Sign In | Join Free | My burrillandco.com
Home > Industrial Controls >

Allen Bradley 1756-IF6I /A 1756-1F61 ControlLogix Input Current/Volt 6P

    Buy cheap Allen Bradley 1756-IF6I /A 1756-1F61 ControlLogix Input Current/Volt 6P from wholesalers
     
    Buy cheap Allen Bradley 1756-IF6I /A 1756-1F61 ControlLogix Input Current/Volt 6P from wholesalers
    • Buy cheap Allen Bradley 1756-IF6I /A 1756-1F61 ControlLogix Input Current/Volt 6P from wholesalers

    Allen Bradley 1756-IF6I /A 1756-1F61 ControlLogix Input Current/Volt 6P

    Ask Lasest Price
    Brand Name : AB
    Model Number : 1756-IF6I
    Certification : CO.CQ
    Price : inquiry
    Payment Terms : T/T
    Supply Ability : 10 pieces a day
    Delivery Time : today
    • Product Details
    • Company Profile

    Allen Bradley 1756-IF6I /A 1756-1F61 ControlLogix Input Current/Volt 6P


    Miya(manager)
    Email:miya@mvme.cn
    Skype:miyazheng520
    QQ :2851195450
    Tel:0592-5087576
    86-18020776792







    Product Name: AB 1756-IF6I

    General Specifications





    This mode lets you change the data representation of the selected module. Although the full range of the module does not change, you can scale your module to represent I/O data in terms specific for your application. For example, if you are using the 1756-IF6I module in floating point mode and choose an input range of 0 mA…20 mA, the module can use signals within the range of 0 mA…21 mA but you can scale the module to represent data between 4 mA…20mA as the low and high signals in engineering units
    The key difference between choosing integer mode or floating point mode is that the integer is fixed between -32,768…32,767 counts and floating point mode provides scaling to represent I/O data in specific engineering units for your application. Module resolution remains constant between the formats at 0.34 μA/count.
    This alarm feature detects when the isolated input module is operating beyond limits set by the input range. For example, if you are using the 1756-IF6I module in the 0…10V input range and the module voltage increases to 11V, the overrange detects this condition. The table lists the input ranges of the 1756-IF6CIS and 1756-IF6I modules and the lowest/highest signal available in each range before the module detects an underrange/overrange condition.

    Non-isolated Analog Voltage/Current Input Modules (1756-IF16, 1756-IF8)
    The 1756-IF16 and 1756-IF8 modules support these wiring methods: • Single-ended Wiring Method • Differential Wiring Method • High-speed Mode Differential Wiring Method After determining the wiring method you plan to use on your module, you must inform the system of that choice when you choose a Communication Format.


    For example, if you set the 1756-IF16 module (with normal scaling in volts) to a rate alarm of 1.0 V/S, the rate alarm only triggers if the difference between measured input samples changes at a rate > 1.0 V/S. If the module’s RTS is 100 ms that is, sampling new input data every 100 ms) and at time 0, the module measures 5.0 volts and at time 100 ms measures 5.08 V, the rate of change is (5.08V - 5.0V) / (100 mS) = 0.8 V/S. The rate alarm does not set as the change is less than the trigger point of 1.0V/s. If the next sample taken is 4.9V, the rate of change is (4.9V…5.08V)/ (100 mS)=-1.8V/S. The absolute value of this result is > 1.0V/S, so the rate alarm sets. Absolute value is applied because rate alarm checks for the magnitude of the rate of change being beyond the trigger point, whether a positive or negative excursion.






    Related products

    ABBIMMPI01BACHMANNDIO264
    ABBDSQC541BACHMANNDIO248
    ABBDSMB144BACHMANNCM202
    ABBDSBC 173BACHMANNMC205
    ABBBRC-100 P-HC-BRC-10000000BACHMANNDIO232
    ABB3BDS008790R09BACHMANNSEM201









    Our advantages:

    Industrial automation spare parts failure often causes tens of thousands of business losses to the enterprise.Moore LIMITED is the world's leading provider of high quality industrial automation
    spare parts, whether it is a new spare parts, or outdated / discontinued parts, and the technology is dedicated to the normal operation of the enterprise at the best cost, the best quality and
    efficient way.Whether it is customer service, work efficiency or delivery speed, we always strive for excellence and to be better and better.








    If you have any question pls do not hesitate to contact us.We can supply all kind of the automaiton parts,if you want to purchase parts pls send the parts model to my mail, I will prompt reply

    you asa I receive the mail.Hope anyone enquire from us.

    Waiting for your inquiry.





































































    Quality Allen Bradley 1756-IF6I /A 1756-1F61 ControlLogix Input Current/Volt 6P for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: MOORE AUTOMATION LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Allen Bradley Modules products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0