Sign In | Join Free | My burrillandco.com
Home >

220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System

    Buy cheap 220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System from wholesalers
     
    Buy cheap 220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System from wholesalers
    • Buy cheap 220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System from wholesalers
    • Buy cheap 220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System from wholesalers
    • Buy cheap 220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System from wholesalers
    • Buy cheap 220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System from wholesalers
    • Buy cheap 220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System from wholesalers

    220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System

    Ask Lasest Price
    Brand Name : BRANDO
    Model Number : CA25T
    Certification : CE
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : 300 pcs per day
    Delivery Time : Negotiation
    • Product Details
    • Company Profile

    220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System

    Goyen Type T Series CA25T 220/240V AC Voltage Dust Collector Baghouse Cleaning System Application Pneumatic Pulse Valve


    CA25T Pulse Valve Diaphragm/Solenoid Activation

    Dust Collector Pulse-Jet Valve Operating Sequence:

    1. Differential pressure (DP) builds across the filter bags/cartridges as dust load increases in the collector.

    2. Once DP reaches a pre-set point, the pulse-jet cleaning system is activated to go through a cleaning sequence/cycle, as programmed in the timer board or other controller.

    3. The timer board (or other controller) then sends an electrical signal to the pilot solenoid valve(s), causing the coil to energize, thus pulling the valve plunger into the open position allowing the compressed air in the pneumatic line to bleed to atmosphere. (NOTE: The pilot solenoid valve can be direct-mounted (mounted directly on top of the diaphragm valve, or it can be remote-mounted (mounted in a solenoid enclosure separate from the diaphragm and connected with pneumatic tubing, as shown above.)

    4. Bleeding the compressed air line to atmosphere causes an imbalance in air pressure within the diaphragm valve. In other words, the air pressure suddenly drops on the top-side of the diaphragm valve as the pneumatic line is bled to atmosphere.

    5. The change in pressure difference within the diaphragm valve causes the compressed air manifold (compressed air tank) to force the diaphragm up from its seat, thus allowing compressed air to bypass the diaphragm and be expelled into the blow-tube. The “pulse” of compressed air then blows the dust off of the filter bags/cartridges.

    6. The coil is quickly de-energized which causes the plunger to return to the closed position. Compressed air then bleeds through the diaphragm valve until the point where pressure is equalized on both sides of the diaphragm. Equalization of air pressure inside the diaphragm causes the diaphragm to reseat (return to closed position). The pulse cycle is then completed.


    Pulse Cleaning System Components


    Diaphragm Valve CA25T Operation:


    Mechanical Details of Goyen Type Pulse Valve CA25T:

    No.DescriptionStandard material
    1Body and CoverAluminium die cast CA313
    2Bleed pinTurned aluminium
    3Diaphragm ass'yBuna N / Buna N Rubber
    4Springs304 stainless steel
    5Screws304 stainless steel
    6O ringsBuna N / Nitrile
    7Plunger Ass'y430 FR stainless steel
    8Ferrule / Iron top ass'y305 stainless steel
    9Coil arrgmnt130 rated nylon encapsulation
    10washerpressed aluminium
    11clipmechanical plated steel

    Pulse Valve CA25T Dimensions:


    Pulse Valve C25T Installation:
    1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
    2. Ensure tank and pipes are free from dirt, rust or other particulate.
    3. Ensure supply air is clean and dry.
    4, Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
    5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
    6. Apply moderate pressure to system and check for installation leaks.
    7. Fully pressurise system.
    8. Test fire and listen for proper actuation and crisp pulse noise.

    Quality 220 / 240v Ac Pulse Jet Valves For Dust Collector Baghouse Cleaning System for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Ningbo Brando Hardware Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Pulse Jet Valve products from this supplier
    Inquiry Cart 0