| Function | | DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V | | Basic accuracy | 0.025% | | AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V | | Basic accuracy | 0.4% (True-RMS) | | DC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A | | Basic accuracy | 0.05% | | AC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A | | Basic accuracy | 0.6% (True-RMS) | | Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) | | Basic accuracy | 1.0% | | Resistance | Range / resolution | 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ,
500.0 MΩ | | Basic accuracy | 0.05% | | Capacitance | Range / resolution | 1.000 n, 10.00 nF, 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF,
10.00 mF, 100 mF | | Basic accuracy | 1.0% | | Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz | | Basic accuracy | 0.005% | | Connectivity | Optional infrared connector via Fluke ir3000 FC | | General Specifications | | Maximum voltage between any terminal and earth ground | 1000 V | | Battery type | 6 AA alkaline batteries, NEDA 15A IECLR6 | | Battery life | 100 hours minimum, 200 hours in logging mode | | Temperature | Operating | -20°C to 55°C | | Storage | -40°C to 60°C | | Relative humidity | 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to
55°C) | | Electromagnetic compatibility | EMC EN61326-1 | | Vibration | Random vibration per MIL-PRF-28800F Class 2 | | Shock | 1 meter drop per IEC/EN 61010-1 3rd Edition | | Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | | Weight | 870.9 g (28 oz) | | Multiple on screen displays | Yes | | True-RMS AC bandwidth | 100 kHz | | dBV/dBm | Yes | | DC mV resolution | 1 μV | | Megohm range | Up to 500 MΩ | | Conductance | 50.00 nS | | Continuity beeper | Yes | | Battery/fuse access | Yes/Yes | | Elapse time clock | Yes | | Time of day clock | Yes | | Min-max-avg | Yes | | Peak | 250 μs | | Duty cycle | 0.01% to 99.99% | | Pulse width | 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms | | Hold | Yes | | Isolated optical interface | Yes | | Auto/touch hold | Yes | | Reading memory | Yes | | Log to PC | Yes | | Interval/event logging | Yes | | Logging memory | Up to 10,000 readings | | Wireless connectivity (optional) | Yes |
|