| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | KAIXIANG |
| Model Number : | 400KW |
| Certification : | ISO9001 |
| Price : | negotiable |
| Payment Terms : | Western Union, MoneyGram, T/T |
| Supply Ability : | 100 SETS ONE MONTH |
| Delivery Time : | ONE MONTH AFTER GET DEPOSIT |
400Kw Resistive Load Bank color Choose For Generator Testing
Product Description
AC400-400kW Intelligent Load Bank is mainly used to test the performance of generator. It can provide scientific monitor measure for generating set equipment.
Technical Parameter
| Rating Voltage/Frequency | 380VAC/50Hz, 3 phase 4 wire, line voltage 400V, phase voltage 220V |
| Rated Power | Resistive load: 410kW |
| Installed Capacity | Resistive load: 410kW |
| Load Step | 1,2,2,5,10,20,20,50,100,200kW, min step load: 1kW |
| PF(Power Factor) | 1 |
| Load Tolerance(each step) | ±5% |
| Load Tolerance(overall) | ±3% |
| Display Precision | 0.5 class |
| Control Power | 380VAC 50Hz |
| Wire Connection | Load power supply input——Copper bar (star coupling “Y”) Control power supply input——Connector-bar |
| Insulation | F |
| Way of Working | Continuous Working |
| Casing Dimensions and Cooling | about 1255mm×1530mm×1700mm (length*width*height) Forced air cooling,Horizontal inlet air and vertical cooling |
| Weight | About 600kgs/set |
| Transportation | Hoisting, there are lifting lug in top of casing, also the wheel casters can be provided |
| Casing Color | Grey(RAL7035)or as you required |
| Workplace | Outdoor |
| Ambient Temperature | -10℃~+50℃ |
| Relative Humidity | ≤95% |
| Altitude | ≤2500 meter |
| Atmospheric Pressure | 86~106kPa |
| Contactor | Schneider |
| Fuse | DELIXI |
| MCU | INFINEON |
| Data processing software | Kaixiang(self-developed) |
| Alloy Resistance | Kaixiang(self-developed) |
Product Advangent
(1) Communication Mode:RS485/ USB or RS232 interface for communication.
(2) Load Mode: manual load or automatic load
(3) Manual Load: input power and power factor, and load according to the preset value.
(4) Automatic Load: set several load stages and duration, then complete the process according this stages automatically. 0%- 25%,- 50%,- 75%, -100%
Application:
It is used with Engine Generators, Battery Systems, UPS Systems, Inverters, Ground Power Units, Auxiliary Power Units, Aircraft Power Generators, Wind Generators, and Hydro Generators

|