 18A/115V, 36A/230V | |||
| Leakage Current | <0.5mA/240VAC | |||
| Overload Protection | 105%~150% Type: Cut Output, Reset: Auto Recovery | |||
| Over Voltage Protection | .......... | |||
| Temperature Coefficient | ± 0.03% /°C (0~50°C) | |||
| Start, Rise, Hold time | 200ms, 100ms, 30ms | |||
| Vibration | 10~500Hz, 2G 10min, /1 cycle, a total of 60 minutes, Each axes | |||
| Withstand Voltage | Input and Output Interval: 1.5KVAC, Input and Enclosure: 1.5KVAC, Output and Enclosure: 0.5KVAC | |||
| Isolation Resistance | Input and Output Interval: Input and Enclosure, Output and Enclosure: 500VDC/100M Ohms | |||
| Working Temperature and Humidity | -10°C~+60°C (Refer to Output Derating Curve), 20%~90%RH | |||
| Dimension | 129*98*38 mm | |||
| Weight | 0.4kg | |||
| Safety Standards | Meet UL 1012 requirement (Not apply for the mark) | |||
| EMC Standards | Meet FCC Part 15J Condition class B | |||
1. The testing condition for the parameter above is: 230VAC input,
rated load, 25°C 70%RH, Humidity .
2. Error, include the setting error, line stability and load
stability.
3. Wave test: adopting "A12" twisted pair wire for 20MHz, and
0.1uF-47uF capacitor short-circuit for interrupting .
4. Inlet Voltage Stability test: when it is over load, the lowest
voltage of inlet is representative to the highest voltage .
5. Load stability test: the load is from 0% to 100% .
Dimension unit:mm
|   | 